Updating scope-to-analysis specification associations
To update a scope-to-analysis specification association:
- From the main menu, click Administration views > RTA system availability monitoring > Specifications.
- From the Specifications tabular view (APSPEC object), click the Record check box beside the specification you want to change and click the Add to CICS system... button. The Add to CICS system view is displayed.
- Change the following fields as necessary:
- Specification Name
- Enter the specific or generic name of an existing analysis specification. If you specify a generic value, a list of valid analysis specifications is displayed.
- Option
- When
the scope of the analysis specification is a CICS® system
group, you must indicate how the CICS systems
comprising the CICS system group are to use the specification.
To do this, specify one of the following:
- FORCE
- All CICS systems in the CICS system group are to inherit the new specification.
- KEEP
- Any CICS system that inherited a specification from the CICS system group is to be explicitly assigned the old specification; all other CICS systems in the group are to be unaffected.
- NAME
- Any CICS system that inherited a specification from the CICS system group is to be explicitly assigned the new specification; all other CICS systems in the group are to be unaffected.
- NULL
- Any CICS system in the CICS system group that is not explicitly associated with a specification is to inherit the new specification; all other CICS systems in the group are to be unaffected.
Note: The Option field does not appear on this view when the scope is a CICS system (CICSSYS).
- Click Yes to update the scope to analysis specification association. Otherwise, click No to abandon the process.
Change the following information, as appropriate: If
you update the analysis specification for a CICS system
that is already active, the new specification is not immediately available.
To reset real-time analysis, you must display theMASs known to
CICSplex tabular view and do one of the following:
- If real-time analysis is not already active (as indicated by NO
in the RTA Active field):
- Click the record check box beside the MAS entry and click the Update... button.
- On the MASs known to CICSplex detailed view, change the RTA Active field to YES.
- Click Yes to turn real-time analysis on.
- If real-time analysis is active (as indicated by YES or SAM in
the RTA Active field),
- Click the record check box beside the MAS entry and click the Update... button.
- On the MASs known to CICSplex detailed view, change the RTA Active field to NO.
- Click Yes to turn real-time analysis off. The MASs known to CICSplex tabular view is displayed.
- Click the record check box beside the MAS entry and click the Update... button.
- On the MASs known to CICSplex detailed view, change the RTA Active field to YES.
- Click Yes to turn real-time analysis on.