Step 2: Defining cross-domain resources for a CMAS
Define cross-domain resources (CDRSCs) when a CMAS that is to communicate with another CMAS cannot take advantage of adjacent CDRSCs or you want to minimize the effort involved in using adjacent CDRSCs.
To establish a CDRSC definition, you must either create a new member
or access an existing member in the SYS1.VTAMLST library. In the new
or existing member, specify the following CDRSC statement for each
CMAS that you want to communicate with:
VBUILD TYPE=CDRSC
name CDRSC CDRM=cdrm
where:
- name
- The name you assigned to a CMAS in Step 1.
- cdrm
- The name of the MVS™ image previously identified as the cross-domain resource manager (CDRM).
For example, to allow the CMAS on SYSA to communicate with the
CMASs on SYSB and SYSC, you might create the member CDRCMS1 in the
SYS1.VTAMLST library, that contains the CDRSC statements:
VBUILD TYPE=CDRSC
CMS2 CDRSC CDRM=VTAMB
CMS3 CDRSC CDRM=VTAMC
where VTAMB and VTAMC are the cross-domain resource manager names that are assigned to SYSB and SYSC respectively.
You also require the same types of definitions for the CMASs on
SYSB and SYSC. That is, for the CMAS on SYSB, you might create a member
CDRCMS2, that contains the CDRSC statements:
VBUILD TYPE=CDRSC
CMS1 CDRSC CDRM=VTAMA
CMS3 CDRSC CDRM=VTAMC
Note: VTAM® is now z/OS® Communications Server.