DBCTL failure
A termination of DBCTL should not cause CICS® to terminate, it leaves CICS without DBCTL services. The DRA remains partially initialized to help reduce the restart time.
If any of the DBCTL address spaces (DBC, DBRC, or DLISAS) fails, all of these address spaces are terminated and you must restart the system using an /ERESTART command.
If you are using the IRLM as your lock manager, and it has failed as well as DBCTL, you must restart it before restarting DBCTL. See IRLM failure.
DFS628I ABNORMAL TERMINATION SCHEDULED DFS629I IMS DBC REGION ABEND
jobname 0020
DFS613I DBC RCN U113 DUE TO Sxxx Uyyyy DURING DL/I CALL IN CCTL
zzzzzzzz dddd
- xxx
- is the system abend code. This is S000 if it is a user abend.
- yyyy
- is the user abend code. This is U0000 if it is a system abend.
- zzzzzzzz
- is the job name of the abending CICS system or BMP.
- dddd
- is the DBCTL system identifier.
DFS613I DBC RCN U113 DUE TO S000 U0474 DURING DL/I CALL IN CCTL
DBDCCICS IMSA
CICS is isolated from such abends because, in DBCTL, each thread TCB has its own extended subtask ABEND exit (ESTAE).
The threads are then terminated and the DRA attempts to reconnect to DBCTL. Any requests made by the subsystem during this period result in a return code of 40, which indicates that no active communications exist with DBCTL, or a return code 28, which indicates that the specified thread does not exist. These return codes are included in messages DFHDB8104, DFHDB8109, DFHDB8111, and DFHDB8130. Guidance on interpreting them is in the DBCTL DRA return codes appendix of IMS messages and codes .
The DRA attempts to reconnect to DBCTL. After the first failing attempt, you are given the opportunity to reply to message DFS690A. You can reply either WAIT, in which case the DRA continues trying to reconnect, or CANCEL, in which case the DRA stops trying to reconnect. If you reply CANCEL, you must use the CDBC transaction to reconnect DBCTL.
If you reply WAIT, the time interval between each attempt to reconnect is as specified in the DRA startup parameter TIMER (described in Defining the IMS DRA startup parameter table).
If you reply WAIT and later want to prevent further attempts to reconnect, use the CDBC DISCONNECT transaction. (See Deciding whether to use orderly or immediate disconnection.)