Analyzing an SVC dump issued by a DSNGDxxx module

When an SVC dump is issued by a DSNGDxxx module, a programming error was encountered while a DBD was being built or modified. In this case, there is nothing that can be done to analyze the structure of the DBD because the structure is not completed.

About this task

After you complete the following steps, contact IBM® Support for assistance.

Procedure

To analyze an SVC dump that is issued by a DSNGDxxx module:

  1. Print the dump that was issued.
  2. Make a note of the SQL operations that were being performed before the dump was issued. If you cannot determine what SQL operations were going on, review the description of the abend code. This information might help IBM Support understand and resolve the problem.
  3. To prevent more DDL activity from causing further damage, issue a -START DATABASE command for read-only (RO) access for the catalog database, DSNDB06:

    Begin general-use programming interface information.

    -START DATABASE (DSNDB06) ACCESS (RO)

    End general-use programming interface information.