Detail line hierarchy

An unexpanded I07 report shows a line for each IMS™ DL/I call in which CPU usage was observed. The name field shows a sequence number assigned to each unique DL/I call. You can expand each line to reveal additional hierarchical levels of detail. The hierarchy is illustrated here:

Level 1 DL/I call identification
	Level 2 Category
		Level 3 Load module
				Level 4 CSECT
	Level 2 SVC total
		Level 3 SVCnnn
				Level 4 Load module
						Level 5 CSECT