Detail window
You can enter “++” (or the Enter key) on any line to display a pop-up window containing additional information. A sample detail window for this report is shown here:
File View Navigate Help
+----------------------------------------------------------------------------+
| |
| +--------------- The following report line was selected ---------------+ |
| | 18802338 + LPFRAYV4 31 P8 50.44 OOOOOOOOOOOOOOOOOOOOOOOOO | |
| +----------------------------------------------------------------------+ |
| |
| Calculation Details |
| CPU measurements 4,056 |
| PSW address 18802338 |
| Total CPU measurements 8,040 |
| Percent in category 50.44% |
| |
| PSW Information |
| PSW Address 18802338 |
| Module Name LPFRAYV4 |
| CSECT Name LPFRAYV4 |
| Module+Offset LPFRAYV4+1748 |
| CSECT+Offset LPFRAYV4+1748 |
| Addressing Mode (AMODE) 31 bit |
| Address Space Control Primary Space |
| Problem/Supervisor Mode Problem Mode |
| |
| Machine Instructions |
| LPFRAYV4+1744 47F0 B0C2 BC 15,194(,R11) |
| LPFRAYV4+1748 FA20 A830 9075 AP 2096(3,R10),117(1,R9) <- PSW add |
| |
+----------------------------------------------------------------------------+