IBM(R) InfoSphere(TM) Master Data Management Server for Product Information Management, Version 9.0.0, Test Fix 9 is now available. This release notes document addresses system requirements, installation, and known problems for this test fix.
Contents
Description of this test fix
InfoSphere MDM Server for PIM provides a highly scalable, enterprise Product Information Management (PIM) solution. InfoSphere MDM Server for PIM is the middleware that establishes a single, integrated, consistent view of products and services information inside and outside of an enterprise.
Caution:
It is strongly recommended that you apply the test fix only to a test
system. Test fixes do not undergo official IBM testing.
This test fix addresses the following enhancements and fixes:
The following fixes were included in this test fix as a result of an authorized program analysis report (APAR). You can search for and view existing APARs here: InfoSphere MDM Server for PIM Support site. You can also review the associated PMR (if one is identified) for the fix, with the Electronic IBM Service Request tool Web site: Service Requests.
Note: This APAR fix is an optional behavior change, and will only be enabled by adding the new nonindexed_search_like_indexed parameter to the common.properties file and setting it to true. See the List of configuration file changes section below for more information.
The following fixes were included in this interim fix as a result of enhancement that was discovered by the development team. If you want to learn more about one of these fixes, you can use the internal defect number for reference when speaking to someone from IBM Software Support:
Note: This CR fix is an optional behavior change, and will only be enabled by adding the new save_as_draft_enabled parameter to the common.properties file and setting it to true. See the List of configuration file changes section below for more information.
Note: Few fixes done in InfoSphere MDM Server for PIM, version 6.0.0, Fix Pack 8 have not been fore-ported to this test fix release. The issues reported in this previous fix pack may occur in this test fix release.
Note: This test fix contains numerous fixes for UI and performance defects and it is recommended that you download and apply this test fix.
Limitations:
Work around: Admin can use the classic UI to release items reserved by other users.
You can review the release notes of previous maintenance releases for
InfoSphere MDM Server for PIM, version 9.0.0, to see what
enhancements or product fixes were included previously:
Fix Release | Release Notes(R) | Release Date |
---|---|---|
interim fix 3 | Release Notes for interim fix 3 | 10/01/2010 |
fix pack 4 | Release Notes for fix pack 4 | 09/21/2010 |
interim fix 2 | Release Notes for interim fix 2 | 09/02/2010 |
fix pack 3 | Release Notes for fix pack 3 | 08/09/2010 |
interim fix 1 | Release Notes for interim fix 1 | 07/20/2010 |
fix pack 2 | Release Notes for fix pack 2 | 07/06/2010 |
fix pack 1 | Release Notes for fix pack 1 | 05/17/2010 |
System requirements
For information about hardware and software compatibility, see the detailed system requirements document at: http://www.ibm.com/software/data/infosphere/mdm_server_pim/requirements.html.
Installing test fix 9
Before you install this test fix, you must have installed InfoSphere MDM Server for PIM, Version 9.0.0. In particular, make sure that you have applied all configuration changes. For example, any schema changes and common.properties updates as documented in the Requirements section of those release notes.
Important: Before starting the installation process, you must clean your browser cache. Additionally, all users must clean their browser cache before using the user interface for the first time after a fix pack, interim fix, or test fix has been applied. Frequently, JavaScript files that the user interface depends on are updated and installed with each release. These JavaScript files are cached by the browser when the user interface loads. So, in order to avoid incompatibilities and issues in using the user interface, you must clean your browser cache such that the latest JavaScript files are loaded and used by the user interface.
Remember: This maintenance release is a cumulative patch. You can apply this patch from any previous maintenance release level of Version 9.0.0.
Important:
The steps for installing this test fix include:
Step 1. Preparing to install the test fix
Before you install the test fix, make sure to complete these steps:
$TOP/bin/go/svc_control.sh --action=stop --svc_name=scheduler
$TOP/bin/go/svc_control.sh --action=short_status--svc_name=workflowengine
If no events are running, shut down the workflow engine manually by running the following shell script:
$TOP/bin/go/svc_control.sh --action=stop --svc_name=workflowengine
$TOP/bin/go/abort_local.sh
Running the abort_local.sh shell script does not affect any of the other JVM services.
$TOP/bin/gdsmsg.sh abort
The installation will overwrite your current files with updated versions from the test fix. If any issues occur when installing the test fix, you can use this backup copy to rollback the installation.
Step 2. Installing the test fix
To install this test fix, you must perform the following steps:
For example: WPC_HOME/tarFileTemp
cd $TOP chmod -R 755 $TOP
For example, when using the GNU .tar utility, the following command extracts and unzips the .tar file by using an absolute path:
tar zxvf $TOP/9.0.0-WS-MDMPIM-TF009-01_update_from_9000-45.tgz
Important: The InfoSphere MDM Server for PIM files were packed using the GNU tar utility. For best results, use the GNU tar utility to unpack the files.
Remember: If you are migrating from InfoSphere MDM Server for PIM, Version 9.0.0, Fix Pack 3, Interim Fix 2, Fix Pack 4, or Interim Fix 3, you can skip this step and continue with the Step 2.3.
Note: For some configuration files, if you have customized the content of a configuration file and you choose to overwrite the file when running configureEnv.sh, you need to manually restore the values in the file that you have customized using the backup copy that is created. The file name of the backup copy is the name of the corresponding configuration file with the extension ".bak" appended to the end of the name. The exception to this overwriting behavior is common.properties.
Please also note that by running configureEnv.sh two or more times, you can lose the original customized configuration files. This is because the backup copy of a configuration file gets replaced in place (same file name is used for a given configuration file every time configureEnv.sh is run).
The application server shell script, install_war.sh, installs InfoSphere MDM Server for PIM into the WebSphere application server.
Ensure that the default WebSphere application server (server1) is installed and running. You also need to verify that you can log into the server. For more information about the default WebSphere application server, see the administration information in the WebSphere Application Server information center at: http://publib.boulder.ibm.com/infocenter/wasinfo/v7r0/index.jsp.
install_war.sh [ --wsadminUsername=<WAS admin user name> --wsadminPwd=<password for WAS admin user>]
install_war.sh will install the WAR file for each app server defined in the [services] section in env_settings.ini. When WebSphere Application Server security is enabled, add the wsadminUsername and wsadminPwd arguments to the install_war.sh command.
Note: Starting with V9.0.0 fix pack 3, when WebSphere Application
Server security is enabled, the following arguments are no longer required in
the $TOP/bin/start_local.sh, $TOP/bin/start_rmi_appsrv.sh,
$TOP/bin/stop_local.sh, and $TOP/bin/rmi_status.sh
commands:
--wsadminUsername=<WAS admin user name> --wsadminPwd=<password for WAS admin user>
install_gds_war.sh
Step 3. Enabling the Global Data Synchronization feature of InfoSphere MDM Server for PIM (Optional)
Complete this step only if you plan to use the Global Data Synchronization feature of InfoSphere MDM Server for PIM; otherwise, proceed to Step 4.
Note: If you want to use the Global Data Synchronization feature on InfoSphere MDM Server for PIM version 9.0.0, you must apply interim fix 3 or later releases to configure the environment for enabling GDS. Since interim fix 3 release of InfoSphere MDM Server for PIM, version 9.0.0, Global Data Synchronization conforms to Business Message Standard (BMS) 2.7 specifications and previous versions are conformed to BMS 2.3 specifications.
Important: The interim fix 3 or later releases does not provide any migration support to upgrade your Global Data Synchronization data model and data from BMS 2.3 to BMS 2.7 specifications. Therefore, you must create a new company, load the Global Data Synchronization data model provided in InfoSphere MDM Server for PIM version 9.0.0, Interim Fix 3, and then add the data for this data model into the new company.
To enable the Global Data Synchronization feature of InfoSphere MDM Server for PIM, Version 9.0.0, you must perform the following steps:
Step 4. Updating the configuration files
To successfully use the fixes and enhancements in this maintenance release you must ensure to modify InfoSphere MDM Server for PIM configuration files.
InfoSphere MDM Server for PIM uses the following configuration files:
The following table includes all InfoSphere MDM Server for PIM fix versions, along with their corresponding configuration file changes that you must apply. Depending on the InfoSphere MDM Server for PIM fix version you are migrating from, use this table to determine which configuration file changes you must apply, then view the list of configuration file changes that follow for the specific details.
Remember: If you migrate from version V9.0.0, Interim Fix 3, you must
apply the configuration file changes defined in 1 of the list of configuration
file changes.
Your fix version | List number of the configuration file change |
---|---|
9.0.0 interim fix 3 | 1 |
List of configuration file changes
# Parameter to control the behavior of search for non-indexed multi-occurring attributes. # If false, then the search results for non-indexed multi-occurring attributes # can be different from the behavior for indexed multi-occurring attributes in the following scenarios: # - "IS EMPTY" predicate: A non-indexed multi-occurring attribute will only match the "IS EMPTY" predicate if it has # zero occurrences, but an indexed multi-occurring attribute will match it if either # it has zero occurrences, or the attribute value is empty in every occurrence. # - "NOT IS EMPTY" predicate: for both non-indexed and indexed multi-occurring attributes: it matches "NOT IS EMPTY" # if and only if it doesn't match "IS EMPTY". # If true, then search results for non-indexed multi-occurring attributes # will be the same as those for indexed multi-occurring attributes. # Default is false, for backward compatibility. nonindexed_search_like_indexed=false # Controls whether "save-as-draft" functionality is enabled # When save-as-draft is enabled, saves in collaboration areas always save even if there are invalid values # Entries cannot move to the next step if there are validation errors. # Some customers prefer that invalid entries never save. Other situations have large numbers of required attributes # Thus, it makes sense to save frequently even before all required values are entered. # By default save-as-draft is enabled save_as_draft_enabled=true
The "enable_memorymonitor" default value is been set to "false" in common.properties.default , so all new installation with get that default setup.
Section of common.properties in InfoSphere MDM Server for PIM, Version 9.0.0, test fix 8:
# Enable memory monitoring of session usage enable_memorymonitor=false
The default logging level of "info" for com.ibm.ccd.concurrency.* packages is been set to eliminate the excessive logging of ReleaseLocksForThread in default.log.
<category name="com.ibm.ccd.concurrency" additivity="false"> <priority value="info" /> <appender-ref ref="DEFAULT" /> </category>
Step 5. Modifying the database schema
Several changes are made to the database schema in the test fix release of InfoSphere MDM Server for PIM version 9.0.0; therefore, you must run a migration shell script to migrate to the database schema of InfoSphere MDM Server for PIM, version 9.0.0, Test Fix 8.
Note: The migrations provided are for general InfoSphere MDM Server for PIM data structures and data, and do not provide the GDS data model modifications for compliance to the BMS 2.7 specifications.
Remember: If you are migrating from InfoSphere MDM Server for PIM, Version 9.0.0, Test Fix 7, or Test Fix 8, you are not required to run the migration shell script. You can skip this step and continue with the next step, Step 6. Verifying the installation.
To migrate your database schema:
migrateToInstalledFP.sh --fromversion=BASE|FP1|IF1|FP2|FP3|IF2|FP4
BASE, FP1, IF1, FP2, FP3, IF2, FP4 correspond to the fix pack you are
migrating from. For example, you must use BASE if you have never
installed a fix pack over the InfoSphere MDM Server for PIM version
6.0.0.
If you are migrating from V9.0.0 Interim Fix 3, you must use
FP4.
If you are migrating from a Test Fix version use the table below to
determine which Fix Pack the Test Fix was built on.
Test Fix Version | Version |
---|---|
TF1 | V9.0.0 GA |
TF2 | V9.0.0 GA |
TF3 | V9.0.0 - FP001 |
TF4 | V9.0.0 - FP001 |
TF5 | V9.0.0 - FP001 |
TF6 | V9.0.0 - FP002 |
TF7 | V9.0.0 - IF004 |
TF8 | V9.0.0 - IF004 |
$TOP/bin/migration/migrateToInstalledFP.sh --fromversion=BASE
This optimizer script uses the catalog tables from a database to obtain information about the database, including the amount of data within the database and other characteristics. The optimizer script then uses this information to determine how to access the data. If your database statistics are not available, the optimizer might choose an inefficient access plan based on the default statistics, which is inaccurate.
You should use the analyze_schema.sh shell script to collect your current statistics from within the tables and indexes, especially if significant update activity has occurred since the last time you ran the analyze_schema.sh shell script.
To run the analyze_schema.sh shell script in DB2, refer to the InfoSphere MDM Server for PIM technote: Analyzing WebSphere Product Center schema and collecting statistics in DB2 located at: http://www-1.ibm.com/support/docview.wss?uid=swg21205939.
Important: Run the analyze_schema.sh shell script on your InfoSphere MDM Server for PIM databases at least once a week or when there has been at least a twenty percent increase or change in data on the database.
Tip: Oracle version 10g and 11g has automatic statistics gathering job enabled by default.
All messages, such as the status of individual migration components and the overall migration summary, are displayed in the console.
After running the migration script, messages are displayed in the console that indicate whether the migration succeeded or failed. This message is displayed if the migration succeeded:
-------------------------------------- Summary of the migration: -------------------------------------- Migration to InfoSphere MDM Server for PIM 9.0.0 successful.
This message is displayed if the migration failed:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Migration Failed : xxxx !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Please see the file for further details : /home/pimuser/mdmpim900/logs/errfile.log
This message is displayed if the migration of specific modules failed:
-------------------------------------- Summary of the migration: -------------------------------------- Migration of the following modules failed : <module names>
Review the error.log file for additional messages. For SQL errors, find the detailed error message from the SQL error code, correct the error, and run the migration script again. Contact IBM Software Support if the problem persists after correcting the errors.
Migration script can fail with the following reasons:
----------------------------------------------------------- Summary of the migration ----------------------------------------------------------- Migration of the following modules failed: modify_sca_table $TOP/logs/errfile.log will have the following content: PK_CHECK ------------- ERROR: SCA_PK 1 record(s) selected.
This is because there are some duplicate records in the tctg_sca_selected_category table. Duplicate rows should be removed for migration script to complete successfully.
To remove duplicates, follow the steps mentioned below from $TOP directory of InfoSphere MDM Server for PIM server. Replace db_user, db_password, and db_name with the appropriate values from $TOP/bin/conf/env_settings.ini file. After the successful completion rerun the migration script.
If the back-end database is DB2:
db2 connect to db_name user db_user using db_password
db2 "create table sca1 like tctg_sca_selected_category" db2 "insert into sca1 select distinct sca_company_id, sca_selection_id, sca_catalog_id, sca_cat_tree_id, sca_category_id from sca" db2 "delete from sca" db2 "insert into sca select * from sca1"
db2 "drop table sca1"
If the back-end database is Oracle:
sqlplus db_user/db_password@db_name
create table sca1 as select distinct sca_company_id, sca_selection_id, sca_catalog_id, sca_cat_tree_id, sca_category_id from sca; delete from sca; insert into sca select * from sca1;
drop table sca1; quit;
----------------------------------------------------------- Summary of the migration ----------------------------------------------------------- Migration of the following modules failed: data_maintenance_reports
$TOP/logs/errfile.log will have the following content:
net.sf.ehcache.distribution.MulticastKeepaliveHeartbeatReceiver$MulticastReceiverThreadrun SEVERE: Multicast receiver thread caught throwable. Cause was null. Continuing...
This is because there is an issue with the cache configuration parameters, but migration script continued and completed successfully. Check your cache configuration parameters. No need to re-run the migration script.
For catalogs in a company:
For hierarchies in a company:
For items in a company:
In the example command provided below, the Index Regeneration Capability utility runs the items in the CSV file, $TOP/item-list.csv in the company named test_Co, using the utf8 encoding.
$TOP/bin/indexRegenerator.sh --items=$TOP/item-list.csv --company=test_Co --encoding=utf8
Parameters that contain spaces and special characters must be enclosed between quote characters (") and special characters alone, should be escaped with a backslash (\).
If you specify more than one file, the file number is placed before the file extension. Like items.csv becomes items-1.csv, items-2.csv, etc.
Restriction: Catalog and hierarchy arguments cannot be combined. For example, --catalog and --hierarchy cannot be used together, nor can --catalog and --categories. When arguments --catalog and --items are used together, only PK files are generated and no index regeneration is performed.
Step 6. Verifying the installation
Every time that you install a test fix, verify that the installation was successful. To verify the installation of this test fix, complete these steps:
The shell script, start_local.sh, located in the $TOP/bin/go/ directory, starts all the services that you need to run InfoSphere MDM Server for PIM.
The svc_control.sh supports starting multiple services from the same command:
svc_control.sh --action=start --svc_name=<service name>[--svc_name=<service name>]
svc_control.sh --action=start --svc_name=admin --svc_name=scheduler
gdsmsg.sh start
This process should only take approximately 30-40 seconds, depending on the speed of your CPU processor.
Note: InfoSphere MDM Server for PIM running on WAS platform preserves Web services already registered with PIM, so re-deployment of Web services is not necessary. But InfoSphere MDM Server for PIM running on Weblogic platform requires re-deployment of Web services at startup time. This re-deployment is accomplished using command options of "redeploy" and "waitforappsvr", as shown in the follow syntax:
start_local.sh --redeploy --waitforappsvr=<number of seconds>
or
svc_control.sh --action=start --svc_name=admin --svc_name=scheduler [ --svc_name=appsvr --redeploy [--waitforappsvr=<number of seconds>] ]
- where the <number of seconds> is the number of seconds (positive integer) that the deployment command will wait for the appsvr services to become ready to initiate the re-deployment of Web services. The default value of this option is 5 seconds.
The waitforappsvr option must be used with the redeploy option. When the waitforappsvr option is omitted in a command with the "redeploy" option, the default value of waitforappsvr takes effect.
Users are advised to supply value slightly greater than the required startup time of appsvr service, which can be monitored using the rm_status.sh command as shown in step 6.2 below. Too low a value for the waitforappsvr option can result in errors with stack dump on screen or log files.
The --svc_name=appsvr option in the svc_control.sh command must be accompanied by the redeploy and optionally the waitforappsvr command options.
Run the $TOP/bin/go/rmi_status.sh script and verify that the following services have started correctly:
Run the following script to verify that the GDS messaging services have started correctly:
$TOP/bin>./get_ccd_version.sh 9.0.0-TF009#1
Known problems
If the spec ordering of an item in the tabbed view of workflow is not in the expected order, refresh the collaboration area to view them in the expected order. Fix for this issue will be provided in a subsequent maintenance release.
Known problems are documented in the form of individual technotes in the Support knowledge base at InfoSphere MDM Server for PIM Support Site. As problems are discovered and resolved, the IBM Support team updates the knowledge base. By searching the knowledge base, you can quickly find workarounds or solutions to problems.
The following link launches a customized query of the live Support knowledge base for all published technotes for InfoSphere MDM Server for PIM: View all known problems for InfoSphere MDM Server for PIM
You can search for keywords within this complete list of technotes.