Fix (APAR): PH24552 Status: Fix Release: 9.0.5.3 Operating System: Windows Supersedes Fixes: CMVC Defect: xxxxxx Byte size of APAR: 348174 Date: 2020-05-19 Abstract: PI89036 causes native_stdout to fill up with repeating debug timestamps Description/symptom of problem: PH24552 resolves the following problem: ERROR DESCRIPTION: WAS ND 9.0.5.3 and 8.5.5.17 on Windows After updating to WAS 9.0.5.3 or 8.5.5.17, PI89036 results in continual debug timestamps generated to native_stdout: ProcessCPU Java_com_ibm_ws_xd_pmi_processcpu_ProcessCPU_nativeEnableDebugMode ENTER ProcessCPU Java_com_ibm_ws_xd_pmi_processcpu_ProcessCPU_nativeEnableDebugMode EXIT followed by a series of timestamps every 15 seconds: [04/16/20 14:39:06] [04/16/20 14:39:06] ... [04/16/20 14:39:21] [04/16/20 14:39:21] ... LOCAL FIX: none PROBLEM SUMMARY: Over a period of time, native_stdout.log on Windows fills up with repeating debug timestamps when PMI is invoked to collect CPU statistics. This was caused due to a fix for PI89036 which failed to check for debug mode prior to writing out some timestamps in the log file. USERS AFFECTED: All users of IBM WebSphere Application Server PROBLEM DESCRIPTION: native_stdout.log on Windows fills up with repeating debug timestamps when PMI is invoked to collect CPU statistics RECOMMENDATION: None PROBLEM CONCLUSION: The code was updated to check for debug mode prior to writing ou timestamps to native_stdout.log. The fix for this APAR is targeted for inclusion in fix packs 8.5.5.18 and 9.0.5.4. For more information, see 'Recommended Updates for WebSphere Application Server': http://www.ibm.com/support/docview.wss?uid=swg27004980 Directions to apply fix: Install Fix to all WebSphere installations unless special instructions are included below. Special Instructions: None NOTE: The user must: * Logged in with the same authority level when unpacking a fix, fix pack or refresh pack. * Be at V1.8.5 or newer of the Installation Manager. Certain iFixes may require a newer version of the Installation Manager and the Installation Manager will inform you during the installation process if a newer version is required. The IBM Information Center can provide details, if needed, on the use of the Installation Manager to apply the iFixes. http://www.ibm.com/support/knowledgecenter/SSDV2W_1.8.5/com.ibm.cic.agent.ui.doc/helpindex_imic.html. Shutdown WebSphere Application Server before applying the iFixes. Restart WebSphere Application Server after applying the iFixes. Directions to remove fix: The IBM Information Center can provide details, if needed, on the use of the Installation Manager to remove the iFixes. http://www.ibm.com/support/knowledgecenter/SSDV2W_1.8.5/com.ibm.cic.agent.ui.doc/helpindex_imic.html. Shutdown WebSphere Application Server before removing the iFixes. Restart WebSphere Application Server after removing the iFixes. Directions to re-apply fix: 1) Shutdown WebSphere Application Server. 2) Follow the Fix instructions to apply the fix. 3) Restart WebSphere Application Server. Additional Information: After applying the fix, reboot the Windows machine at OS level.