The patch notes contain
the following sections:
COMPLETED CHANGE REQUESTS |
|
|
|
35774 | 4.2.2.5 |
FlowManager was hanging when a find operation was performed against 1000's of records. The 'event number' column was not resizeable in the resulting tabular view. This CR fixes both the problems. |
43925 |
4.2.2.5 |
The MQ HOST_NAME was not allowed to be blank. This fix will allow the hostname
to be set to a blank value. |
44314 |
4.2.2.5 |
When BO's were saved from LogViewer the closing tag, '>' was missing in the created file. This problem is fixed now. The created BO's can be opened properly. |
44394 |
4.2.2.5 |
In System Manager right click on a collaboration and expose it as a webservice.
When this webservice is imported into WSAD5.1, it gives an error because
the System Manager missed a couple of tags in the generated xml file correponding
to the collaboration. This fix solves that problem. |
44539 |
4.2.2.5 | |
59991 |
4.2.2.5 |
While editing static relationship in Relationship Manager, the original
value disappears when we switch to a different row and come back. |
60249 | 4.2.2.5 |
The Connector Configurator could not load App properties template file
when the user uses it to open an existing connector file. This will result
in potential problems such as Connector Configurator not knowing any useful
info (for example valid values, and length limitation for a String type
property) which are configured in App properties template file. The fix
will enable Connector Configurator to load its corresponding App properties
template file while opening an existing connector file. |
60365 |
4.2.2.5 |
Process designer, while saving Collaboration templates was generating 2
TransitionLinks instead of one. This fix will solve that problem |
44832 |
4.2.2.5 |
In Connector Configurator when a user adds a value and/or a range for a Connector-Specific property, they will feel confused about how to operate two Radio Buttons in "Property Value" Dialog. This fix gets rid of this confusion. This fix removes those two Radio Buttons and adds a CheckBox Button for "Range". |
44865 |
4.2.2.5 |
The deletion of Scheduler component was not happening properly. The System
manager continued to show deleted scheduler components. This fix solves
that problem. |
44866 |
4.2.2.5 |
The changes made to Relationships using Relationship Designer was not reflected
when seen through System Manager. If a relation is changed from Static
to Dynamic, it'll be shown under correct folder now after the fix. |
44907 |
4.2.2.5 |
In Connector Configurator when a user wants to set a range for a Connector-Specific
property whose type is Time, the two border values of this range should
comply with the format of time ie.. hh:mm and should not be random values.
This fix implements that validation. |
44908 |
4.2.2.5 |
In Connector Configurator the Connector-specific property whose type is
Time should validate the Range of values. Previously even after setting
a specific Range, the property was allowing entry of values outside of
the range. Now this fix validates the values to fall within the set Range |
44909 |
4.2.2.5 |
In Connector Configurator the Connector-Specific property whose type is int, should allow only values set between the range. This fix validates the range and does not allow for entry of values outside the configured range. |
58757 | 4.2.2.5 |
Recurring Events should not be shown as expired events. This fix solves
that problem |
44384 |
4.2.2.5 |
In system manager, when you right click a user project and choose to deploy
to WAS, and you choose "Export to a Directory", the moment you start typing "c:", a error message pops up saying: "c: already exists, do you want to overwrite it?". That error handling needs to be moved to only run after the user finishes typing the whole path and clicks FINISH. This fix solves that problem |
58623 |
4.2.2.5 |
When a subdirectory is created in the directory where all the BOs
of a component library are stored (usually %CROSSWORLDS%\Tools\WSWB203\Workspace\<your_ICL>\BusinessObjects,
and you run "refresh view" in SystemManager and start BO Designer
afterwards out of SystemManager, it will crash with a C++ error. This fix
solves that problem |
58943 |
4.2.2.5 |
If System Manager disconnects from an InterchangeServer and tries to reconnect
after PersistentNameServer and ICS have been restarted, System Manager
gets an exception - org.omg.CORBA.OBJECT_NOT_EXIST:BAD_SERVER_ID: |
58626 |
4.2.2.5 |
If a subdirectory was created under %Crossworlds%\Tools\WSWB203\Workspace\<ICL>\BusinessObjects
folder, the process designer did not allow choosing of BO in collaboration
template. This fix will solve that problem. |
59596 |
4.2.2.5 |
In System Manager, System view does not refresh itself when the ICS is
stopped\shutdown. The System View reflects the status of ICS properly only
after the System Manager is closed and reopened. This fix solves that problem. |
44912 |
4.2.2.5 |
For those Connector-Specific
Properties whose default value(s) are set to be editable, the previous
Connector Configurator can not save any changed new values of these
properties successfully. This fix will resolve that error. |
60746 |
4.2.2.5 |
The current flowmanager does not have confirm delete as a default setting.
This fix makes it default. |
45082 |
4.2.2.5 |
This fix will force the
Connector Configurator to adopt the time format of 24-hour. This will
avoid those potential errors caused by different locale's time format
configuration |
45078 |
4.2.2.5 |
When configuring a template the
user should first add a property and then configure the added
property's type. But if the user directly selects type to be Boolean
without adding any property into a empty template, Connector
Configurator will crash and be closed by Windows OS forcibly. This fix
will resolve this error. |
44736 |
4.2.2.5 |
In Map Designer, when a Business Object is saved from the Test tab, the
data is truncated. The saved Business object contains only the starting
character of the fields intended to be saved. This fix solves that problem. |
44868 | 4.2.2.5 | The Flow Manager does not delete server and user that were deleted through the Option Window - The dialog that comes up when option button is clicked. Now this fix solves that problem. |
44892 | 4.2.2.5 | Flow Manager could not sort entries based on the "event status" column. This fix solves that problem. |
61100 | 4.2.2.5 | In system Manager while importing components from ICS into a project the progress bar was not working. This fix solves that problem. |
To perform an upgrade to this version of the WBI Toolset, please follow instructions in the correct order as follows:
Below are a list of files
that need to be replaced in this patch:
For
WICS Version
|
Platform
[Windows]
|
Add / Replace / Remove |
File
(Starting from ~/IBM/WebSphereICS/
|
4.2.2.5 | Windows 2000/XP | Replace | bin/BusObjDesigner.exe |
4.2.2.5 | Windows 2000/XP | Replace | bin/ConnDesigner.exe |
4.2.2.5 | Windows 2000/XP | Replace | bin/ProcessDesigner.exe |
4.2.2.5 | Windows 2000/XP | Replace | bin/MapDesigner.exe |
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps.xml |
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps_chs_chn.xml |
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps_cht_twn.xml |
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps_deu_deu.xml |
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps_esn_esp.xml |
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps_fra_fra.xml |
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps_ita_ita.xml |
4.2.2.5
|
Windows 2000/XP | Replace |
bin/Data/Std/StdConnProps_jpn_jpn.xml
|
4.2.2.5
|
Windows 2000/XP | Replace |
bin/Data/Std/StdConnProps_kor_kor.xml
|
4.2.2.5 | Windows 2000/XP | Replace | bin/Data/Std/StdConnProps_ptb_bra.xml |
4.2.2.5 | Windows 2000/XP | Replace | bin/ActivityEditor.dll |
4.2.2.5 | Windows 2000/XP | Replace | bin/CxCommon2.dll |
4.2.2.5 | Windows 2000/XP | Replace | bin/SMInterface.dll |
4.2.2.5 | Windows 2000/XP | Replace | bin/Utils.dll |
4.2.2.5 | Windows 2000/XP | Add | bin/CC001224W040202.sys |
4.2.2.5 | Windows 2000/XP | Replace | lib/datamanager.jar |
4.2.2.5 | Windows 2000/XP | Replace | lib/flowmanager.jar |
4.2.2.5 | Windows 2000/XP | Replace | lib/ConfigWizard.jar |
4.2.2.5 | Windows 2000/XP | Replace | lib/cwsnmpagent.jar |
4.2.2.5 | Windows 2000/XP | Replace | lib/vtc.jar |
4.2.2.5 | Windows 2000/XP | Replace | lib/relmgr.jar |
4.2.2.5 | Windows 2000/XP | Replace | lib/CrossWorlds.jar |
4.2.2.5 | Windows 2000/XP | Replace | WBSM/CWDashboard.war |
4.2.2.5 | Windows 2000/XP | Replace | WBSM/WBSMMigrate.jar |
4.2.2.5 | Windows 2000/XP | Replace | plugins/com.ibm.btools.csm |
4.2.2.5
|
Windows 2000/XP | Replace |
plugins/com.ibm.btools.itools.codeGen
|
4.2.2.5
|
Windows 2000/XP | Replace |
plugins/com.ibm.btools.itools.datamanager
|
4.2.2.5 | Windows 2000/XP | Replace | plugins/com.ibm.btools.itools.testingenv |
4.2.2.5 | Windows 2000/XP | Replace | plugins/com.ibm.btools.itools.collaboration.debugger |
4.2.2.5 | Windows 2000/XP | Replace | plugins/com.ibm.btools.itools.flowtrace |
4.2.2.5 | Windows 2000/XP | Replace | plugins/com.ibm.btools.itools.wsdlgen |
4.2.2.5 | Windows 2000/XP | Replace | \bin\chs_chn\ConnDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\cht_twn\ConnDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\kor_kor\ConnDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\esp_esn\ConnDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\fra_fra\ConnDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\ptb_bra\ConnDesignerRes.dll |
4.2.2.5
|
Windows 2000/XP | Replace | \bin\deu_deu\ConnDesignerRes.dll |
4.2.2.5
|
Windows 2000/XP | Replace | \bin\jpn_jpn\ConnDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\ita_ita\ConnDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\chs_chn\ProcessDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\cht_twn\ProcessDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\kor_kor\ProcessDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\esp_esn\ProcessDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\fra_fra\ProcessDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\ptb_bra\ProcessDesignerRes.dll |
4.2.2.5
|
Windows 2000/XP | Replace | \bin\deu_deu\ProcessDesignerRes.dll |
4.2.2.5
|
Windows 2000/XP | Replace | \bin\jpn_jpn\ProcessDesignerRes.dll |
4.2.2.5 | Windows 2000/XP | Replace | \bin\ita_ita\ProcessDesignerRes.dll |
© 2004 IBM Corporation. Proprietary and Confidential. All Rights Reserved.