Fix Pack Notes for
WebSphere Business Integration (WBI) Toolset version 4.2.2.2

The patch notes contain the following sections: 
 
COMPLETED CHANGE REQUESTS

UPGRADE INSTRUCTIONS

ADDITIONAL DISCUSSION

UNINSTALL INSTRUCTIONS

COMPLETED CHANGE REQUESTS

This patch contains fixes for the following CRs based on customer reported and internally discovered issues.
 
CR Number
As of Version
Problem
33714(a.k.a 33743, 33486, 34105, 34341)
4.2.2.2
Business Object Designer: 
When saving a BO with BO Designer the changes to the BO were not immediately replicated in the System Manager. In this fixpack this defect is fixed.
32796
4.2.2.2
System Manager: 
When Flow Monitoring is enabled, the ICS uses a queue to store flow information before it is written out to the database.  The queue has a default depth (size) of 500 flows.  This number is now configurable by using the System Manager.  To configure it, connect to the ICS with the System Manager, right click on the server icon and choose Edit Configuration.  In the Edit Configuration view, choose Misc.  In the Flow Monitoring section there is a text field labeled "Max flow queue depth".  It can take values from 1 to 2147483647.  If the check box "Max Value" is checked, then the value will be set to the maximum possible value of 2147483647.
32618
4.2.2.2
Connector Designer:
Using "Save To File" to save a cfg file may incorrectly specify that the file is read only and will not be saved.
32541
4.2.2.2
Connector Designer:
Clicking on the Property column header on the Properties tab for sorting purposes causes the Connector Designer to abnormally terminate.
31399
4.2.2.2
Flow Manager:
In Flow manager bracket number in search results does not match.
Fixed search results has match bracket number.
29937
4.2.2.2
Flow Manager: 
The search in Flow Manager fails after selection of 'any' from column Event and selection of 'any' from column Verb.  If one used a locale different from US the list of column values in Event Attributes Table in Flow Manager has "any" together with local translation of "any" ("Beliebig" in German case).  It causes insertion of new row if one selects "any" and the search fail.
Fixed version has only local translation of "any" in Event Attributes Table in Flow manager and does not cause the search fail.
29691
4.2.2.2
System Manager: 
Scheduled Events panel text is cut off in Korean.
Fixed Scheduled Events panel layout by increasing width of the left Panel.
28355
4.2.2.2
Flow Manager: 
In Flow Manager, in save event popup dialog, clicking on buttons does nothing when “file saved dialog” is opened.
Fixed “save event dialog” disappear when “file save dialog” popup 
28354
4.2.2.2
Flow Manager: 
In Flow Manager ”save event dialog” shows Open button. Fixed ”save event dialog” shows Save button.
25216
4.2.2.2
Flow Manager: 
Column values in the drop down lists for values in Event Attributes Table in Flow Manager are not sorted.
Fixed Event Attributes Table has column values sorted in drop down lists.
32199
4.2.2.1
Connector Designer: 
After applying this patch, a new standard property, EnableOidForFlowMonitoring, will be added for ICS brokers. 
The property is a Boolean with a default of false.  If the property is set to true, the ADK will mark the incoming ObjectEventID as a foreign key for Flow Monitoring.
32097
4.2.2.1
System Monitor: 
System Monitor didn't show the failed events for collaborations in system overview window. 
With this fix system overview displays failed events for collaborations correctly.
31900
4.2.2.1
Process Designer: 
Business Object definitions were missing if the template definition window was not open first.  This problem caused empty business object defintions in the business object probe property, and in the correlation property of service call nodes. 
The problem is fixed so that business object definitions are correctly displayed in the respective properties without opening the template definition window first.
31824
4.2.2.1
Connector Designer: 
For WebSphere Message Brokers, if the Message Set ID is null, the supported business object was not saved in the configuration file. 
After applying this patch, the supported business object will be saved in the configuration file whether or not the Message Set ID is null.
30962
4.2.2.1
System Manager: 
The WMQI 5.0 deployment wizard in System Manager 2.4 did not print the "SchemaLoc" property in the options file used by the WMQI 2.1 schema importer. As a result, the import was incomplete. The fix in this patch ensures "SchemaLoc" property is printed.
26726
4.2.2.1
Connector Designer: 
If an already available connector configuration was changed via Connector Configurator and saved as a new connector, the properties CW:NAME in CW:ConfigurationInfo and in CW:header in the .cfg file were not being updated.  After applying this patch, these properties will be updated as the file is being saved.
25804
4.2.2.1
Connector Designer: 
If a configuration file was being saved to the same name as a current read-only file, the save message specified the save as successful. After applying this patch, an error message will indicate that the file is read-only and that it will not be saved. To remedy the situation, save to another file name, delete the current file, or change the current file's access permission.

UPGRADE INSTRUCTIONS 

Before applying this patch, it is highly recommended that  you backup the %CROSSWORLDS%/bin, %CROSSWORLDS%/lib, %CROSSWORLDS%/WBSM and %WSWB_PATH%/plugins folders (e.g.  C:\IBM\WebSphereICS\Tools\WSWB203\plugins).  In the case you want to uninstall the patch, replace those folders with the backups.

To perform an upgrade to this version of the WBI Toolset, please follow instructions in the correct order as follows:

  1. Make sure that you have InterChange Server  and Toolset version 4.2.2  installed.
  2. Update to the InterChange Server 4.2.2.2 patch.
  3. Run the attached exe file (e.g. 4222_toolset_patch.exe).   Please notice that in the second step of the installing wizard, by default the installer enters the value of variable %CROSSWORLDS% as an installing directory name.  If you installed WBI ICS and Toolset version 4.2.2 at another location, use the Browse button to select the correct location.  The installer will do all installing work for you. 
Note that the path name "C:\IBM\WebSphereICS" assumes that IBM WebSphere Business Integration Toolset has been installed under an IBM WebSphere InterChange Server directory on the C drive. 

Below are a list of files that need to be replaced in this patch:
 
For WICS Version
Platform [Windows]
Add / Replace / Remove
File (Starting from ~/IBM/WebSphereICS/
4.2.2.2 Windows 2000/XP Replace bin/ConnDesigner.exe
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps.xml
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps_chs_chn.xml
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps_cht_twn.xml
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps_deu_deu.xml
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps_esn_esp.xml
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps_fra_fra.xml
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps_ita_ita.xml
4.2.2.2
Windows 2000/XP Replace
bin/Data/Std/StdConnProps_jpn_jpn.xml
4.2.2.2
Windows 2000/XP Replace
bin/Data/Std/StdConnProps_kor_kor.xml
4.2.2.2 Windows 2000/XP Replace bin/Data/Std/StdConnProps_ptb_bra.xml
4.2.2.2 Windows 2000/XP Replace bin/ActivityEditor.dll
4.2.2.2 Windows 2000/XP Replace bin/SMInterface.dll
4.2.2.2 Windows 2000/XP Replace lib/flowmanager.jar
4.2.2.2 Windows 2000/XP Replace lib/ConfigWizard.jar
4.2.2.2 Windows 2000/XP Replace lib/CrossWorlds.jar
4.2.2.2 Windows 2000/XP Replace WBSM/CWDashboard.war
4.2.2.2
Windows 2000/XP Replace
plugins/com.ibm.btools.csm
4.2.2.2
Windows 2000/XP Replace
plugins/com.ibm.btools.itools.datamanager

ADDITIONAL DISCUSSION




UNINSTALL INSTRUCTIONS

In part UPGRADE INSTRUCTIONS, you are recommended to backup the %CROSSWORLDS%/bin, %CROSSWORLDS%/lib, %CROSSWORLDS%/WBSM and %WSWB_PATH%/plugins folders for the purpose of uninstalling the patch.
If you have done the backup process, uninstall the patch by manually replacing the folders with the back-ups.

 

© 2004 IBM Corporation.  Proprietary and Confidential.  All Rights Reserved.