FixPack Notes for
Version 1.4.1 of the WBI Adapter for ISoft

(for CrossWorlds Infrastructure versions 4.2.x and WBI Adapter Framework versions 2.x


The patch notes contain the following sections:
 

CONNECTOR REVISIONS

UPGRADE INSTRUCTIONS

USAGE NOTES


 

ADAPTER REVISIONS

This patch contains fixes for the following CRs based on customer-reported cases

 

Available as of Version

CR Number/APAR #

Description

1.4.1

CR36128,36438,CR33728,CR37094/JR20054

 

CR36128: Fixed a problem which caused the adpater to fail during initialization when the connector-specific property ‘InputQueue’ is not configured.

CR36438: Fixed a problem in the adapter which enforced case-sensitivity of meta-object ASI and attribute names.

CR33728: Fixed a problem in the adapter which allowed incorrect caching of conversion properties when non-unique InputFormat/InputQueue values are configured in the static meta-object attributes.

CR37094: Fixed a problem which caused the adpater to incorrectly map the conversion properties to event messages when in-doubts events are being processed with multiple input queues configured for the adapter.


UPGRADE INSTRUCTIONS

To perform an upgrade to this version of the connector:

  1. Apply the changes prescribed in each table below, beginning with the entries at the bottom of each table and working up to the most recent patch. 

Add, replace, or remove the following files and directories as indicated:
 

For Adapter Version

Platform [WIN; UNIX]

Add / Replace / Remove

File (Starting from %CROSSWORLDS%/$CROSSWORLDS)

1.4.1

WIN;UNIX

Replace

/connectors/ISoft/CWISoft.jar

Add or remove the following connector properties:
 

For Adapter Version

Platform [WIN; UNIX]

Add / Replace / Remove

Property (Case-Sensitive)

1.4.1

WIN;UNIX

None

 


USAGE NOTES

CR36128:

To use the feature fixed with this update, configure the adpater without no ‘InputQueue’. Adapter will now initialize successfully with the polling feature disabled.

 

CR36438:

To use the feature fixed with this update, configure the application-specific information of the configuration meta-object (or the attribute names of the dynamic meta-object) in different cases, and the adpater will now recognize the conversion properties in a case-insensitive fashion.

 

CR33728:

To use the feature fixed with this update, users can configure non-unique InputFormat/InputQueue values in the static meta-object and the adpater will now be able to correctly identify the conversion properties for each of the business objects during request and event processing.

 

CR37094:

To use the feature fixed with this update, users can configure multiple input queues and the adapter will now be able to properly map conversion properties to in-doubt events.

 

 

 

 

 

August 8th, 2004 04:05 PM

© 2004 IBM Proprietary and Confidential. All Rights Reserved.