The patch notes contain the following sections:
This patch contains fixes for the following CRs based on customer-reported cases.
Available as of
Version |
CR Number/APAR # |
Description |
2.2.2 |
17738,21496/JR17908 |
CR 17738: The
purpose of this enhancement is to provided customers
with a way to configure the frequency that the ReplyTo
Queue is checked for incoming messages. The values for the
configurable property (ReplyToQueuePollFrequency)
is in milliseconds. CR21496: Fixed
the support for the feature which makes the ‘InProgressQueue’
configuration property of the adapter optional. |
2.2.1 |
18271 |
Corrected support for processing binary data messages in the polling cycle |
To perform an upgrade to this version of the connector:
Add, replace, or remove the following files and directories as indicated:
For Adapter Version |
Platform [WIN; UNIX] |
Add / Replace / Remove |
File (Starting from %CROSSWORLDS%/$CROSSWORLDS) |
2.2.2 |
WIN;UNIX |
Replace |
/connectors/MQSeries/CWMQSeries.jar, /connectors/MQSeries/CWJMSCommon.jar |
2.2.1 |
WIN;UNIX |
Replace |
CWMQSeries.jar |
2.2.1 |
WIN;UNIX |
Replace |
CWJMSCommon.jar |
Add or remove the following connector properties using CSM:
For Connector Version |
Platform |
Add / Remove |
Property (Case-Sensitive) |
2.2.2 |
WIN:UNIX |
Add |
ReplyToQueuePollFrequency |
2.2.1 |
WIN;UNIX |
none |
|
CR18271
For processing binary data messages see MQSeries connector guide. (Refer to section on static and dynamic meta objects and the function of the DataEncoding property in the listed table).
CR17738
To use the feature in this update add a connector application config property called "ReplyToQueuePollFrequency" which takes as it's value a number in milliseconds representing the frequency which messages will be checked for on the ReplyTo queue.
CR21496
To use the feature fixed in this update, remove the connector configuration property ‘InProgressQueue’ or do not set a value for the property.
January 31, 2003 04:05 PM
© 2003 IBM Proprietary and Confidential. All Rights Reserved.