Drop-In ID: OPDM-11.03.00-045
Product: IBM® InfoSphere® Optim™ Runtime Services
Release: 11.3.0.5a
PMR: 72964,646,706
Date: 2 April 2018
Description: This iFix applies to IBM® InfoSphere® Optim™ Runtime Services 11.3.05a only. This iFix replaces the installation script createdODPPsymboliclinks.sh that creates the symbolic links for the ODPP libraries. It then runs the script to remove the invalid symbolic links and create the correct links. This iFix will correct the following problem::
When running a Column Map function or LUA script that calls any Optim Data Privacy Providers (ODPP) in a Linux or Unix environment, a failure will occur. The trace files show that the ODPP library failed to load.
Prerequisites: IBM® InfoSphere® Optim™ Runtime Services v11.3.0.5a
Co-requisites: N/A
Supersedes: N/A
Special Notes: The only files that are replaced are createdODPPsymboliclinks.sh and rtbuild.h. The new script file ODPPFixUp.sh is added. No source code or binary module was changed for this fix.
OS Platforms: Linux x86, Solaris Sparc 32, and AIX PPC 32
Corrective Actions:
· If more than one iFix is found by Installation Manager, then all of them will be selected by default. Only iFixes specifically designed to be installed by Installation Manager, will be available. Review each iFix and unselect any that you do not wish to install.
· Ensure that all Optim components are not running before applying this iFix.
· Continue through the Installation Manager Update wizard to apply this iFix.
How to uninstall this iFix:
· Ensure that all Optim components are not running before uninstalling any iFix.
· Start IBM Installation Manager
· Select the Uninstall option from the main Installation Manager window or menu.
· Select the iFix you wish to uninstall.
· Continue through the Installation Manager Uninstall wizard to remove this iFix.
· This iFix will automatically be uninstalled if you upgrade to a new version.
If you have any questions about or problems with these procedures, contact IBM Optim Support.