IMS IC Ext 210
|
|||||
APAR | CLOSE DATE |
PTF(s) | Fixing APAR if PE |
HIPER? | Abstract |
---|---|---|---|---|---|
2005 |
THIS APAR IS A PREVENTATIVE APAR AGAINST IMS V7 PK02779. | ||||
2005 |
DEADLOCK MAY OCCUR ON RECON DATA SET USING AN ICE UTILITY JOB WITH HDPC POINTER CHECKER. | ||||
2005 |
THIS APAR IS A PREVENTIVE APAR OF IMS V8 AND IMS V9 | ||||
2004 |
WHEN ICE V2 IS CALLED FROM FPB RELOAD UTILITY, UNDER IMS V7 OR IMS V8, ICE V2 ABENDS WITH AN S0C1. | ||||
2004 |
THIS APAR IS A PREVENTIVE APAR OF IMS PQ87753 | ||||
2004 |
IEC145I 413-1C AND IFG0193A IS OCCURRING DURINGSTACK PROCESSING | ||||
2004 |
ICE CRC PROCESS TURNS OFF IC NEEDED FLAG IN DBRC. | ||||
2004 |
ICE CAN NOT HANDLE DYNALLOC FAIL OF HALDB FOR IMS V8 AND V9 | ||||
2004 |
ICE PROVIDES A NEW SKELETAL JCL FOR FABJMAIN 'GENJCL.RECOV' PROCESS. | ||||
2004 |
ICE RECOVERY FAILS WITH RC=16, IF THE RECOVERED DB IS MULTI- VOLUME OSAM AND THE DATA IS STORED INTO A PART OF THE VOLUMES. |
||||
2004 |
IMS V9 RUNUNDER SUPPORT FOR ICE V2 | ||||
2004 |
LOCEPAX=YES NOT SPECIFIED AS IEFZB505 OPTION. GARBAGE CLEANUP NOT DONE IN THE PARAMETER AREA FOR SWQMPA BEFORE CALLING SWAREQ. |
||||
2003 |
ICE RECON INTERFACE LOGIC MARKS AN ERROR IF ONE OF THE THREE RECON DATA SETS GET AN I/O ERROR EVEN IF OTHER TWO RECONS ARE OK |
||||
2003 |
ICE CONTROL BLOCKS ARE CHANGED BY APAR PQ79753 BUT SOME PARTS ARE NOT ASSEMBLED BY THE APAR, SO SOME DATA WAS NOT MAPPED. | ||||
2003 |
VALUE OF THE FILESEQ NEEDS TO BE SET TO MATCH THE CONTENTS OF THE JFCB FOR ICE V1 EXECUTION. | ||||
2003 |
ICE "CRC" MISTAKES THE HANDLING OF THE FILESEQ NUMBER IN THE CRCSTACKING PROCESS , WHEN THE OUTPUTDAT SET IS DEFINED IN JCL DD. |
||||
2003 |
ICE V2 RUNNING UNDER IMS V8 CANNOT EXECUTE WHEN TIMECHK= PARAMETER IS SPECIFIED WITH LASTIC. | ||||
2003 |
ICE INTRODUCES THE "EXTENTS=" KEYWORD THAT WILL ALLOW OSAM DB'S TO EXPAND TO UP TO 52 EXTENTS. | ||||
2003 |
PROBLEMS OCCUR IN FABJRDB7 ICE RECOVERY RESULTING IN S0C4. | ||||
2003 |
THIS APAR FIXES SEVERAL ICE V2 PROBLEMS. | ||||
2003 |
IMS IMAGE COPY EXTENSIONS V2 PROVIDES NEW COMPRESSION ROUTINE THAT REDUCES CPU TIME AND PROVIDES GOOD COMPRESSION RATE. | ||||
2003 |
ICE CRC MISHANDLES DSNAME AND UNIT NAME DATA WHEN ISSUING NOTIFY.IC | ||||
2003 |
FORWARD FIT OF APAR PQ73536 OF ICE V1. | ||||
2003 |
ICE RECOVER FUNCTION DOES NOT PULL IC DS NAME FROM CATALOG, EVEN IF CATDS IS DEFINED IN DBRC. | ||||
2003 |
ICE CRC FAILS WITH ABENDS001-05 IF THE INPUT IMAGE COPY IS FOR AN EMPTY SHISAM OR HISAM PRIMARY DATA SET. | ||||
2003 |
THIS IS A FORWARD APAR OF PQ72490 FOR ICE V1 (FMID: H1J0110). | ||||
2003 |
WHEN IC PROCESSES DEDB AREA DATA SET BY DBRC=N IN IMS V6 ENVIRONMENT, MSGDFS3708W IS ISSUED AND PROCESS ENDS WITH RC=04. |
||||
2003 |
ICE V2 ISSUES MSGFABJ0127E WHEN DSN= USES TIMESTAMP AND DSN2 IS GDG. | ||||
2003 |
THIS IS A FORWARD FIT FOR ICE V1 APAR PQ71051. ICE STACK CANNOT HANDLE THE TAPE POSITION IN PREVIOUS JOB STEPS. | ||||
2003 |
ICE V2 ISSUES MSGFABJ0105E WHEN DDN= IS NOT SPECIFIED |