Click on an APAR number to display the full information for that APAR. There may be a few days delay after the APAR closes before it is available on this website.
Click on a PTF number to download that PTF. You will need an IBMID. Latest update: 1 May 2024
IMS FP Solution Pack 120
APAR CLOSE
DATE
PTF(s) Fixing APAR
if PE
HIPER? Abstract
PI27927
9_Nov
2014
UI22879


ABEND0C4 HFPCTSK0 OR ERROR MESSAGE HFPG0009E TRYING TO CREATE SITE DEFAULT ROUTINE HFPCZZ01
PI24569
8_Sep
2014
UI21155


MSGHFPM3061E RSN: X'00000402' FROM CSVAPF, DATA SET IS NOT AUTHORIZED OCCURS
PI23537
25_Aug
2014
UI20827


RECOVERY SOLUTION PACK FAILS WITH POINTER ERRORS
PI08199
27_Mar
2014
UI16461


FPA NEEDS TO READ CI 0 TO PERFORM BETTER INTEGRITY CHECKING
PI08083
6_Mar
2014
UI15752


MSGHFPD0001I IS WRITTEN TO SYSLOG IN TWO LINES BUT SENT AS A ONE LINE MESSAGE
PI08591
7_Jan
2014
UI14051


ONLINE DATA EXTRACT (ODE) EXTRACTS THE SAME SEGMENT TWO TIMES
PI07609
18_Dec
2013
UI13657


ABENDB37-04 WITH DEDB ANALYZE UTILITY DURING VIO DATA SET ALLOCATION
PI07604
13_Dec
2013
UI13518


DURING ONLINE POINTER CHECKER RUN ERROR MESSAGE FPX0061E IS ISSUED
PI06811
12_Dec
2013
UI13468


ADDRESS ISSUES RELATED TO FPA ANALYZE
PI04733
29_Oct
2013
UI11886


ABEND0C4 RUNNING HFPMAIN0 FAST PATH ADVANCED UNLOAD DUE TO LACK OF SAVE AREAS
PM96394
24_Oct
2013
UI11629


HFPMAIN0 TO DETECT AN IMSID AS FABCUR1 DOES
PM97923
11_Oct
2013
UK98395


ABEND0C4 HFPA5SR0 + X'4DA' FOLLOWED BY AN ABENDU3006 WHEN RUNNING FPA ANALYZER WITH SEGLDIST=YES
PM96636
4_Oct
2013
UK98226


IN RUNNING OPC WITH FULLSTEP=YES, ONLY ONE RETURN CODE GETS RETURNED AS IT IS ONLY ONE STEP WITH THAT MODE
PM94821
25_Sep
2013
UK97884


LRECL FOR DFSORT SORT WORK IS VERY LARGE WHEN ODE SORT=YES IS PERFORMED
PM95893
19_Sep
2013
UK97678


RUNNING FABCUR1 RESULTS IN ABEND0C4 DUE TO LACK OF SAVE AREAS
PM92382
15_Aug
2013
UK96746


WHEN RUNNING A FP SENSOR JOB, DYNAMIC ALLOCATION FAILED FOR HFPSXXXX DDS
PM94550
7_Aug
2013
UK96473


WHEN RUNNING FPA RELOAD WITH AN INCORRECT ACBLIB, ABEND0C4 OCCURS AT HFPVMMC0 + X'930'
PM91831
30_Jun
2013
UK95559


ABENDU3301 RUNNING FAST PATH ADVANCED TOOL WHEN TRYING TO INCREASE THE SIZE OF AN AREA
PM89915
30_May
2013
UK94703


SYNTAX ERROR IS DETECTED WHEN FPXIN AND FPXOPTS DD'S ARE SPECIFIED FOR OPC (ONLINE POINTER CHECKER)
PM73630
20_May
2013
UK94440


PROVIDE SEGMENT LENGTH DISTRIBUTION REPORT AND DB RECORD LENGTH DISTRIBUTION REPORT
PM83156
15_May
2013
UK94335


SUPPORT TO RECOVER THE AREA THAT IS EXTENDED BY OAE
PM83309
15_Apr
2013
UK93490


MSGFPX0061E RECEIVED BY FAST PATH ONLINE POINTER CHECKER (OPC) DOING ANALYZE OF AN AREA
PM79336
28_Mar
2013
UK92969


ENHANCEMENT TO STORE THE SENSOR DATA WHEN USING AN IMAGE COPY DATASET AS INPUT
PM84547
14_Mar
2013
UK92496


MSGFPX0027E WITH REORGLIM=0 USING IMS FAST PATH ONLINE REORG FUNCTION
PM81036
24_Jan
2013
UK91173


REMOVE INTERFACE PARAMETER NUMBER CHECK AND SUPPORT MULTIPLE "INIT(INID)...EOF" CALLS FOR FABCUR7
PM75252
20_Dec
2012
UK90549


SUPPORT FOR IMS V13
PM76414
7_Dec
2012
UK90097


ENHANCEMENT TO SUPPORT WILDCARD OR RANGE SPECIFICATION FOR IAREA/OAREA/AREA KEYWORDS & INCLUDING TIMESTAMP WITH MESSAGES
PM77804
29_Nov
2012
UK83846


AFTER /STO REG ABDUMP COMMAND ON FAST PATH UTILITY REGION WAIT OCCURS
PM73363
31_Oct
2012
UK83120


FPA INITIALIZE COMMAND SUPPORT
PM61220
12_Oct
2012
UK82586


FPA ANALYZE ENHANCEMENTS
PM69660
14_Sep
2012
UK81808


ENHANCEMENT TO SUPPORT CONSOLIDATED LARGEST DATABASE RECORDS REPORT
PM65854
8_Jul
2012
UK80131


DEDB AREA ANALYSIS REPORT AND UOW REPORT ENHANCEMENTS
PM67683
1_Jul
2012
UK79968

HIPER

FABCUR3 DEDB AREA RELOAD FAILS WITH ABENDU3766 MSGFABC3766E
PM60111
25_Jun
2012
UK79796


SUPPORT ONLINE POINTER CHECKER (OPC) AND ONLINE EXPERT REORG (OER) TO STORE SENSOR DATA & PRODUCE FREE SPACE ANALYSIS
REPORTS
PM63408
23_May
2012
UK78971


ABENDU3769 RECEIVED ALONG WITH MSGFABC3769E WHEN RUNNING FABCUR7
PM62169
26_Apr
2012
UK78281


ENHANCEMENT TO SUPPORT MULTI-VOLUME ALLOCATION FOR THE STRIPE FILES
PM62662
25_Apr
2012
UK78252


FPA INDEXBLD/ANALYZE PROCESSES INCORRECTLY AFTER IMS V12 APAR PM44097 IS INSTALLED
PM61293
9_Apr
2012
UK77764


FPA INDEXBLD AND ANALYZE TO SUPPORT /CK NEW FUNCTION IN FPSI
PM54862
27_Mar
2012
UK77384


FPA INDEXBLD ADDS SUPPORT FOR RE-SYNCHRONIZE OPTION
PM54773
19_Jan
2012
UK75591


FPA INDEXBLD/ANALYZE ABENDS AFTER IMS V12 FPSI PM52551 IS INSTALLED
PM55367
19_Jan
2012
UK75562


ENHANCEMENT TO IMPROVE THE PERFORMANCE OF DEDB HASH CHECK INVOKED BY DRF
PM54772
16_Jan
2012
UK75454


FPA INDEXBLD TO SUPPORT THE NEW PARTITION INDEX DATABASE LIST ENTRY LENGTH THAT IS PROVIDED IN IMS APAR PM51065
PM55324
12_Jan
2012
UK75379


FP PRINTING UTILITY ENDS UP WITH ABEND0C4 WHEN THE NUMBER OF UOW IS 32766
PM55003
6_Jan
2012
UK75235


FABA4035E AND FABA4057I MESSAGES ARE SHOWN UNDER DRF HASH FUNCTION INCORRECTLY
PM50736
14_Dec
2011
UK74826


NEW FUNCTION FOR FPSP V1.2 AS DESCRIBED IN THE ERROR DESCRIPTION

Top of page