IBM(R) DB2(R) !DB/WORKBENCH Version 510 and 610 APAR PK23323 README CONTENTS 1.0 ABOUT THIS README FILE 1.1 Evaluation code 2.0 PREREQUISITES 2.1 Hardware requirements 2.2 Software requirements 3.0 INSTALLATION INSTRUCTIONS 4.0 CUSTOMIZATION INSTRUCTIONS 5.0 CORRECTIONS TO DOCUMENTATION 6.0 HOW TO GET HELP 7.0 NOTICES 7.1 Use of Evaluation Program 7.1 Trademarks and service marks 1.0 ABOUT THIS README FILE Welcome to IBM DB2 !DB/WORKBENCH Version 510 and 610 APAR PK23323 README file. This README file contains information about installing the fix for !DB/WORKBENCH APAR PK23323. The fix for APAR PK23323 has been tested and validated at PSP level 0440-1 on version 510 of !DB/WORKBENCH. This fix will be included at the next PSP. To obtain the latest PSP maintenance please visit https://www14.software.ibm.com/webapp/iwm/web/preLogin.do?source=omegamon APAR PK23323 reports that !DB/WORKBENCH reports that dataset does not exist. Problem manifests itself as From Table display enter N select for count of rows in table and product returns SFFX089M Tablespace for this table is migrated. Another symptom is issuing L (LISTCAT) select on a tablespace will result in SFFX089B Access Method Services. Data set probably does not exist. Or issue N for DS INFO on a tablespace will result in Error from AMS 1.1 Evaluation code This is not evaluation code. Please contact your IBM account representative to set up an evaluation of !DB/WORKBENCH. This code does not deliver the full product. This code delivers a fix for a specific APAR against !DB/WORKBENCH. 2.0 PREREQUISITES !DB/WORKBENCH has hardware and software requirements. 2.1 Hardware requirements Application of this APAR can be performed on any hardware system upon which !DB/WORKBENCH can run. -Approximately 10 cylinder of free disk space is needed to implement this APAR fix. 2.2 Software requirements To apply this fix you must - Be running IBM DB2 !DB/WORKBENCH at version 510. - Have Security System authority to update the product loadlib If you also have the !DB/DASD product you should obtain PK21065 and PK23338 which resolve issues with the same root cause. 3.0 INSTALLATION INSTRUCTIONS To install this APAR fix, complete the following tasks: 1. Download fix 2. Allocate receiving dataset on host 3. Transfer files to host 4. Allocate backup loadlib 5. Back-up load modules 6. Apply fix 7. Confirm fix results 1. Download fix This APAR fix is a ZIP file that can be obtained as an attachment to an e-mail or downloaded from a server. A) Create a new folder on the PC in which to save the file B) Detach ZIP file from e-mail to the new folder or download file from server to new folder C) Unzip the file 2. Allocate receiving dataset on host - hilev.PK23323.CNTL Allocate a dataset on the host with the following attributes Organization . . . : PO Record format . . . : FB Record length . . . : 80 Block size . . . . : 8880 Space TRKS 2,1,5 3. Transfer file to host Transfer all files in ASCII mode By FTP use put PK23323 put readme.txt readme 4. Allocate backup loadlib - hilev.PK23323.BKUPLOAD Allocate a PDS to backup the load modules ivolved in this APAR Organization . . . : PO Record format . . . : U Record length . . . : 0 Block size . . . . : 6144 Space CYLS 5,5,5 5. Back-up load modules Copy load modules listed from the product load library to hilev.PK23323.BKUPLOAD KTCDB2IO KTCIDCMS KTWBUDMP KTWCREAT KTWDIVGN KTWPGDMP KTW1COPY 6. Apply fix Edit hilev.PK23323.CNTL(PK23323) A) Add jobcard B) Point SYSLIB DD at product loadlib C) Submit D) Confirm that job completes condition code 0 7. Confirm fix results From Table display enter N select for count of rows in table Should get count of rows in table Issue L (LISTCAT) select on a tablespace Should get valid LISTCAT data Issue N for DS INFO on a tablespace Should get valid dataset info 4.0 CUSTOMIZATION INSTRUCTIONS The following sections describe changes to customization or installation that may have occurred after the documentation was published. This APAR fix does not impact customization. 5.0 CORRECTIONS TO DOCUMENTATION The following sections describe corrections to documentation after the book was published. This APAR fix does not require a documentation change. 6.0 HOW TO GET HELP For a complete and up-to-date source of !DB/WORKBENCH information, including information on issues discovered after this README was published, go to the following Web site: !DB/WORKBENCH Online Support: http://www.ibm.com/software/data/db2imstools/support.html !DB/WORKBENCH manuals can be downloaded from http://www-306.ibm.com/software/data/db2imstools/db2tools-library.html If you are not able to find your answer searching the listed URL, call 1-800-IBM-SERV to speak to an IBM representative for assistance. 7.0 NOTICES This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10594-1785 U.S.A. For license inquiries regarding double-byte (DBCS) information, contact the IBM Intellectual Property Department in your country or send inquiries, in writing, to: IBM World Trade Asia Corporation Licensing 2-31 Roppongi 3-chome, Minato-ku Tokyo 106, Japan The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this publication to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk. Licensees of this program who want to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact: IBM Corporation J74/G4 555 Bailey Avenue San Jose, CA 95141-1003 U.S.A. Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee. The licensed program described in this information and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement, or any equivalent agreement between us. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. All statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. All IBM prices shown are IBM's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary. This information is for planning purposes only. The information herein is subject to change before the products described become available. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrates programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the a pplication programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. 7.1 Use of Evaluation Program If you are using an evaluation copy of the program, the following terms apply: This program contains a disabling device that will prevent it from being used upon expiration of this license. You will not tamper with this disabling device or program. You should take precautions to avoid any loss of data that might result when the program can no longer be used. See the License Agreement terms that apply to the use of evaluation code. 7.2 Trademarks and service marks The following terms are trademarks or service marks of the IBM Corporation in the United States or other countries or both: DB2 IBM iSeries z/OS zSeries IBM DB2 !DB/WORKBENCH (C) Copyright IBM Corporation 2001, 2002, 2003,2004. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.