*** While the IBM Data Collection software processes do run as services under
Windows Server 2016, Microsoft disabled the ability to use the keyboard or mouse
in the services environment (aka Session 0) in this level of Windows Server. So
the DCConnect GUI, TC sessions, and adapter windows can not be acted upon or even be
switched between. So it is not practical to try to run IBM Data Collection processes
as services under Windows Server 2016.
Work is in progress to create browser-based mechanisms for performing
the monitoring and controlling of the DCConnect Server, TC and adapter sessions. In
addition, non-service programs (such as reltx32 or linetrac) will be able to
communicate with the DCConnect Server while it is running as a service.
May 2016 |
New IBM Data Collection 3.1.0 CD available
for entitled customers for (Windows NT/2000/XP/7/Server).
New features and fixes are provided for the DCConnect Client, the DCConnect Transaction
Building Tool (aka DCTPB), DCConnect Server and User Interface, Transaction Connection,
the JD Edwards Adapter and the TCP/IP Manager.
Fixes/changes since the 3.0.9.1 CD are provided for the following key areas plus other minor
ones not mentioned here:
- DCConnect Client enhancements
- Added support for loading a new version of the Client or its files (e.g. emulator.ini) from
the DCConnect Server. This includes support for the emulator.ini keyword,
USE_ROOT_FOR_DOWNLOAD_FILES=Y, for any device that has slow non-volatile memory affecting the
download.
- For the SenRead API, the first byte returned, which is the symbology ID, now supports
DATAMATRIX (34), QR_CODE (35) and MAXICODE (36).
- Added support for the keyword SCAN_LOOK_FOR_AIM_CODE (Y/N) which tells the client to
look for the ] character at the front of the scan string and if found, interpret the following
characters as an AIM standard symbology identifier.
- If downloaded validation files contain passwords or other info that should not be readily
readable on the client devices, the new optional parameter, DELETE_UNZIPPED, can be specified
for the LOCAL_VALIDATION command that is used to specify which validation files should be
downloaded to client devices when text-based scripts are used.
- The DCConnect Client now looks for and ignores imbedded end-of-file characters found while
processing text-based scripts files.
- DCConnect Server and User Interface enhancements
- Added ability to have mailbox data persisted in ODBC database tables as an alternative to the
long used flat file mechanism. Either option can be used.
- Added the abiity to have master-child mailbox relationships for the purpose of load balancing of
transactions.
- Added new variation of API for writing transactions: DcxWriteTransactionEx2 which adds new parameters
for Serial_Key and Priority which are used when Master-Child mailboxes are set up in order to control
how transactions are handled by the children of a particular master mailbox.
- Added the ability to download new versions of the DCConnect Client to terminals running
version 3.1.0 or later of the DCConnect Client.
- Added the API DcxQueryTermList for getting the entire list of valid terminals in the DCConnect configuration. Similar to
DcxQueryJobTerms but not limited to a single job.
- The downloading of text-based files now strips out any end-of-file characters it encounters at the
start or end of a line in the source files.
- Added ability to change polling and in/out service state from the node level, adapter level or line level of
the Node Configuration graphics view. This now gives a single place to stop/start polling for all terminals.
- For support of DCConnect Client file downloads, the Details view of the Node configuration screen now
shows the version of DCConnect Client for each terminal.
- Transaction Connection enhancements
- JD Edwards Adapter enhancements
- Added support for IGNORE_BOD_LOG_PARAMETERS = Y in adapter session-specific .INI files (e.g. OneWorld01.INI). If
this parameter is in effect, then the adapter will ignore any logging parameters that are sent to it in SYNC_LOGON
and SYNC_ADAPTER BODs.
- Added the ability to override adapter behavior in response to particular ODBC errors using the new
ODBC_ERROR_ACTION parameter in the same adapter session-specific .INI files (e.g. OneWorld01.INI).
- The GET_LIST BOD now updates its 'last busy' time during processing, allowing its processing to
exceed the ThreadDeath / RestartForOldThreads / KillOldThreads thread timeout as long as it is actively fetching
records and generating output.
- PUT_LIST BOD now supports performing multiple database operation statements in a single BOD, and/or
multiple ROWs within an INSERT statement.
- Added the VERSION and VERSIONNUM attributes to the CONFIRM section of the Confirm BOD response to TC (the
same section where STATUSLVL is) - so that version specific differences in reply formats can be handled.
- Efficiency changes made for the set of JDE business calls made while processing the Issue Inventory BOD.
From one third to one half of the business function calls have been eliminated by removing duplicate calls when the
branch or the branch / item / lot are the same for other items in the BOM.
- The ENVIRON element of the DBLOGONID and LOGONID elements of the SYNC_LOGON BOD can now be set at the higher
level, one time, and will then be applied to all DBLOGONID and LOGONID elements.
- Added ability to have the Adapter request a new JDE session ID based on a session usage time limit, upon
request via the Sync_Adapter BOD, or interactively by pressing the 'S' key on the console. This is intended to
allow JDE kernel processes to end as their last using session disconnects. The usage time limit may be set via a
command line parameter (SESSIONAGELIMIT=[# minutes]) or via a SESSIONAGELIMIT element in the Sync_Logon BOD.
- Added UNEXPECTEDWINDOWS.INI to optionally configure handling of pop-up windows.
- Added IGNOREHOLD optional element on ship_salesorder BOD to ignore F4201 HOLD value.
- Improved shut down processing while waiting for threads to complete their work; some resources were being freed
right away, sometimes affecting those threads.
- TCP/IP Manager enhancements
- Corrected display of IP addresses in some messages.
- Some timeouts were adjusted to improve efficiency.
|
March 2014 |
New IBM Data Collection 3.0.9.1 CD available
for entitled customers for (Windows NT/2000/XP/7/Server).
New features and fixes are provided for the DCConnect Client,
DCConnect Server and User Interface, Transaction Connection,
the JD Edwards Adapter and the TCP/IP Manager.
Fixes/changes since the 3.0.9 CD are provided for the following key areas plus other minor
ones not mentioned here (see the links at the top of this page for all detailed changes):
- DCConnect Client - Enhancements through version 3.0.9e
- Added support for handling configuration commands for those flavors of the Client
that support direct loading from text-based script files. These commands include
COMMUNICATIONS_TIMEOUT, DATE_SEPARATOR, and RS232_BAUD_RATE. The complete set is
documented in the Data Collection Transaction Program Builder User's Guide (dctpb32.htm).
- Added support for handling compressed files downloaded from server when in text file mode.
Compression is handled for the text file, validation files and the CFR. Requires server files
from February 2014 as well.
- DCConnect Server and User Interface - Enhancements through version 3.0.9b
- Implemented compression of downloaded files for terminals running version 3.0.9b and later of the Client - when
loading text-based files. Compressed files, when in text-based mode, includes the CFR and any validation files.
This should decrease download size and times to about one fifth or better as compared to non-compressed downloads of
the same files.
- DCConnect Server version and copyright now logged on startup.
- Also increased the size of CFR download messages that are sent to the DCConnect Client (on a
TCPIP/IP line) so that fewer download messages are needed for the CFR download (about 1/4).
- Transaction Connection - Enhancements through version 3.0.9d
- New SCRIPTS option available for the second 'which_files" parameter of the Load_Term command. This can only
be used when the target terminal is loading the text scripts directly. This option indicates only the scripts should be
loaded; no CFR or validation files should be loaded.
- New command XML_LoadLoggingParameters gives TC sessions the same capability to specify unique logging
parameters for XML message processing - that the recently introduced .INI file capability does for the adapter and
TCP/IP Manager:
- XML_LoadLoggingParameters ( Parameter_File * )
- New Trace_Delay_Limit compile-time configuration statement allows configuration of the slow trace
delay accumulated during a sampling period, and trace will now be re-enabled automatically after a configurable
delay/stabilization time.
- Added new commands XML_DefineNamespace and XML_RedefineNamespaces.
- JD Edwards Adapter - Enhancements through version 3.0.9c
- Eliminated the use of inter-process sharing of logging parameters. With the use of the .INI
file for logging parameters, introduced in version ADP 3.0.8s / TCP 3.0.8g, this should prevent the cross-logging of
messages into logfiles for a different adapter.
- Added new RestartForOldThreads command line option as an alternative to KillOldThreads because if
a thread has to be killed, any resources it owned remain locked and any flags it had set are not cleared when
it is killed. So it is better to restart the adapter if any thread is deemed to have taken too long to complete
its work. This results in a cleaner recovery. Note that upon shut down of the adapter, the adapter will
wait up to the default of 30 minutes (or the ThreadDeath value specified on the command line) for threads to
end themselves. So when using RestartForOldThreads, you should also explicitly set ThreadDeath to a very low value
such as 1 or 2 minutes so that the adapter does not wait the additional 30 minutes before shutting down - on top of
the time it waited for the old thread to complete its work (i.e. the value specified for RestartForOldThreads).
- TCP/IP Manager - Enhancements through version 3.0.9a
- Eliminated the use of inter-process sharing of logging parameters. With the use of the .INI
file for logging parameters, introduced in version ADP 3.0.8s / TCP 3.0.8g, this should prevent the cross-logging of
messages into logfiles for a different adapter.
|
November 2013 |
New IBM Data Collection 3.0.9 CD available
for entitled customers for (Windows NT/2000/XP/7/Server).
New features and fixes are provided for the DCConnect Client, the DCConnect Transaction
Building Tool (aka DCTPB), DCConnect Server and User Interface, Transaction Connection,
the JD Edwards Adapter and the TCP/IP Manager.
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
- DCConnect Client enhancements
- Support added to directly load script files (.COD) that previously had to be compiled by DCTPB
- Support added for multiple-languages being loaded into the terminal at once with new commands:
Start_Language, End_Language and Set_Language.
- New ENCRYPT command to enable use of the Blowfish encryption algorithm
- Added support for CFR_FILE, LOCAL_VALIDATION, SYSTEM_MESSAGE and BUFFERING_MODE
- Named messages can now be 64 characters instead of 32.
- The 3rd parameter (length) is now optional for the MESSAGE command
- Comments are now allowed in the middle of commands that span multiple lines.
- A single command including white space and spanning multiple lines can now be up to 4000 characters; was 1024.
- Label resolution is now case-insensitive.
- The new Version command allows Client and Server to check if the Client has the latest scripts.
- Maximum length allowed by APNDSTR/SETSTR changed from 256 to 999.
- Better detection of missing parenthesis at end of Declare command and better reporting of the line # when
parenthesis missing for any command.
- New QUERY command to get information about a user variable or the Client environment. Options include: LENGTH, IS_NUMERIC,
IS_NUMBER, NUM_ROWS, NUM_COLUMNS, CURSOR_ROW, CURSOR_COLUMN, DATE, or KEY_NAME_VALUE.
- Added "quick" keys to bring up the Start Stepping (@) and View User Var (#) screen in the menus.
- Fixed the handling of the R key in stepping mode.
- Arrow keys can now be used to move the "view port" for the menus just like they have always been able to be used to move
the view port of the main transaction program screen.
- New Terminal Name Resolution feature to allow VPN-connected devices to communicate with the DCConnect Server even though
they do not have a fixed IP address or hostname.
- The LOCK_IN_MEMORY keyword in EMULATOR.INI can now include a list of program numbers (1-121) or key names (F1, F2, PF1, ADDL1, ... - the same ones used
for the AKA command) in addition to (or instead of) validation file names. Programs that are most commonly used, such as those that include common
subroutines, are ideal candidates for being locked in memory. This will improve performance.
- The MENU_KEY keyword for EMULATOR.INI now allows extended keys to be specified by putting X followed by the decimal value of the high order
byte for the extended key code.
- Fix for use of F11 and F12 keys on Windows CE flavors of the Client.
- DCTPB enhancements
- Added support for new QUERY and ENCRYPT commands and other features recently added to the DCConnect Client:
- Named messages can now be 64 chars
- The 3rd parameter (length) is now optional for the MESSAGE command
- Comments are now allowed in the middle of commands that span multiple lines.
- A single command including white space and spanning multiple lines can now be up to 4000 characters; was 1024.
- Label resolution is now case-insensitive.
- The new Version command implemented for the DCConnect Client direct-compile of scripts is specifically ignored by DCTPB.
- Maximum length allowed by APNDSTR/SETSTR changed from 256 to 999.
- Better detection of missing parenthesis at end of Declare command and better reporting of the line # when
parenthesis missing for any command.
- DCConnect Server enhancements
- Added support for downloading .PGM files with the new ENCRYPT and/or QUERY commands.
- Added support for downloading text-based scripts for the new capability of the DCConnect Client to read script
files directly, including versioning and compression.
- New Terminal Name Resolution feature to allow VPN-connected devices to communicate with the DCConnect Server even though
they do not have a fixed IP address or hostname.
- DCConnect User Interface enhancements
- Added support for Terminal Model and Settings Source in Terminal Settings Notebook
- Text views for Node / Mailbox / Function Group configurations now sort entries by the names of the terminals / mailboxes / function groups.
- Fix for configurations containing DWTS terminals. GUI would throw an exception and end or hang if loading a
configuration containing DWTS terminals or if trying to add DWTS terminals to a configuration.
- Transaction Connection enhancements
- TC's versioning is now in line with the other products: 3.0.9. Previously
the version had gotten to 3.3.4 before being brought in line.
- TC now automatically remembers its window size and position based on its controller ID.
- TC now resizes both the Execution pane and the Messages pane whenever the TC window is resized.
Which of the panes are resized can now be controlled via the 3 new script commands: Resize_Both_Panes,
Resize_Messages_Pane_Only and Resize_Execution_Pane_Only.
- Set/Append_UV_Data_Part and Set/Append_Xact_Data no longer require the start and length parameters.
- New Data Parts: EXECUTION_TIME_TOTAL, EXECUTION_TIME_EXTERNAL, EXECUTION_TIME_LAST and IDLE_TIME.
- XML_Configure now handles the following logging related options: LogLevel, LogFile, LogSize, LogCount, Debugfile,
DebugSize and DebugCount
- Added the ability to define web services via an XML file instead of in a database table.
- Enhancements to interfacing with WebSphere MQ
- New XML_Configure options: IncludeFinalNull, UseCorrelationID,
- New commands: XML_AddAttribute, XML_ToString, XML_ToFile, XML_CopyElement, XML_GetField2, Define_Large_UV_Size,
- New commands for interfacing with Active Directory: LDAP_AdminBind, LDAP_AdminUnbind, LDAP_ValidatueUser, LDAP_Search,
LDAP_Encrypt, LDAP_ChangePassword.
- Fix for XML_SetField. It was appending to existing data in the field rather than replacing it.
- Enhancement made to the System() command to launch applications in the true 64-bit environment if it is detected that TC
is running on a 64-bit version of Windows.
- Fix for intermittent false positive database fetches that actually had no records returned.
- Also implemented feature where trace logging is disabled if TC detects it is negatively affecting performance.
- JD Edwards Adapter enhancements
- Fixed the recovery process from ODBC errors for the GetColumnSpecs function.
- Redesigned the message buffering mechanism to resolve mutex errors that resulted in certain threads hanging.
- Fixed problem that slowed communication because transfer between internal queues was not acted on right away.
- Fix for mutex errors related to ReadQueue or WriteQueue.
- Fixed possible cause of exception if any JDE database column name is longer than 10 characters.
- Made the following enhancements to logging for both the adapter and TCPIP Manager:
- The LogLevel can now be set differently for different adapter sessions and even the TCPIP Manager - using the
.INI file scheme described in the following bullets.
- The following logging parameters can now be read from an .INI file: LogLevel, LogFile, DebugFile, LogCount,
DebugCount, LogSize, DebugSize, Debug, Dont_Print_Pointers, DBG_ALL_JDE_XML and DBG_WARN_JDE_XML.
- After the Adapter / TCPIP Manager are started, the R key can be pressed to trigger the Adapter / TCPIP Manager
to reread the .INI file. The use of the .INI files and R key should replace the tools DebugOn / DebugOff as the
way to change the logging settings for a running adapter / TCPIP Manager.
- For the ODBC implementation of the GET LIST BOD, the maximum data size supported was increased from 255 to 4096 characters.
- A new command line option 'UseF98611' can be specfied to indicate that the adapter should further
map a DATP data path found for a table in the F986101 to a 'real' ODBC data source name and libarary found in
the F98611's DATB and DATB2 columns, respectively, for that DATP value. This is would be set to 'Y' in a
JDE 9.x environment with the data on an IBM iSeries (AS400). This can greatly reduce the number of ODBC DSNs
that need to be configured, and reduce the total number of connections that the adapter opens.
- TCP/IP Manager enhancements
- Fixed one cause of TCP/IP Manager "memory block" errors.
- Fixed causes of high CPU usage by the TCP/IP Manager.
- Fix for problem where TCP/IP Manager would hang on shutdown when X was pressed to stop it.
|
March 2012 |
New IBM Data Collection 3.0.8 CD available
for entitled customers for (Windows NT/2000/XP/7/Server).
Note: Several other 3.0.x instances of the CD were also created in the
time between the 3.0.0 and 3.0.8 CDs. The lists of enhancements covers the
3.0.1 through 3.0.8 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection, the DCConnect Transaction
Building Tool (aka DCTPB), the JD Edwards Adapter, the TCP/IP Manager and
DOS/Windows Terminal Services.
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
- DWTS enhancements
- The CD now includes a sample Java application that uses DWTS APis
to communicate with the DCConnect Server.
- DCTPB enhancements
- Fix for compiling IF commands that reference named messages; prior
to the fix an "Invalid comparison syntax" error was given.
- Transaction Connection enhancements
- Added support for web services - TC scripts can now be a provider
or a consumer of web services.
- Added capability for multiple ODBC data sources
- Begin/End_SQL supports "{Call form of Oracle stored procedure
invocation as a type of select statement
- Fixed initial database connection so it retries recoverable errors
- Added some new retriable connection error options in rc_odbc.ini:
RECONNECT, RESET_RECONNECT and DELAY_RETRY.
- New data part: LAST_DS_ALIAS
- TC now has the ability to cancel an XML send request that is
taking too long. A new ADPTUtiL.DLL is needed as well.
- Begin/End_UV uses max size buffer (32K), rather than smaller SQL
buffer (4K)
- The trace info for XML_Cleanup now logs the handle value
- Added auto-cleanup of XML handles
- For multiple ODBC connections, only re-connect the DB connection
involved in an SQL error rather than re-connect all connections. Force
any open result set to be obsoleted if the associated DB connection
had to be re-connected between fetches (causes sql error if you do
xxx_UV_Select_Data after re-connect).
- DCConnect Server enhancements
- The download process now properly handles message number
resolution for named messages used in IF, CALL/GOSUB and RETURN
transaction program commands.
- Hostname resolution was enhanced to handle the case where the
DCConnect configuration has a fully-qualified hostname.domain set for
the address when a message from the network resolves to the same
hostname - but without the domain. Previously this was not considered
a match. Now the server will look for all terminals in the DCConnect
configuration that have a matching hostname (there may be more than
one, each with a different domain) and issue a request to resolve the
fully qualified hostname.domain for each.
- JD Edwards Adapter enhancements
- Workaround to handle audited JDE tables. Audited tables are
renamed with the suffix _ADT and a view is created with the original
name. Views do not have primary keys, so the adapter must now handle
the _ADT suffix when it is told a 'table' has no primary keys.
- Log level 150 now available to get more detail about database
operations.
- Added blank line and timestamp to screen output at the start of
the processing of a new BOD. Execution time output also now has a
timestamp.
- Fixed one cause for adapter not fully shutting down even after it
displays "Really done now" message.
- Passing of values between business functions was not working for a
Call Function BOD with multiple calls. The first character of the
field name was being chopped and so it could not be found.
- JDE responses to UBE requests were not being inspected for errors.
UBE errors are now treated like any other JDE error.
- Added handling of the JDE XML error: 'Network communication is
broken'. When encountered, the session ID is cleared and the business
function is retried automatically. One case where this error can occur
if the JDE service on the JDE server is stopped and restarted between
calls to JDE.
- The adapter now sets the 'role' parameter in the XML header to
'*ALL'
- The adapter now handles recycling of the ODBC connection for some
additional SQLSTATE/Native Error codes (HYT01/*, HY000/3114,
HY000/3135, HY000/12541)
- Fix for contention between adapter sessions when buffering of BODs
to prevent duplicate processing actually caused processing to be
skipped in some cases. Because operating system resources such as
named shared memory and named semaphores were not being uniquely
identified between adapter sessions, the same memory/semaphores could
occasionally be used by multiple sessions at the same time.
- Fix for handling imbedded single quote characters in SQL
statements generated by the adapter - whether selects, inserts or
updates. When character data includes single quotes, they must be
encoded as back-to-back single quotes since the entire character
string is enclosed in a pair of single quotes.
- Fix for handling the JDE data type EVDT_VARSTRING for the PUT LIST
BOD. Previously an exception occurred when trying to update a column
of this type or any other unexpected type. Updates were also made to
gracefully handle returning an error if another unexpected data type
is encountered.
- Added handling of the JDE XML error: 'The dispatcher gets timed
out'. When encountered, the session ID is cleared and the business
function is retried automatically.
- Fixes for properly handling recovery after ODBC errors; previously
handles were being freed in the wrong order.
- New logging options DBG_ALL_JDE_XML and DBG_WARN_JDE_XML for
debugging JDE XML messages. Now the XML from all JDE errors are logged
to logfile (before the adapter would not log XML for all errors
because JDE would sometimes return 0 when the response actually
contained errors). Plus not all JDE XML warnings and messages were
being returned in the Confirm BOD.
- Many JDE errors (e.g. XML parse error) will be categorized as an
L005 fatal error. This is returned in the response BOD's REASON_CODE
element and can trigger an adapter restart if the L005 related adapter
parameters are configured to do so.
- Added support for configuring ODBC error actions via the
configuration file ODBCErrorActionst.ini.
- Fix for handling XML system type errors vs JDE business function
errors. L002 or L005 is returned as REASON_CODE only for XML system
errors - not JDE business function errors.
- Fixed one cause for "All Logons in Use" errors that persist after
adapter is unable to connect to the JDE database - even after the
database recovery has completed successfully. The fix also handles
situations in which connectivity is to older versions of JDE where
database access was through the JDE API rather than ODBC.
- Fixed problem with incorrect JDE table/structure information being
cached if an SQL error occurred When retrieving that information.
- For the CALL FUNCTION BOD, a new parameter can now be specified
for each function (same level as FNNAME and DSNAME) called
IGNORE_ERRORS_IF_ZERO_RC. If set to TRUE or YES, there will be no
check made for any JDE error messages if the return code from the
business function call is 0. There are cases where the internal
processing of a business function can cause warnings or even errors
generated but the final return code ends up being 0. If in this
scenario, the errors should be ignored by the adapter, the adapter
will return no error in the BOD response.
- TCP/IP Manager enhancements
- TCPIP Manager now tries up to 5 minutes to resolve host name - to
handle the case where TCPIP Manager running as a service is started
before the necessary network drivers/services are running to the point
where a host name can be resolved.
- TCPIP Manager now tries for a maximum of 5 minutes to send a
message to the target server. After this time-to-live timeout the
message is discarded - the assumption being that the message is no
longer being waited for. The time-to-live is based on when the message
is created. In the case that the message is a response to a request,
the start time is based on when the response message was created, not
when the request message was created.
|
February 2010 |
New IBM Data Collection 3.0.0 CD available
for entitled customers for (Windows NT/2000/XP/7/Server).
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection and the DCConnect Transaction
Building Tool (aka DCTPB).
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
- Installation enhancement
- The installation has been redone with the latest level of
InstallShield in order to handle 64-bit Windows environments.
- Transaction Connection enhancements
- Title statement fixed to affect the Title on the window
- Added set of Last-Error Data Parts for several DCConnect API
functions
- During compile, uncalled subroutines and unreferenced labels are
listed
- Fix to alleviate problem with 'empty' compile window from being
unendable
- Fix for various traps during shut down: When Logoff script has
Goto into the middle of a subroutine, When data request read is
hanging, and Premature thread termination when Make_Data_Request used
in Logoff
- Fix to Open_File_Data when internal file handle happen to be 0
- Set/Append_UV_File_Data now truncates data read at null, if one is
found
- New REPLACE option for the Format_UV command
- System command can now timeout and no longer brings up window in
foreground
- Controller IDs can now be 1 or 2 characters
- Trace infrastructure uses process Id instead of controller ID to
avoid conflicts
|
November 2008 |
DCConnect Client version 3.00 now available
for entitled customers
This addresses the following issues (plus some other more minor issues)
since version 2.30e
- Better fix for cursor disappearing on Windows CE devices (2-22-08
fix had problem with extra cursors showing up).
- Added support for the VOLUME keyword in EMULATOR.INI for Windows CE
devices. See the DCConnect Client User's Guide for more information.
- Added support for the TURN ON / OFF CMD LOG option in the
DIAGNOSTICS menu for Windows and Windows CE devices.
|
March 2008 |
DCConnect Client version 2.30e now available
for entitled customers
This addresses the following issues (plus some other more minor issues)
since version 2.20
- Antares terminals can only work with whole numbers in MATH, FRMT and
IF commands.
- IF commands can now be used, along with the TEST command, to look at
unpassed parameters in a subroutine. Also an unpassed parameter from one
subroutine can be passed to another nested subroutine.
- Commands such as CURS, SHOW, DLAY that use variables for their
parameters now accept values that contain a decimal point as long as all
digits after the decimal point are 0.
- A SKIP operation that results from a command such as CCFR, VRFY or
TEST, will now skip the entire IF/ELSE construct if an IF command is
what follows the CCFR/VRFY/TEST command.
- Fixed cause of eventual filling of user variable pool if Esc is
pressed to end a transaction program.
- The source and target of an APND or SET command can now be the same.
In the case of a SET command, the result is that the variable is not
changed. In the case of an APND command, the result is that the contents
of the variable are duplicated.
- Sped up the return from subroutine calls.
- For Windows CE flavors of the Client, sounds are now generated as
.WAV files allowing for variation in the frequency and duration. Before
all application-generated sounds were the same tone and duration.
- Workaround implemented to handle CE devices with Hi-Res displays
which don't provide true fixed character width fonts.
- Added support for MAPPED_KEY keyword in EMULATOR.INI. Use it to map
the ASCII value of one key to another. Extended keys may be mapped to or
from as well. For example to map the A key (ASCII 65) to the B key
(ASCII 66): MAPPED_KEY 65, 66.
- CFR temporary file now written to root directory on Windows CE
devices because certain devices (e.g. Symbol WT4070) had periodic slow
write times to the non-volatile storage, causing downloads to fail due
to a failure to respond to the DCConnect server in time.
- Better use of screen width when number of columns is an odd size
such as 31.
- Added support for IGNORE_KEY keyword in EMULATOR.INI. See
documentation for usage.
- The default for the RESEND_TIMER is now 5 seconds for TCP/IP flavors
of the Client. The default for serial versions is still 25 seconds.
- Added new key options for use in stepping mode:
- 1-9,0 = Skip 1-10 steps
- S = Skip current subroutine. Only valid when stopped at a GOSUB or
ONSUB command. All commands are processed in that subroutine as well
as any subroutine(s) that it calls. Stepping pauses at the command
following the subroutine call.
- R = Return from the current subroutine. Only valid when in a
subroutine. Commands are processed up to and including the RETURN
command. Stepping pauses where the subroutine returns.
- B = Leave the current (if or else) block. Stepping resumes after
the end block command (}) that ends the current block. Any other
blocks that are entered will be exited on the way to the target end of
the block.
- Fix for handling of the if-else flow control when a goto command
branches backwards in the program.
- Fix for beeps. Conversion from 0.1 second to 0.25 granularity was
resulting in 0 length beep for 0.1 and 0.2 seconds. Now all values are
rounded up to the nearest 0.25 second.
|
February 2008 |
Fixpack 2.3.0 available
for entitled customers for (Windows NT/2000/XP/7/Server) products on
the DCConnect 1.4.0 CDs and the IBM Data Collection 2.0.0, 2.0.1, 2.1.0 or
2.20 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection and the DCConnect Transaction
Building Tool (aka DCTPB).
This fix pack brings these products up to the same level as version
2.3.0 of the IBM Data Collection CD.
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
- DCTPB enhancements:
- For the GOTO / GOSUB commands, the first parameter is now optional
if it would be THIS_PROGRAM and no other parameters except for the
step/label are provided. In other words, if THIS_PROGRAM is the target
program, then only one parameter is needed - the target step or label.
- Fix for compiling IF statements comparing to a string containing
imbedded blanks.
- Added warnings for subroutine calls that have fewer parameter than
the subroutine definition (this is allowed but user should verify all
occurrences are expected).
- Added named message support.
- MESSAGE commands are now included in output when SHOW_STEPS is
used on the command line.
- Transaction Connection enhancements:
- Added support to the XML_Send command so that "raw" messages can
be sent, not just those that are XML formatted.
- Added support for new Format_UV options: ASCII_TO_EBCDIC,
EBCDIC_TO_ASCII and LOWER_CASE.
- New version of TC is now 'service-aware' so that it can run as a
service and can respond cleanly to service start/stop commands.
- Fix for buffer overrun that caused TC to end abruptly during a
Check_Color command.
- DCConnect Server/User Interface enhancements:
- On server startup, a time synch is now scheduled for all 7527 and
7524/DCClient terminals. This was done because time synch requests are
not preserved across server shutdown/startup for these terminal types.
- New versions of DCCLEVEL.EXE and DCCSERVE.EXE run better with
newer versions of Windows such as XP and 2003 Server.
- New logtool.exe for recovering transactions from logfiles. See
DCConnect User's Guide for the details.
- Fixed hostname resolution problem when the resolved name included
the domain. Fix for handling aliases as well. New message shown for
all IPs that resolve to names.
- Fixed problem in dccserve.exe when starting the DCConnect service
using the NET START command.
- Removed arbitrary 256 terminal limit for TCP/IP 75xx and TCP/IP
DWTS lines.
- Better handling of very long parameters on a message continuation.
|
October 2005 |
Fixpack 2.2.0 available
for entitled customers for (Windows NT/2000/XP) products on the
DCConnect 1.4.0 CDs and the IBM Data Collection 2.0.0, 2.0.1 or 2.1.0
CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection and the DCConnect Transaction
Building Tool (aka DCTPB).
This fix pack brings these products up to the same level as version
2.2.0 of the IBM Data Collection CD.
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
- DCTPB enhancements:
- Fixed corruption problem that results for first subroutine
assigned to a transaction program key, if that key has a program
assigned as well and that first subroutine has more than one local
variable declared. Could result in a Parameter out of Range error on
the terminal or manifest itself in other ways.
- Fixed problem doing variable name substitution (to variable
number) for CCFR commands.
- Fixed problem naming user variable 99.
- Added support for IF, ELSE, { and } block commands. See the
documentation for all the details.
- DCTPB now always adds a RETURN(uvRC) to the end of every
subroutine; before this was done only when the last command was not
RETURN. Adding the RETURN all the time takes care of the case that the
second-to-last command caused the final RETURN to be skipped (e.g.
CCFR, TEST, VRFY, ...)
- Added the optional SHOW_STEPS command line option to DCTPB32.EXE.
If present, DCTPB will show the program number and assigned step
number for every command as it compiles your transaction program(s).
This can be useful when trying to cross reference your DCTPB source
code with DCConnect Client generated messages or error transactions
which reference a step number.
- DCConnect Server / Transaction Connection enhancement to handle
transactions with up to 750 bytes of data. Other changes that go along
with this include
- Transaction logfile now contains variable length records instead
of fixed length records.
- Mailbox logfile capacity is now specified as number of bytes and
can be in the range from 100,000 - 25,000,000 bytes.
- The Server will automatically convert logfiles in the original
fixed length format to the new variable length format and will adjust
to the minimum size as necessary. However, as has always been the
case, logfiles are not resized if they contain transactions at startup
of the Server.
- On the Mailbox Configuration screen the 'Capacity' column is now
called 'Capacity Used' and it shows the usage in the format "xx% of
yyyyy" where 'xx' is a percentage from 0-100 and 'yyyyy' is the
defined capacity in bytes. The other columns (Mailbox Name, Status,
Read and Release) still show the same information.
- For all devices running version 2.10c of the DCConnect Client or
later, the logfile size for that device can now be set from the
DCConnect User Interface in the Terminal Settings notebook (just like
was done years ago for the IBM 7525, 7526 and 7527 terminals). Go to
the second page of the General Tab and look for the Buffer Size box.
You can choose "Don't Change" or you can choose "Size (Kbytes)" and
then select a value from 1-64 indicating the number of Kbytes (1024
byte chunks) that should be allocated on the terminal's 'hard drive'.
- There will always be at least 1 unused byte in the logfile.
- If you are writing your own C / Basic / Rexx / ... server-side
applications there are now new structures and APIs defined in DCX.H
that are available in order to take advantage of the longer
transaction features:
- TRF2 is the new transaction structure. It not only allows up to
750 bytes of data in the .txdata field but it now uses a long integer
for the .datalen field and it has six new fields for the adjusted
date/time (.yearAdj, .monthAdj, .dayAdj, .hourAdj, .minuteAdj,
.secondAdj). These size fields are for storing the adjusted date/time
for transactions that come from terminals in time zones that are
different from the server's time zone (as defined by each terminal's
configuration). The original date/time fields (.year, .month, .day,
.hour, .minute, and .second) contain the data/time for the originating
terminal's time zone. The server takes that date/time and adjusts it
to the Server time zone and stores those values in the adjusted
date/time fields.
Both of the year fields (.year and .yearAdj) now store the 4-digit
year instead of just the 2-digit year.
- DcxReadTransactionEx is the new counterpart API to
DcxReadTransaction and it must be used in order to read in the longer
transaction structure
- DcxWriteTransactionEx is the new counterpart API to
DcxWriteTransaction and it must be used in order to write transactions
with longer data or with a 4-digit year or with the new adjusted
date/time fields.
DcxWriteTransactionEx now has an extra parameter that allows you to
specify a list of mailboxes rather than having to specifying a valid
terminal name. If this parameter is NULL, a valid terminal name must
still be provided.
- A new structure, QUERY_EXPORT2, is the counterpart to the original
QUERY_EXPORT structure. It adds one more field: .percentFull.
- DcxQueryMailboxEx is the new counterpart to DcxQueryMailbox and it
must be used in order to get back the new QUERY_EXPORT2 structure with
the new .percentFull field
- The .size field of both QUERY_EXPORT and QUERY_EXPORT2 specifies a
number of bytes rather than a number of records.
- In Transaction Connection, the Write_Xact command can take
advantage of the new DcxWriteTransactionEx API, allowing you to
specify one or more mailboxes for the destination of the transaction
record rather than having to specify a valid terminal name. In this
case you can pass what you want for the function group name and
terminal name. Note that TC had always ignored the function group
parameter in the past because the DCConnect Server would override it
based on the specified terminal.
- TC gives you access to the new adjusted date time fields from the
new transaction record structure (TRF2) with addition of the following
data parts (ADJDATE4, ADJDATE, ADJTIMESTAMP4, ADJTIMESTAMP, ADJYEAR4,
ADJYEAR, ADJMONTH, ADJDAY, ADJTIME, ADJHOUR, ADJMINUTE, ADJSECOND).
The regular transaction data parts for date/time (all of the above
without the leading 'ADJ') will get their values from the original
(non-adjusted) date/time fields in the transaction record unless the
keyword USE_ADJUSTED_XACT_TIME is in effect.. When that keyword is in
effect, the regular transaction data parts for date/time will get
their values from the adjusted date/time fields in the transaction
record. In all cases you will be able to get the non-adjusted
date/time fields by using the following new data parts (TERMDATE4,
TERMDATE, TERMTIMESTAMP4, TERMTIMESTAMP, TERMYEAR4, TERMYEAR,
TERMMONTH, TERMDAY, TERMTIME, TERMHOUR, TERMMINUTE, TERMSECOND).
- The XACT_AGE data part and the Xact_Age command are also affected
by the USE_ADJUSTED_XACT_TIME command; when it is in effect the
transaction age is calculated using the server adjusted date and time.
- In TC the Query_Mailbox command now accepts a 6th parameter which
lets you receive the percentage full of the mailbox.
- The newer TC will work with older versions of the Server that do
not have the newer APIs needed for longer transactions. Of course in
this case, your TC scripts won't be able to take advantage of any of
the newer features. (TC tries to load the newer APIs from the
DCConnect Server .DLL but if not found, no error is given - unless the
scripts try to use a feature that requires the newer APIs).
- Older versions of TC will work fine with the newer DCConnect
Server as long as no transactions exceed the previous maximum length.
- Older versions of the DCConnect Client will work properly with the
newer DCConnect Server; in this case the Client will ignore a request
by the Server to change the transaction logfile size during a download
- Older versions of the DCConnect Server will work properly with the
newer DCConnect Client as long as the Client does not attempt to send
transactions that are longer than the previous maximum
- Transaction Connection specific enhancements:
- Increased maximum number of subroutines and StartMatch scripts
allowed. You can now have over 6000 StartMatch and subroutine scripts
combined.
- Fixed problem in trace output where messages logged by the
set-terminal-UV thread would use/affect the elapsed time shown for
commands being executed in the current script.
- The Submit_Validation command now supports an optional third
parameter 'DONT_LOAD' which specifies that the file be created but
should not yet be loaded to any terminal.
- New Capture_Screen command can be used to write to a large user
variable, the entire contents of the current emulator screen. The
parameters are the target user variable and an optional error label.
- New Load_Term command can be used to tell the DCConnect Server to
download all or some of the files to a data collection terminal.
- Added support for new data part: CURRENT_MAILBOX and the
Write_Xact command now supports the use of any data part for the
optional timestamp and/or optional mailbox list.
- The Delay command now supports the keyword "key" in place of a
numeric value. If 'key' is used, a "Press OK to continue" popup is
shown.
- DCConnect Server specific enhancements:
- Replaced use of DAE/CS2 for internal messaging infrastructure with
implementation using Windows named pipes.
- Added the ability to change the default number of retries that the
server does for each command sent to a terminal. The default is 3 but
that can be changed by creating a file called \dcconn\data\dcxpo.ini
and including in it a line similar to the following: CMD_RETRY = 5.
|
October 2005 |
DCConnect Client version 2.20 now available
for entitled customers
This addresses the following issues (plus some other more minor issues)
since version 2.10B
|
September 2005 |
Please See an
Important Note About a Change in the Way DCConnect Fixpacks are
Obtained |
October 2004 |
Updated Fixpack F available
for (Windows NT/2000/XP) products on the DCConnect 1.4.0 CDs and the IBM
Data Collection 2.0.0 or 2.0.1 CDs.
The original Fixpack F was missing ADPTUTIL.DLL which is required when
using Transaction Connection with any XML_??? commands. |
October 2004 |
DCConnect Client version 2.10B now available
This addresses the following issues from version 2.10A
- Added ability to view parameters on the VIEW USER VARS screen.
- Fixed misalignment exception on Windows CE devices with certain
processors.
- For Symbol Spectrum 24 terminals (e.g. PTD6840, VRC6940, WSS1040)
had to remove support for allowing a hostname to be provided for the
TCPIP_HOST keyword and the -h command line parameter. With this support
included, the resulting executable for the DCConnect Client was too
large to run properly.
|
September 2004 |
Fixpack F available
for (Windows NT/2000/XP) products on the DCConnect 1.4.0 CDs and the IBM
Data Collection 2.0.0 or 2.0.1 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection and the DCConnect Transaction
Building Tool (aka DCTPB).
This fix pack brings these products up to the same level as version
2.1.0 of the IBM Data Collection CD.
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
See the fix pack readme
for all the details. |
September 2004 |
DCConnect Client version 2.10A now
available
In addition to miscellaneous fixes, the following enhancements have
been made since version 2.OOB was released in August 2002:
- (2.OOC) Fixed problem handling a 'Get User Variable' request from
the DCConnect Server by non-DOS versions of the Client.
- (2.00D) Added TSR_INTERRUPT keyword in EMULATOR.INI and the ability
to change the interrupt that is used by the Client and the TSR for the
various DOS devices that use TSRs (e.g.Intermec 6400, PSC Falcon, Symbol
68xx)
- (2.00D) Win CE only: Fixed problem where screen font would change
after a certain period of usage - usually a day or two.
- (2.00E) Added support for the POWER_OFF_TIMER keyword for PSC/Percon
Falcon and LXE MX2 terminals by enhancing falc_tsr.exe.
- (2.00E) Support for Windows CE devices with ARM/XScale processor,
Windows CE 3.0 but on which Pocket PC is not installed
- (2.00F) New EMULATOR.INI keyword UV_POOL_SIZE which allows you to
specify the amount of memory that should be used to hold user variable
data (global, local, parameters). In the past each of the 100 global
user variables was allocated a 128 byte buffer regardless. With the
implementation of a single memory pool for variables/parameters, the
only limit to the size of a variable/parameter is the size of the pool
(provided all other variables are empty). One other caveat: for every
level of subroutine that is entered, a structure is added to the pool in
order to keep track of the local variables and parameters and return
point for that subroutine. Default size is 10000 bytes if this keyword
is not used. Although variables can grow to the pool size within the
terminal, the amount that can be exchanged with the Server (via the API
calls DcxSetTermUserVariable/DcxSetNTermUserVariables and
DcxGetTermUserVariable) is limited. With version 2.1.0 of the Client and
Server that limit was increased from 118 bytes up to 975 bytes.
- (2.00G) New EMULATOR.INI keywords ABORT_READ_ON_RS232_INPUT and
ABORT_ONKEY_ON_RS232_INPUT which allow a terminal to be set up to
simultaneously handle an RS-232 initiated transaction program and
user-initiated transaction programs that wait indefinitely for user
input.
- (2.10) All the features
added to DCTPB 2.10 (except named user variables - which applies
only to DCTPB)
- (2.10) Support added for the Intermec CK30 and CV60 terminals
- (2.10) Support added for the Symbol MC 90xx terminals
- (2.10) The -h command line parameter and the TCPIP_HOST keyword in
EMULATOR.INI can now handle a hostname instead of just an IP address for
the location of the DCConnect Server. A colon may also be now used
instead of the comma preceding the optional port number that follows the
hostname/IP address.
- (2.10) The FULL_SCREEN keyword can now be used on any Windows CE
device to hide the start button and tool bar - provided greater use of
the screen by the Client
- (2.10) New EMULATOR.INI keyword, HIDE_MENU_BAR, available for
Windows CE devices to hide the DCConnect menu bar that includes the
File/Diagnostics/About pull-downs. When in effect, use the Home/?/= keys
to bring up the DCConnect Client menus - in the same manner that is done
for DOS and Windows flavors of the Client.
For all the details, see the fix
pack README
For more information about the new features mentioned above, see the DCConnect
Client User's Guide online. |
September 2004 |
Terminal Services for DOS/Windows 2.10 now
available
The latest features include:
- Support for Windows CE devices including Intermec 600, 700,
Intelligent Instrumentation LanPoint CE and Symbol 81xx.
- Dynamically configuration of DWTS terminals; they do not have to be
preconfigued in the DCConnect Server configuration.
- Support for user variable data up to 975 bytes in length.
- New API DwsQueryTransactionCnt for determining the number of
transactions stored locally on the device.
- Support for multiple simultaneous calls to the API
DwsGetUserVariable.
For all the details, see the fix
pack README |
September 2002 |
OS/2 version of Fixpack E now
available for products on the DCConnect 1.4.0 CDs. (NT/2000
version of Fixpack E became available in June 2002).
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection and the DCConnect Transaction
Building Tool (aka DCTPB). Prior to fix pack E, fixes for DCTPB were in a
separate fix pack.
See the June
2002 entry below for a list of key enhancements and fixes. (Some, such
as ODBC support in Transaction Connection, do not apply to OS/2).
See the fix pack readme
for all the details. |
August 2002 |
DCConnect Client version 2.00B now
available
In addition to miscellaneous fixes, the following enhancements have
been made since version 1.41B was released in March 2001:
- (1.41C) Added support for RS-232 initiated transactions (transaction
ID 55)
- (1.41D) Added support for POWER_OFF_TIMER keyword when using
Intermec 6400 terminals.
- (1.41D) Several enhancements for Windows CE flavors of the Client
- Added support for the LanPoint CE from Intelligent Instrumentation
- Font now adjusts based on NUM_ROWS and NUM_COLS keywords
- Extended keys now work (arrows, home, F1-F10, insert delete)
- Arrow keys now scroll the screen contents when dimensions are less
than 20x40
- Serial port can now be used to talk to attached devices such as a
serial printer
- DUMP MEMORY and TRACE LOG now work when going to COM1
- Improvements in performance for screen updates
- Cursor positioning and size improved
- (1.41D) The DUMP MEMORY and TRACE LOG options now work for 32-bit
Windows flavor of the Client
- (1.41D) The CFR SenRead() call now returns the bar code type for
Antares terminals
- (1.41D) Multiple instances of the 32-bit Windows and Windows CE
flavors of the Client can now be run from the same directory - provided
that the TCP/IP port number is specified on the command line using the
-P option. This enabled the use of the Client in a Citrix environment.
- (1.41E) Decoded scanner input can now be read directly from the
serial port if the keyword USE_RS232_FOR_SCANNER is used in
EMULATOR.INI.
- (1.41F) Added TIMEZONE_ADJUST keyword for EMULATOR.INI so that the
Client can make adjustments to the time based on the time zone even when
it does not have the permission to actually change the clock on the
device/PC. (Sometimes needed in the Citrix environment).
- (1.41G) Added support for use of the environment variable DCCLIENT
to specify where DCConnect Client files should be found (e.g.
EMULATOR.INI, ETSCHECK.LIC) and created (e.g. LOGFILE.LOG, downloaded
CFRs for Windows flavors). For Windows CE, where the concept of
environment variables does not exist, the following registry value can
be set instead: HKEY_LOCAL_MACHINE\SOFTWARE\IBM\DCConnect Client\path
- (1.41G) For Windows CE flavors of the Client, support was added for
the keyword SELECT_FONT so that you can control which mono-spaced font
is used by the Client.
- (1.41G) For Windows CE flavors of the Client, added the Diagnostics
pull-down along with the submenus for Trace Logfile, Dump Memory, Start
Stepping and View User Variables. Also added support for reverse video.
- (1.41G) Added support for MENU_PASSWORD keyword in EMULATOR.INI
which, when used, requires the user to enter a password to get to all
menu options except VERSION INFO and TXTN COUNT.
- (1.41G) Windows CE only: added support for MENU_ITEM keyword to add
new options to a new 'User' pull-down. These menu items are tied to
user-created functions in a DLL, ETSUSER.DLL.
- (1.41G) Windows CE devices that the Client has been used on include:
- Handheld Products "Dolphin" 7400
- Intermec 600
- Intermec 700
- Intermec 5020
- Intermec 6651
- Intelligent Instrumentation LANPoint CE
- Symbol PDT 81xx
- Pocket PC Emulation environment
- (1.41H) Batch versions of the Client that are doing dial-up will now
wait up to 10 seconds to see if the line is already connected to the
DCConnect Server before dialing. This allows the same terminal to
connect to the Server from a dedicated serial line or a dial-up line.
- (1.41H) Windows CE only: Added FULL_SCREEN keyword to EMULATOR.INI
so that on Pocket PC devices the user can be prevented from doing
anything with any other application on the terminal while the Client is
running.
- (1.41H) Scanner is now turned on when the Client exits so that the
scanner can be tested at the DOS prompt if necessary.
- (1.41I) Added support for the MX1, MX2 and VX1 terminals from LXE.
- (1.41I) PSC/Percon Falcon 345 terminal is also now supported because
it is identical to the LXE MX2.
- (1.41I) Added support for the keywords IGNORE_UNDERLINE (display
attribute) and DONT_CHANGE_SCREEN_SIZE which are both required for
support of the LXE / PSC/Percon terminals.
- (1.41I) Added support for the keyword PF_AUTO_ENTER which tells the
Client to assume an Enter key is pressed after any PF Key is pressed
during a READ command for which PF Key input is allowed.
- (1.41I) The CFR packages (CFRUTL24.ZIP, CFRSMP24.ZIP and
CFRPAN24.ZIP) are now set up to use the environment variable CFRTOOLS to
find .H and .LIB files. Following the method used in these samples, your
CFR source can now be separated from the .H and .LIB files provided with
the product.
- (1.41I) Added support for the keyword USE_TSR_FOR_KEYBOARD in order
to allow the PSC/Percon Falcon 345 / LXE MX2 terminals to be able to
distinguish between keyboard and scanner input. At this point this
keyword can only be used for these terminals and only if the
falc_tsr.exe is loaded before the Client is started.
- (1.41I) Windows CE only: the MENU_ITEM keyword now allows an
optional password parameter.
- (2.00) Version bumped up to 2.00 for release of new CDs in June
2002.
- (2.00) Added support for the keyword MENU_KEY to override the use of
?, = or Home for bringing up the Client menus.
- (2.00) Windows CE only: starting a second instance of the Client now
brings the first copy to the foreground before the second instance ends
itself.
- (2.00B) Length of phone number for modem dial-up can now be 120
characters.
- (2.00B) Improvements in use of MAKEHEX.BAT and LOADTERM.BAT (used
with Symbol Spectrum 24 terminals) so that images can be easily created
and loaded for more than one model of these terminals.
For all the details, see the fix
pack README
For more information about the new features mentioned above, see the DCConnect
Client User's Guide online. |
June 2002 |
Fixpack E available
for products on the DCConnect 1.4.0 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection and the DCConnect Transaction
Building Tool (aka DCTPB). Prior to fix pack E, fixes for DCTPB were in a
separate fix pack.
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
- DCConnect Server/User Interface enhancements:
- The server now keeps track of every type of download request on
disk so that they are not lost if the server is shutdown and
restarted.
- The download of the validation mapping file to the terminal would
sometimes include both upper and lower case versions of the same name.
This could cause validation to fail in the terminal.
- The DCConnect Server now filters out the logging of the message
"DCR0276E: Error reading from TCP/IP socket; TCP/IP error = 10054"
only in the case that the error is 10054 (which means 'connection
reset').
- In the DCConnect User Interface the Terminal notebook pages have
been reorganzed to change the Miscellaneous tab to a Time tab. The
fast clocking page is now the last one on the Time tab and the Sensor
Badge Length page is now the first on the Devices tab.
- Added to DCConnect the ability to specify which time zone
terminals are in relative to the Server. A new Time Zone page (3 on
the Time tab) in all the different Terminal Settings notebooks,
including DWTS, lets you specify how many hours before or after the
Server the terminal is. Whenever the Server has to set the time for a
terminal, it adjusts the outgoing set time command by the specified
number of hours. However, the Server does not adjust the timestamp of
incoming transactions; transactions received will reflect the time
zone of the terminal from which they originated.
- In most cases in the DCConnect User Interface, when an item is
linked to the mouse pointer and is then successfully dropped on to a
target, it no longer remains linked to the mouse pointer. Therefore
you no longer have to click on the Arrow button to clear the mouse
pointer.
- The DCConnect User Interface will now warn about changes not being
saved in the following two new situations: when the DCConnect Server
is started started and whenever a terminal download is started.
- In the User Interface references to 7524 Terminals are now
'7524/Client'. References to DOS terminals are now DWTS. References to
"TCP/IP DOS" changed to "TCP/IP DWTS"
- Added the Time Formats page to the 7524/Client notebook since the
DCConnect Client now supports showing the idle date and/or time.
- Support added for up to 8 COMx lines. Maximum used to be 4.
- In the User Interface, found more instances where validation file
names, CFR names and graphics file names were being handled case
sensitively. This could cause odd behavior such as the UI not acting
on a request to download just a CFR to a terminal.
- Found that there were several User Interface notebooks which would
not keep track when changes were made (OK button pressed) and thus if
the UI were closed without saving those changes, no warning was given.
- The DCConnect Server serial port driver will now close and reopen
the serial port if there is nothing received on the port during a
period of time that is the slow poll rate times 5. This was done to
better handle connections via modems and the Lantronix network-serial
device.
- Another attempt to fix the time zone problem that should have been
fixed in fix pack D. This time the use of the failing compiler
function was replaced by an operating system-specific call to get the
date and time.
- Transaction Connection enhancements:
- Now includes support for ODBC connections to databases.
- New feature added to allow passing of parameters to subroutines
using new alternatives to CallSubroutine and StartSubroutine: Call and
Sub.
- If and While commands can now be written more naturally, without
the need for all the extra commas and zeros.
- New feature allows the declaration of local variables in Start...
scripts and subroutines using the new script command Declare.
- New feature makes it easier to build up a user variable composed
of other user variables and constants. The new scripts commands
Begin_UV and End_UV are used to accomplish this.
- Corrected problem with Set_UV_File_Data() command. It was acting
like Append_UV_File_Data - not clearing the UV first.
- Reworked the showing of user variables in a trace to limit those
shown to only be ones that apply to the current command.
- Added new Dump_UVs() command so that the entire set of non-empty
user variables, global and local, can be dumped do the trace file at
any point in the script.
- Added XML_Parse command to allow parsing of an XML message from
any source (database, file, etc.). The returned handle can be used in
any other XML command to manipulate the message.
- Fixed problem where the 121st subroutine encountered in the script
would not have any of its commands performed. This would occur only
when the first subroutine was defined before any StartMatch, StartKey,
StartVal, StartTime and StartFunctionGroup/StartCluster command.
- DCTPB enhancements:
- Other enhancements:
- Created a Microsoft Visual Basic sample application that
demonstrates how to call DCConnect C APIs from VB. This application
shows the real-time status of the DCConnect Server using the
'blue-man' icons and it lets you list all terminals or all mailboxes
and their current status.
- In VBDCX.DLL, the DLL needed by Visual Basic applications in order
to call DCConnect APIs, added an alternative to
vbDcxSetNTermUserVariables called vbDcxSetNTermUserVariables2.
See the fix pack readme
for all the details. |
March 2001 |
DCConnect Client version 1.41B now
available
In addition to miscellaneous fixes, the following enhancements have
been made since version 1.40M was released in May 2000:
- (1.40N) Added support for CFR API KbdHandleArrowKeys which allows
the CFR to turn on and off the Client's handling of the arrow keys to
scroll the window.
- (1.40N) Found that several CFR APIs were missing from the 32-bit
Windows and Windows CE versions of the Client. These were:
QueryTransactionCnt, SendTransaction, AliasTransID, GetTerminalAddress,
GetPowerState, and KbdGetShift.
- (1.40O) For Symbol Spectrum 24 terminals, added use of a TSR which
provides support of the serial port as well as the ability for the
Client to be able to distinguish between keyboard and scanner input.
- (1.40P) The CFR API ClearUserVariable can now be used to clear the
transaction buffer by passing -1 or TRANS_BUFFER for the user variable
number.
- (1.40Q) Fixed memory fragmentation problem that would cause
downloads to fail with insufficient space error even when the total
available space was sufficient.
- (1.40R) The SHOW_IDLE_TIME keyword in EMULATOR.INI now takes
additional parameters which allow you to specify the format of the date
and time. To go along with this, support was added for new keywords that
can specify the DATE_SEPARATOR and TIME_SEPARATOR.
- (1.40S) Added support for keyword IGNORE_ARROW_KEYS in EMULATOR.INI
- similar in function to the CFR API KbdHandleArrowKeys, added in
version 1.40N.
- (1.40T) A new DIAGNOSTICS menu was added to the MAIN MENU and the
options TRACE LOG and DUMP MEMORY were moved to the new menu.
- (1.40T) A new option was added to the DIAGNOSTICS menu, allowing you
to VIEW USER VAR contents.
- (1.40T) A new option was added to the DIAGNOSTICS menu, allowing you
to START STEPPING through a transaction program. When active, the status
row of the terminal will display the next command to be executed. You
must press Enter to move to the next step or Esc to cancel stepping.
- (1.40T) Added two new keywords to EMULATOR.INI, FILE_PAGING and
LOCK_IN_MEMORY. FILE_PAGING tells the Client to store certain downloaded
files on disk rather than in memory - until those files are actually
needed by the operations of the terminal user. This allows the Client to
handle much larger downloads on terminals which have limited RAM memory,
such as the Antares. The LOCK_IN_MEMORY keyword is used to specify
validation files that must remain in memory at all times. Note: In order
to use this feature, you must install fix pack D for DCConnect/TC.
- (1.40T) For Symbol Spectrum24 terminals, the self-extracting zip
file, FLSHBLD.EXE, was updated for support of the latest Symbol flash
drivers.
- (1.40T) New keyword KEY_CLICK added to EMULATOR.INI to allow the
Symbol Spectrum24 terminal to give a click when keys are pressed.
- (1.40U) Fixed problem with Validation() API in CFR: it was failing
to find a remote validation file name when that name was at the end of
the list of valid file names (file E).
- (1.40U) Fixed problem enforcing the maximum length of a validation
request. Before this fix, if the data was too long, memory corruption
occurred.
- (1.40V) The CFR API GetTerminalAddress() now returns the proper IP
address for the Windows versions of the Client.
- (1.40V) Fixed problem with CFR API Validation() that resulted in a
malformed transaction when more than 6 validation files were in use.
- (1.40V) The 32-bit Windows version of the Client now more smoothly
handles running with different screen sizes (as specified by the
NUM_ROWS, NUM_COLS or DEVICE keyword or the -d command line parameter).
- (1.40W) Fixed problem which prevented the reading of transactions
from the logfile on startup in the case that the MAX_TRANSACTIONS
keyword was being used.
- (1.40X) For Symbol Spectrum24 terminals, support was added for a new
keyword, POWER_OFF_TIMER.
- (1.40Y) The DUMP MEMORY option of the DIAGNOSTICS MENU now properly
handles file 0 (transaction program file) even when FILE_PAGING is in
effect.
- (1.40Y) Fixed problem on Antares terminals which did not allow the
output of the TRACE LOG and DUMP MEMORY options to be sent to the serial
port.
- (1.40Y) New CFR API GetTerminalSettings added. It fills in the
contents of a TERM_SETTINGS structure, which currently includes the
number of rows and number of columns that the Client has been configured
to use.
- (1.40Z) Fixed problem, introduced in version 1.40T, that caused a
branch larger than 64K bytes to go to the wrong place in the transaction
program file.
- (1.41A) Fixed the cause of a stack overflow error when using any of
the ComXXX() CFR API calls on an Antares terminal.
- (1.41A) The menu options TRACE LOG and DUMP MEMORY now work properly
to the RS-232 port for terminals that use a TSR for serial port support
(Telxon and Symbol Spectrum 24).
- (1.41B) The menu options DUMP MEMORY and VIEW USER VAR were both
improperly showing characters with hex values greater than or equal to
0x80.
- (1.41B) Fixed problem running 32-bit Windows version of Client on
Windows 95/98.
For all the details, see the fix
pack README
For more information about the new features mentioned above, see the DCConnect
Client User's Guide online. |
March 2001 |
Fixpack D available
for products on the DCConnect 1.4.0 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection. Fixes/changes are provided
for the following key areas plus other minor ones not mentioned here:
- Fix for problem updating time in certain non-US locations at the
start of daylight savings time.
- Fix for support of downloading files greater than 99999 bytes in
size.
- Addition of VBDCX.DLL for Windows NT which allows Microsoft Visual
Basic applications to call DCConnect APIs.
- In Transaction Connection, the data parts SESSION_STATUS, XACT_AGE
and LAST_ERROR were mistakenly considered invalid when running in Data
Request mode.
- Fixed a couple causes of access violations in Transaction
Connection.
- In Transaction Connection added support of BIGINT and REAL database
types.
- The processing of StartTime scripts by Transaction Connection will
now detected a time change, such as the start of Daylight Savings Time,
within 5 seconds.
- Increase the number of allowed subroutines from 125 to 250 in
Transaction Connection.
- Added utility IMBEDSCR.EXE for creating a single listing file for a
top-level Transaction Connection script and all imbedded files. This
tool can also be used with DCTPB scripts.
See the fix pack readme
for all the details. |
March 2001 |
Fixpack D available
for the DCConnect Transaction Building Tool Release 2.0 (32-bit
DCTPB).
Fixes/changes are provided for the following key areas plus other minor
ones not mentioned here:
- Fixed problem ignoring tabs between an ending double quote and a
comma that is the delimiter before the next parameter.
- Inline messages and messages from MESSAGE commands can now be used
at the same time. The message numbers in MESSAGE commands no longer need
to be sequential either, although that is recommended.
- The APNDSTR command now accepts 0 for the length, indicating that
the exact length of the text should be used.
- Added utility IMBEDSCR.EXE for creating a single listing file for a
top-level script and all imbedded files. This tool can also be used with
Transaction Connection scripts.
- The maximum number of keys allowed for an ONKEY or ONSUB command is
now 50.
- Comments starting with double slash (//) are no longer automatically
included in the .PGM file during compile unless the new command line
parameter, INCLUDE_COMMENTS, is used.
See the fix pack readme
for all the details.
|
October 2000 |
7524
ETS / DCConnect Client Technical Reference now available online
This manual is the equivalent to the 7526 Programming Technical
Reference, but it is for terminals loaded with 7524 ETS flash and
terminals running the DCConnect Client.
It covers the details of the file formats in the terminal and syntax of
the commands that go back and forth between the terminal and the DCConnect
Server. This can be useful for interpreting the output of a Line Trace
(from LINETRAC.EXE) and for interpreting the raw format of transaction
program commands as they are downloaded to the terminal. The latter will
be useful for the soon-to-be-released feature in the DCConnect Client that
will allow you to step through transaction programs one command at a time.
This manual also covers all of the CFR APIs available for 7524
terminals and terminals running the DCConnect Client. |
June 2000 |
Borland Turbo C++ 3.0 for DOS compiler is now supported for
building CFRs
The latest 7526
CFR Toolkit now includes both the Borland and IBM C/2 versions of
CFRAPI26.LIB for building CFRs for 7526 terminals.
The latest 7524
CFR Toolkit and DCConnect
Client Toolkit now include both the Borland and IBM C/2 versions of
CFRAPI24.LIB for building CFRs for 7524 terminals and terminals running
DOS versions of the DCConnect Client (formerly 752x Emulator for DOS).
|
June 2000 |
Sample CFR packages have been updated to include support of the
Borland Turbo C++ 3.0 for DOS compiler as well as support of Windows
platforms.
Three different packages are available for each terminal type/platform:
- A utility library of useful routines to include in your CFR.
Separate packages are available for 7526
terminals, for 7524
terminals, and for devices
running the DCConnect Client.
- A sample CFR including many common functions that add more power and
flexibility to your transaction programs. Separate packages are
available for 7526
terminals, for 7524
terminals, and for devices
running the DCConnect Client.
- Input panel driver CFR which provides several functions for
enhancing the display and input capabilities of your transaction
programs. Functions include pop-ups, pre-filled fields and more.
Separate packages are available for 7526
terminals, for 7524
terminals, and for devices
running the DCConnect Client.
Some pacakges may require other packages if the executables have to be
rebuilt.
The packages have also been renamed for clarity. Here is a chart of the
old and new names:
New Name Old Name Description
-------- -------- -----------
CFRUTL26.ZIP Part of CFR26_30.ZIP Library of utility functions for
7526 terminals.
CFRSMP26.ZIP Part of CFR26_30.ZIP Sample CFR for 7526 terminals
CFRPAN26.ZIP Part of CFR26_30.ZIP Input Panel Driver CFR for 7526
terminals.
CFRUTL24.ZIP CFR24LIB.ZIP Library of utility functions for
(32-bit Windows 7524 terminals and devices running
version used to be the DCConnect Client.
in CFRBLD32.ZIP and
Windows CE version
used to be in
CFRBLDCE.ZIP).
CFRSMP24.ZIP Part of CFR24.ZIP Sample CFR for 7524 terminals and
devices running the DCConnect Client
CFRPAN24.ZIP Part of CFR24.ZIP Input Panel Driver CFR for 7524
terminals and devices running the
DCConnect Client.
Because both 7524 terminals and the DCConnect Client support the same
CFR functions, the three 7524 packages listed above include all files for
building not only 7524 CFRs but also for building DCConnect Client CFRs on
both DOS devices and Windows devices. |
May 2000 |
Additional support for terminals
from Intermec, Symbol and Telxon in version 1.40m of the DCConnect
Client (formerly called 752x Emulator for DOS). Newly supported
terminals include:
- Intermec 5020 with Windows CE
- Intermec 6400
- Intermec Trakker Antares 241x, 242x, 245x, 246x, 248x
- Symbol FMT3000
- Telxon 870IM
In addition, versions of the DCConnect Client can run on Windows
95/98/NT/2000 PCs - appearing like any other third-party terminal to
the DCConnect Server. In fact, the DCConnect Client can run on the same PC
as the DCConnect Server - which is a great way to test terminal
applications - especially when you don't yet have the hardware.
The Third-Party
terminal page now provides information about how to get the 7526-MTC
terminal.
The latest fix
pack is available to provide support for all of these new terminals.
In addition to miscellaneous fixes, the following enhancements have been
made since version 1.40c was released in October 1999:
- (1.40E) Added support for serial port in all supported Telxon models
- (1.40F) Arrow keys can now be used to scroll screen if physical
viewport is less than 20x40
- (1.40F) All configuration can now be done using EMULATOR.INI. The
following keywords were added:
- NUM_ROWS
- NUM_COLS or NUM_COLUMNS
- STATUS_ROW
- MSG_BUFFER_FULL
- MSG_WAITING_FOR_FILES
- TCPIP_PORT
- TCPIP_HOST
- RESEND_TIMER
- ADDRESS
- BAUD_RATE
- COM_PORT
- DEVICE
- (1.40H) To save space, all configuration screens were removed from
the menus. Instead a new VIEW SETTINGS option was added so that you can
verify EMULATOR.INI was set up properly.
- (1.40J) Can now handle transaction program file > 99999 bytes
- (1.40J) Now handle a date rollover problem that DOS has if a request
to get the date/time is being made precisely at midnight.
For all the details, see the fix
pack README
For complete information about configuring the DCConnect Client and
setting up all the different third-party terminals, see the DCConnect
Client User's Guide online. |
April 2000 |
Fixpack C available
for products on the DCConnect 1.4.0 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection. Fixes/changes are provided
for the following key areas plus other minor ones not mentioned here:
- Support added for Intermec Trakker Antares terminals
- Fix for APAR PQ35298: problems after starting the Server when it was
already running
- Fix for APAR PQ36218: User Interface not refreshing because the Node
name started with a number rather than a letter.
- Support for more control characters added for the
Set/Append_Kbd_UV_Data command in Transaction Connection scripts.
- Change in Transaction Connection's automatic recovery logic for a
-911 Timeout/Rollback error
- Fix in the backup/restore utility for handling long file names that
happen to be in the directories being backed up.
- The Server can now handle downloading of Transaction Program files
of 100,000 bytes or more.
See the fix pack readme
for all the details. |
March 2000 |
DCConnect Products Have been tested with Windows 2000
We found no problems installing and running the DCConnect family of
products on Windows 2000. We installed DCConnect Server, Toolkit,
Transaction Connection, 7524 Interface Support and ERPBridge for J.D.
Edwards One World, Shop Floor Control transactions. Processing of Shop
Floor Control transactions, which involves interactions with DB2 and
Personal Communications to the AS/400, worked properly. Testing involved
terminals attached via the serial port, Ethernet, Norand RF and an ARTIC
adapter. |
November 1999 |
Year 2000 Problems Found and Fixed in Transaction Connection
For all versions of Transaction Connection starting with the one on the
DCConnect -02 CD, problems with the date have been found in the following
functions:
- Using the data part CURRENT_YEAR
- Using the data part CURRENT_DATE
- The command Write_Xact would have an invalid date put into the
transaction if a date was not explicitly specified as the last optional
parameter. As a result the call to DCConnect would fail with a -506
return code indicating an invalid date or time.
- Trace data on the screen and in the trace file
In all cases, the value for the year used to show up as 100 for the
year 2000, 101 for the year 2001, and so on.
In addition, the following date-related problems, not specific to the
year 2000, were fixed for the Xact_Age command, the first of these existed
in all versions of Transaction Connection:
- If the transaction had a date from the end of a year but it arrived
in TC the next year, the Xact_Age calculation would be incorrect
resulting in the transaction never being considered too old.
- During any leap year the Xact_Age function would always report that
the transaction was too old.
So who is affected by these problems?
- All installations of ERPBridge for J.D. Edwards use the Xact_Age,
Write_Xact functions which have Year 2000 problems. The fixes must
therefore be applied for these installations.
- The TC scripts shipped by IBM for ERPBridge for MAPICS do not
include any of the TC functions that have Year 2000 problems except for
the displaying of the date in screen and trace data - which is purely a
cosmetic problem for all TC installations. If the scripts have been
customized in any way, you need to examine the scripts to find out if
any of the above mentioned functions have been added.
- For any other use of TC, you will have to examine the scripts to
determine whether or not any of the functions are being used which have
Year 2000 problems.
- If you are not sure whether or not any of these functions are being
used, then it is best to install the fixes anyway.
Fixes for these problems are available for two versions of Transaction
Connection and each is available on both OS/2 and Windows NT:
|
November 1999 |
Fixpack B available
for products on the DCConnect 1.4.0 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection. Fixes/changes are provided
for the following key areas plus other minor ones not mentioned here:
- Year 2000 fixes for Transaction Connection
- Slow down in polling of terminals on serial and ARTIC lines
- Inablity to download 7527 ETS to 7527 terminals.
- PTF for the transaction program binding problem on Windows/NT is
included in this fix pack
- The LINETRAC.EXE utility has been enhanced to allow the use of
circular logfiles so that tracing can run forever without consuming all
disk space.
See the fix pack readme
for all the details. |
October 1999 |
PTF for 1.4.0 Transaction Program Binding problem on Windows/NT is
now available
to apply on top of Fix Pack A for the 1.4.0 CDs. |
October 1999 |
Version 1.40c of 752x Emulator for DOS is now
available.
Although the jump in version numbers from 1.21a to 1.40c seems large,
there were not very many changes made between versions. We wanted to bring
the version numbers of all of our products in line. In fact, the contents
of the 1.4.0 CD for the 752x Emulator for DOS is equivalent to the 1.21a
version. There are 6 minor fixes since the CD that are in the 1.40c
version.
For all the details, see the fix
pack README |
September 1999 |
New set of DCConnect/ERPBridge CDs replaces products from the
all-in-one DCConnect -03 CD.
The announcement
has all the details. But here are the highlights along with other
important notes:
- 6 products on CD:
- 41L2179 DCConnect Server for OS/2 and Windows/NT ($2995)
- 41L2160 DCConnect Development Toolkit for OS/2 and Windows/NT
($3495)
- 41L2209 DCConnect Transaction Connection for OS/2 and Windows/NT
($3000)
- 41L2203 DCConnect Transaction Building Tool for OS/2 and
Windows/NT ($2000)
- 41L2166 ERPBridge for MAPICS for OS/2 and Windows/NT ($3500)
- 41L2189 DCConnect 752x Emulator for DOS ($350 per device)
- 1 product on diskette:
- 41L2197 DCConnect Terminal Services for DOS and Windows ($395 per
machine)
- Where relevant, both the OS/2 and Windows/NT versions of the product
are on the same CD. So users can choose to install on either operating
system when they purchase the one product.
- All products have been bumped up to Version 1 Release 4 Modification
level 0 to simplify things - including the 752x Emulator for DOS. (The
7524 RF/Batch flashes are going to this level too).
- The DCConnect Server no longer has 3 tiers of pricing; there is just
one price for support of the maximum number of terminals.
- Upgrade pricing is available at 70% off for customers of record of
the previous DCConnect products.
- The upgrade pricing is also available to the 1.4.0 versions of the
DCConnect Server and the DCConnect Toolkit for customers of record of
DCC/2 (5756-144).
- All future fix packs will be built based from the 1.4.0 levels of
code on the new CDS. So it will be necessary for existing customers to
upgrade to the 1.4.0 CDs for all products in order to get any future
enhancements, features or fixes.
- When you upgrade any one of the following: Server, Toolkit,
Transaction Connection or ERPBridge for MAPICS, you must also upgrade
all of the others of these products which you already have installed.
This is because they are all built using the latest Visual Age compiler
libraries and DLLs which won't co-exist with programs using the older
version of these libraries/DLLs.
- The JD Edwards products are being rereleased on separate CDs later
in September - including support for One World. Stay tuned.
- 7524 Interface Support was not released on its own CD; it is still
available on the -03 CD as the same product number (5696-977) with the
same choices of tiered pricing. The 1.4.0 version of the DCConnect
Server was set up to include all the latest files needed for 7524 IS
except for the tier-enforcing DLL that comes on the CD. Therefore
installing 7524 IS from the -03 CD after installing the 1.4.0 Server
will still work properly.
These CDs actually became available on August 13. However, the content
of this website was frozen until mid-September.
Due to a regression bug found after the content of the 1.4.0 CDs was
frozen, it is recommended that fix pack A for the 1.4.0 CDs be applied
after upgrading to/installing the new CDs. See the next bullet for more
details. |
September 1999 |
Fixpack A available
for products on the DCConnect 1.4.0 CDs.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection.
The 1.4.0 CDs included a couple of regression bugs that resulted from
building with the latest compiler version. This fix pack provides a fix
and partial fix for these problems.
See the fix pack readme
for all the details.
|
September 1999 |
Flash level 1.40c available
for all RF and batch models of IBM 7524 (Intermec/Norand 11xx/17xx/59xx
terminals).
Although the jump in the version number from 1.21A to 1.40C is large,
there are only a few changes. The version was bumped to 1.40 to bring it
in line with the versions for the new DCConnect CDs.
This version features a fix for the possible loss of
configuration/files when the terminal is powered off and on. Refer to the
README
for this fix pack for the other enhancements/fixes. |
May 1999 |
Additional support for terminals
from Intermec, Symbol and Telxon in version 1.21A of 752x Emulator for
DOS. Newly supported terminals include:
- Intermec 6540 (formerly MaxiLAN DX) and Janus 2050
- Symbol LRT3840, PDT3140, VRC3940, WSS1040 and PDT6840
- Telxon 960SL, 960X and 860IM
The latest fix
pack is available to provide this support. In addition to fixes, the
following enhancements have been made since the February 1998 release of
the product:
- (1.11F) Scanner is now off except when needed
- (1.20B) Added ComRead() CFR API for reading from the serial port
- (1.20D) Support for 99999 bytes of transaction programs (was 65535)
- (1.20E) GetTerminalAddress now returns IP address and port number
- (1.20F) Added new kind of emulator configuration file, EMULATOR.INI,
including initial support for the following keywords:
- NUM_PF_STRINGS
- NUM_TOUCH_STRINGS
- MAX_TRANSACTIONS
- SHOW_IDLE_TIME
- SCAN_SENTINEL_CHARS
- (1.20G) Added support for PF_MAPPING keyword in EMULATOR.INI
- (1.20J) Added support for TOGGLE_BACKLIGHT_CHAR in EMULATOR.INI
(Janus only)
- (1.20J) Emulator now detects when it's been suspended and notifies
DCConnect after it resumes
- (1.20K) Added support for ALL_SCAN_DATA_UPPER_CASE and
ALLOW_LOWER_CASE keywords in EMULATOR.INI
For all the details, see the fix
pack README
For complete information about configuring the emulator and setting up
all the different 3rd party terminals, see the 752x
Emulator For DOS README online. |
May 1999 |
Flash level 1.21A available
for all RF and batch models of IBM 7524 (Intermec/Norand 11xx/17xx/59xx
terminals).
In addition to fixes, the following enhancements have been made since
the 1.11A release:
- (1.11F) Added support for 9.02 OWL Intermec/Norand 'Falcon' devices.
- (1.11F) Scanner is now off except when needed
- (1.20A) Intermec/Norand 17xx models now support 16x31 display size
- (1.20B) Added ComRead() CFR API for reading from the serial port
- (1.21) Added support for new 2.4ghz Proxim radio (supports old one
too)
For all the details, see the fix
pack README |
May 1999 |
Fixpack C available
for Data Collection Transaction Building Tool Release 2.0 (32-bit
DCTPB).
Just a few minor fixes, but the documentation for this product is now
included in the fix pack and it is available
online.
|
April 1999 |
We've moved the ERPBridge/Data Collection web pages to http://www.software.ibm.com/data/dcconnect.
|
March 1999 |
Fixpack D available
for products on the DCConnect -03 CD.
Fixes and new features are provided for the DCConnect User Interface
and Server as well as Transaction Connection.
See the fix pack readme
for more details.
|