Install the eProcess 5.0 Connectivity Bundle for FileNet Open Client
The instructions in this document are for use with FileNet Open Client versions 3.3 and 4.0.
Use the following procedure to install the eProcess Connectivity Bundle on your web server.
Requirements
The following software must be installed on the web server prior to installing the eProcess Connectivity
Bundle.
- The appropriate version of FileNet Web Services: 3.3 or 4.0. See the FileNet Web Services Administrator's Guide for instructions.
- The appropriate version of Open Client with eProcess 5.0 Integration: 3.3 or 4.0. See Install Open Client with eProcess 5.0 Integration.
TIP These instructions assume that you install the software at the default
locations. If you install at custom locations, please adjust these instructions accordingly.
NOTE If you are installing the eProcess Connectivity Bundle on a web server
where VWService has been running, you must uninstall both IDM and the Open Client software before you
reinstall. In addition, use the Administrative Tools to stop the VWService and delete the pwbin
(/FileNet/idm/pwbin) directory and the files it contains.
Install the JRE and the Process Connectivity Bundle software
- Install the Java Runtime Environment (JRE) 1.3.1.
- On the FileNet Web WorkFlo and Toolkit 5.0.0a CD, locate the JRE 1.3.1 installation file
in the downloads directory and copy it to a temporary location
on the web server.
- Run the JRE installation.
- Copy the following files from the Filenet Web WorkFlo and Toolkit 5.0.0a CD:
- Copy the contents of the Open Client Connectivity folder
on the CD to the location on the web server where FileNet Open Client software is installed. The
default location is c:\FileNet\idm\web\fnopenclient.....
(TIP Copy the contents of the FileNet
folder on the CD and paste it into the FileNet folder on the
web server.)
- Copy the j2re-1_4_0-win-i.exe from the Setup
folder on the CD to
c:\FileNet\idm\web\fnopenclient\eprocess\download.
- From the FileNet CSS FTP site, download and install the latest eProcess 5.0.0 Open Client patch, eprocess500-openclient-x.exe. A valid FileNet username and password are required.
ftp://ftp.css.filenet.com/pub/archives/hot_downloads/hotfixes
Unzip the downloaded file and copy the FileNet folder in the patch to the location where the FileNet Open Client software is installed —
\FileNet\...
- Download and install the latest Jiglue patch from the CSS site.
Register the components and start the eProcess Services
- At a command prompt, navigate to the \FileNet\idm\PWBin directory.
- Enter the following commands:
- regsvr32 vwSvcMMC.dll
- regsvr32 jiglue.dll
- If the JRE and the FileNet software are installed in the default locations, the paths in Process.reg
will probably be correct. If you installed the FileNet software in a different location, locate Process.reg
in the FileNet directory on the web server, and use Notepad or
a similar editor to edit the file.
- Update the instances of the JRE path.
- Update the instances of the Open Client installation path.
- After you have saved the updated Process.reg, double-click
the file to update the web server's registry.
- Run regedit and confirm the ImagePath setting for VWServices. The default path is <drive>:\FILENET\IDM\PWBIN\VWServices.exe.
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\VWServices]
- Start the Panagon eProcess Service on the web server.
- At a command prompt in the PWBin directory, enter
the following command:
vwservices.exe -install
- From the Start menu, select Programs > Administrative Tools >
Services.
- Select Panagon eProcess Services Manager and click Start Service on the
toolbar. Exit the Services dialog.
Reset the execute permissions on the Download directory
Execute permissions must be set to None to allow the JRE to be downloaded to the client computer, if necessary.
- On the web server, right-click My Computer and select Manage.
- Under Internet Information Services, open the Open
Client directory, and the eprocess directory.
- Right-click the Download directory and select Properties.
- On the Directory tab, set Execute Permissions to None.
Start a router and initialize an isolated region
Use the following steps to start the eProcess Services Administrator and to define and start one or
more routers. To complete this procedure, you need to know the name of your workflow server and a valid
administrator name and password (eProcess) you can use to log on.
- On the web server, locate eProcess.msc in the PWBin
folder.
- Right-click the file and create a shortcut, then move the shortcut to your desktop.
- Double-click the shortcut to start the eProcess Services Administrator.
- Open eProcess Services Administrator. Right click Panagon eProcess Router and choose New.
- In the Router properties dialog, enter the following:
For the router name, enter vwrouter, or
any name you like.
For PPM Server, enter the name of your workflow server.
Enter a Process administrator username and password.
Select Automatically started.
For additional information about creating a router, see the online Help for Process
Task Manager.
- When you have finished entering the router properties, select the new router and click Start
on the toolbar to start the router.
- Exit and save the console settings.
Use Process Configuration Console to initialize a corresponding isolated region for each router that
you started.
- On a client workstation, enter the URL for Open Client on the web server. The default is
http://web-server-name/OpenClient
Wait for the FileNet Open Client page to display. This may take several minutes the first time.
- On the Open Client page, select Process.
- On the Tools tab, select Process Configuration Console. At the prompt, log on as an eProcess
administrative user.
- In Process Configuration Console, select the name of the router/isolated region, then choose Initialize
isolated region from the Action menu.
For additional information about initializing an isolated region or security considerations, see
the online Help for Process Configuration Console.
At this point, the installation process is complete and the Process applications are available for
use.
Uninstall the eProcess 5.0 Connectivity Bundle for FileNet Open Client
Use the following steps to uninstall the Process software
- On the web server, in the Control Panel, select Add/Remove Programs.
- In the Add/Remove dialog, select FileNet Open Client, then choose Modify and de-select
Open Client eProcess Integration. This uninstalls the Process Integration for Open Client and
allows the remaining FileNet software to run without it.
NOTE If you also have Process for FileNet Web Services Client
running on this web server and you wish to retain it, stop here. Otherwise, if you have only
Process for FileNet Open Client on this web server, continue with steps 3 through 5 below to disable
the Process software. The software will remain on the web server, but it will not be running.
- Run eProcess.msc to access the eProcess Services Administrator. There should be a shortcut
to eProcess.msc on the desktop.
- Select any running routers and stop them, then delete them.
- Start Administrative Tools > Services. Select Panagon eProcess Services Manager
and stop the service and then set the restart to Manual.