The fix is shipped as file IBM.HHOP951.UI52246
The fix has rework (build) date 2017333 (29 Nov 2017)
The following fixes are prerequisites for this fix:
The following fixes are corequisites for this fix:
These requisites can be downloaded from the Developer for z Systems Recommended Fixes page, if not included as file IBM.HHOP951.<req>.
The following fixes are superseded by this fix:
AI55424 AI56005 AI58968 AI60442 AI60726 AI62050 AI62260 AI68691 AI70698 AI75121 AI80148 AI81833 UI35032 UI37226 UI38196 UI41914 UI42753 UI44927 UI46688Steps required to install the fix:
A sequential data set must be allocated on the z/OS system to receive the fix that you will upload from your workstation. You can do this by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.
//ALLOC EXEC PGM=IEFBR14 //* //UI52246 DD DSN=hlq.IBM.HHOP951.UI52246, // DISP=(NEW,CATLG,DELETE), // DSORG=PS, // RECFM=FB, // LRECL=80, // UNIT=SYSALLDA, //* VOL=SER=volser, //* BLKSIZE=6160, // SPACE=(TRK,(473,90)) //*
Upload the file in binary format from your workstation to the z/OS data set. On a Windows system, you can use FTP from a command prompt to upload the file. In the sample dialog shown below, commands or other information entered by the user are in bold, and the following values are assumed:
User enters: | Values |
---|---|
mvsaddr | TC P/IP address of the z/OS system |
tsouid | Your TSO user ID |
tsopw | Your TSO password |
d: | Your drive containing the fix files |
hlq | High-level qualifier that you used for the data set that you allocated in the job above |
C:\>ftp mvsaddr Connected to mvsaddr. 220-FTPD1 IBM FTP CS %version% at mvsaddr, %time% on %date%. 220 Connection will close if idle for more than 60 minutes. User (mvsaddr:(none)): tsouid 331 Send password please. Password: tsopw 230 tsouid is logged on. Working directory is "tsouid.". ftp> cd .. 250 "" is the working directory name prefix. ftp> cd hlq 250 "hlq." is the working directory name prefix. ftp> binary 200 Representation type is Image ftp> put d:\IBM.HHOP951.UI52246 200 Port request OK. 125 Storing data set hlq.IBM.HHOP951.UI52246 250 Transfer completed successfully 26370480 bytes sent in 0.28 seconds ftp> quit 221 Quit command received. Goodbye.
++HOLD(UI52246) SYS FMID(HHOP951) REASON(ACTION) DATE(17333) COMMENT (**************************************************************** * Affected function: CARMA * **************************************************************** * Description: new variable * **************************************************************** * Timing: post-APPLY * **************************************************************** * Part: /usr/lpp/rdz/samples/CRASRV.properties * * [/etc/rdz/CRASRV.properties] * **************************************************************** This fix updates the sample CRASRV.properties by adding the following optional directives: #connect.timeout Specifies (in seconds) how long CARMA miner (active in RSE) waits for CARMA server (load module CRASERV) to start up and connect to the port on which CARMA miner is listening. The default is 60 seconds. Uncomment and customize to change the wait time. **************************************************************** * Affected function: product registration * **************************************************************** * Description: PARMLIB(IFAPRDxx) update * **************************************************************** * Timing: pre-APPLY * **************************************************************** * Part: sys1.parmlib(IFAPRDxx) * **************************************************************** After applying this fix, Rational Developer for z Systems will be able to register as being a part of "IBM Application Delivery Foundation for z Systems". If you purchased Developer for z Systems as part of product code 5697-CDT, IBM Application Delivery Foundation for z Systems, and have not already done so for another program in product code 5697-CDT, include an entry in the IFAPRDxx parmlib member to enable the related programs. Define PROD=xx in the IEASYSxx parmlib member to specify which IFAPRDxx parmlib member should be used during IPL. Specify the following in IFAPRDxx to define IBM Application Delivery Foundation for z Systems (product code 5697-CDT): PRODUCT OWNER('IBM CORP') NAME('IBM APP DLIV FND') ID(5697-CDT) VERSION(*) RELEASE(*) MOD(*) FEATURENAME(*) STATE(ENABLED) After the IFAPRDxx parmlib member is updated, it can be activated dynamically (until the next IPL) with the following console command: SET PROD=xx **************************************************************** * Affected function: CA Endevor SCM(R) interface * **************************************************************** * Description: new option * **************************************************************** * Timing: post-APPLY * **************************************************************** * Part: FEK.#CUST.PARMLIB(CRACFG) * * [FEK.SFEKSAMP(CRACFG)] * **************************************************************** This fix updates configuration file CRACFG, which is used by Edit support for CA Endevor(R) SCM. # DYNAMIC-FB-DATASET-ALLOC Uncomment and specify YES if some of the CA Endevor(R) SCM TYPE definitions point to fixed blocked (FB) data sets with different (not 80) record lengths (LRECL). Note that enabeling this option impacts performance, as Developer for z Systems will now allocate a work data set with the correct record length for each member being processed. **************************************************************** * Affected function: product registration * **************************************************************** * Description: PARMLIB(IFAPRDxx) update * **************************************************************** * Timing: pre-APPLY * **************************************************************** * Part: sys1.parmlib(IFAPRDxx) * **************************************************************** After applying this fix, Rational Developer for z Systems will be able to register as being a part of "IBM Application Delivery Foundation for z Systems". If you purchased Developer for z Systems as part of product code 5697-CDT, IBM Application Delivery Foundation for z Systems, and have not already done so for another program in product code 5697-CDT, include an entry in the IFAPRDxx parmlib member to enable the related programs. Define PROD=xx in the IEASYSxx parmlib member to specify which IFAPRDxx parmlib member should be used during IPL. Specify the following in IFAPRDxx to define IBM Application Delivery Foundation for z Systems (product code 5697-CDT): PRODUCT OWNER('IBM CORP') NAME('IBM APP DLIV FND') ID(5697-CDT) VERSION(*) RELEASE(*) MOD(*) FEATURENAME(*) STATE(ENABLED) After the IFAPRDxx parmlib member is updated, it can be activated dynamically (until the next IPL) with the following console command: SET PROD=xx).
SMP/E ACCEPT the prerequisites to facilitate an easy backout of the fix, if required. Note that once accepted, you cannot backout the accepted prerequisites.
This step can be skipped if there are no prerequisites, or if there is a reason to not make a prerequisite permanent.
You can accept the prerequisites by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.
//* //* Change #globalcsi to the data set name of your global CSI. //* Change #dzone to your CSI distribution zone name. //* //ACCEPT EXEC PGM=GIMSMP,REGION=0M //SMPCSI DD DISP=OLD,DSN=#globalcsi //SMPCNTL DD * SET BOUNDARY(#dzone) . ACCEPT SELECT( ) REDO COMPRESS(ALL) BYPASS(HOLDSYS,HOLDERROR). //*
SMP/E RECEIVE and APPLY the fix.
You can do this by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.
//* //* Change hlq to the high level qualifier used to upload the fix. //* Change (2x) #globalcsi to the data set name of your global CSI. //* Change #tzone to your CSI target zone name. //* //RECEIVE EXEC PGM=GIMSMP,REGION=0M //SMPCSI DD DISP=OLD,DSN=#globalcsi //SMPPTFIN DD DISP=SHR,DSN=hlq.IBM.HHOP951.UI52246 //SMPCNTL DD * SET BOUNDARY(GLOBAL) . RECEIVE SELECT( UI52246 ) SYSMODS LIST . //* //APPLY EXEC PGM=GIMSMP,REGION=0M //SMPCSI DD DISP=OLD,DSN=#globalcsi //SMPCNTL DD * SET BOUNDARY(#tzone) . APPLY SELECT( UI52246 ) REDO COMPRESS(ALL) BYPASS(HOLDSYS,HOLDERROR). //*
Restart started tasks to activate changes.