AI21624 AI36761 AI38814 AI40871 AI50521 AI56098 AI59418 AI74730 AI87756 UI23674 UI26077 UI27246 UI27582 UI32128 UI35709 UI41258 UI44168 AI21625 AI36767 AI38819 AI40872 AI50523 AI56099 AI59419 AI74734 AI87757 UI23671 UI26078 UI27249 UI27583 UI32129 UI35710 UI41259 UI44169 AI36778 AI38825 AI40877 AI50524 AI56104 AI59420 AI74737 AI87764 UI23675 UI26079 UI27250 UI27584 UI32130 UI35711 UI41260 UI44170 AI31454 AI37279 AI38826 AI39909 AI41042 AI55604 AI56096 AI74747 AI87805 UI23675 UI26044 UI26075 UI27251 UI27581 UI32127 UI35708 UI41257 UI44171

Overview of the installation steps

Steps required to install the fix:

  1. Allocate host data sets for the fix.
  2. Upload the fix from your workstation to z/OS.
  3. SMP/E hold information for the fix.
  4. Perform SMP/E ACCEPT for the prerequisites.
  5. Perform SMP/E RECEIVE and APPLY for the fix.
  6. Restart started tasks to activate changes.

Allocate host data sets for the fix

A sequential data set must be allocated on the z/OS system to receive the fix that you will upload from your workstation. You can do this by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.

//ALLOC    EXEC PGM=IEFBR14
//*
//UI50667    DD DSN=hlq.IBM.HAKG910.UI50667,
//            DISP=(NEW,CATLG,DELETE),
//            DSORG=PS,
//            RECFM=FB,
//            LRECL=80,
//            UNIT=SYSALLDA,
//*            VOL=SER=volser,
//*            BLKSIZE=6160,
//            SPACE=(TRK,(3855,770))
//*
//UI50668    DD DSN=hlq.IBM.HAKG910.UI50668,
//            DISP=(NEW,CATLG,DELETE),
//            DSORG=PS,
//            RECFM=FB,
//            LRECL=80,
//            UNIT=SYSALLDA,
//*            VOL=SER=volser,
//*            BLKSIZE=6160,
//            SPACE=(TRK,(5050,1010))
//*
//UI50669    DD DSN=hlq.IBM.HAKG910.UI50669,
//            DISP=(NEW,CATLG,DELETE),
//            DSORG=PS,
//            RECFM=FB,
//            LRECL=80,
//            UNIT=SYSALLDA,
//*            VOL=SER=volser,
//*            BLKSIZE=6160,
//            SPACE=(TRK,(3817,760))
//*
//UI50670    DD DSN=hlq.IBM.HAKG910.UI50670,
//            DISP=(NEW,CATLG,DELETE),
//            DSORG=PS,
//            RECFM=FB,
//            LRECL=80,
//            UNIT=SYSALLDA,
//*            VOL=SER=volser,
//*            BLKSIZE=6160,
//            SPACE=(TRK,(696,130))
//*

Upload the fix from your workstation to z/OS

Upload the file in binary format from your workstation to the z/OS data set. On a Windows system, you can use FTP from a command prompt to upload the file. In the sample dialog shown below, commands or other information entered by the user are in bold, and the following values are assumed:

User enters: Values
mvsaddr TC P/IP address of the z/OS system
tsouid Your TSO user ID
tsopw Your TSO password
d: Your drive containing the fix files
hlq High-level qualifier that you used for the data set that you allocated in the job above
C:\>ftp mvsaddr
Connected to mvsaddr.
220-FTPD1 IBM FTP CS %version% at mvsaddr, %time% on %date%.
220 Connection will close if idle for more than 60 minutes.
 
User (mvsaddr:(none)): tsouid
331 Send password please.
 
Password: tsopw
230 tsouid is logged on.  Working directory is "tsouid.".
 
ftp> cd ..
250 "" is the working directory name prefix.
 
ftp> cd hlq
250 "hlq." is the working directory name prefix.
 
ftp> binary
200 Representation type is Image
 
ftp> put d:\IBM.HAKG910.UI50667
200 Port request OK.
125 Storing data set hlq.IBM.HAKG910.UI50667
250 Transfer completed successfully
215260080 bytes sent in 0.28 seconds
 
ftp> put d:\IBM.HAKG910.UI50668
200 Port request OK.
125 Storing data set hlq.IBM.HAKG910.UI50668
250 Transfer completed successfully
281965440 bytes sent in 0.28 seconds

ftp> put d:\IBM.HAKG910.UI50669
200 Port request OK.
125 Storing data set hlq.IBM.HAKG910.UI50669
250 Transfer completed successfully
213106160 bytes sent in 0.28 seconds
 
ftp> put d:\IBM.HAKG910.UI50670
200 Port request OK.
125 Storing data set hlq.IBM.HAKG910.UI50670
250 Transfer completed successfully
38855040 bytes sent in 0.28 seconds
 
ftp> quit
221 Quit command received. Goodbye.

SMP/E hold information for the fix

++HOLD(UI50670) SYS FMID(HAKG910) REASON(ACTION) DATE(17270)
   COMMENT
    (****************************************************************
     * Affected function: RSE daemon                                *
     ****************************************************************
     * Description: PARMLIB(IFAPRDxx) update                        *
     ****************************************************************
     * Timing: pre-APPLY                                            *
     ****************************************************************
     * Part: sys1.parmlib(IFAPRDxx)                                 *
     ****************************************************************
     After applying this fix, Rational Developer for System z host
     Utilities (Code Coverage and Code Review) will register with
     z/OS during startup. If registration fails, for example because
     RDzUtil coponents are disabled in SYS1.PARMLIB(IFAPRDxx),
     startup of the RDzUtil components will fail also.
 
     If you purchased Developer for System z Host Utilities as part
     of product code 5697-CDT, IBM Enterprise COBOL Suite for z/OS,
     V1.1 (or later), and have not already done so for another
     program in product code 5697-CDT, include an entry in the
     IFAPRDxx parmlib member to enable the related programs.
     Define PROD=xx in the IEASYSxx parmlib member to specify which
     IFAPRDxx parmlib member should be used during IPL.
 
     Specify the following in IFAPRDxx to define Enterprise COBOL
     Suite for z/OS (product code 5697-CDT):
 
     PRODUCT OWNER('IBM CORP')
     NAME('IBM COBOL SUITE')
     ID(5697-CDT)
     VERSION(*) RELEASE(*) MOD(*)
     FEATURENAME(*)
     STATE(ENABLED)
 
     Alternatively and optionally, if you purchased Developer for
     System z Host Utilities separately (NOT part of Enterprise COBOL
     Suite for z/OS), you may include an entry in the IFAPRDxx
     parmlib member for Developer for System z Host Utilities using
     the stand-alone product code, 5724-T07:
 
     PRODUCT OWNER('IBM CORP')
     NAME('IBM RDZ UTIL')
     ID(5724-T07)
     VERSION(*) RELEASE(*) MOD(*)
     FEATURENAME(*)
     STATE(ENABLED)
 
     After the IFAPRDxx parmlib member is updated, it can be
     activated dynamically (until the next IPL) with the following
     console command:
 
     SET PROD=xx).
  

Perform SMP/E ACCEPT for the prerequisites

SMP/E ACCEPT the prerequisites to facilitate an easy backout of the fix, if required. Note that once accepted, you cannot backout the accepted prerequisites.

This step can be skipped if there are no prerequisites, or if there is a reason to not make a prerequisite permanent.

You can accept the prerequisites by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.

//*
//* Change #globalcsi to the data set name of your global CSI.
//* Change #dzone to your CSI distribution zone name.
//*
//ACCEPT   EXEC PGM=GIMSMP,REGION=0M
//SMPCSI   DD DISP=OLD,DSN=#globalcsi
//SMPCNTL  DD *
   SET BOUNDARY(#dzone) .
   ACCEPT SELECT(
   ) REDO COMPRESS(ALL) BYPASS(HOLDSYS,HOLDERROR).
//*

Perform SMP/E RECEIVE and APPLY for the fix

SMP/E RECEIVE and APPLY the fix.

You can do this by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.

//*
//* Change hlq to the high level qualifier used to upload the fix.
//* Change (2x) #globalcsi to the data set name of your global CSI.
//* Change #tzone to your CSI target zone name.
//*
//RECEIVE  EXEC PGM=GIMSMP,REGION=0M
//SMPCSI   DD DISP=OLD,DSN=#globalcsi
//SMPPTFIN DD DISP=SHR,DSN=hlq.IBM.HAKG910.UI50667
//         DD DISP=SHR,DSN=hlq.IBM.HAKG910.UI50668
//         DD DISP=SHR,DSN=hlq.IBM.HAKG910.UI50669
//         DD DISP=SHR,DSN=hlq.IBM.HAKG910.UI50670
//SMPCNTL  DD *
   SET BOUNDARY(GLOBAL) .
   RECEIVE SELECT(
     UI50667
     UI50668
     UI50669
     UI50670
   ) SYSMODS LIST .
//*
//APPLY    EXEC PGM=GIMSMP,REGION=0M
//SMPCSI   DD DISP=OLD,DSN=#globalcsi
//SMPCNTL  DD *
   SET BOUNDARY(#tzone) .
   APPLY SELECT(
     UI50667
     UI50668
     UI50669
     UI50670
   ) REDO COMPRESS(ALL) BYPASS(HOLDSYS,HOLDERROR).
//*

Restart started tasks to activate changes

Restart started tasks to activate changes.