The fix is shipped as file IBM.HHOP900.UI24427
The fix has rework (build) date 2015015 (15 Jan 2015)
The following fixes are prerequisites for this fix:
These prerequisites can be downloaded from the Developer for System z Recommended Fixes page, if not included as file IBM.HHOP900.<prereq>.
Steps required to install the fix:
A sequential data set must be allocated on the z/OS system to receive the fix that you will upload from your workstation. You can do this by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.
//ALLOC EXEC PGM=IEFBR14 //* //UI24427 DD DSN=hlq.IBM.HHOP900.UI24427, // DISP=(NEW,CATLG,DELETE), // DSORG=PS, // RECFM=FB, // LRECL=80, // UNIT=SYSALLDA, //* VOL=SER=volser, //* BLKSIZE=6160, // SPACE=(TRK,(39,5)) //*
Upload the file in binary format from your workstation to the z/OS data set. On a Windows system, you can use FTP from a command prompt to upload the file. In the sample dialog shown below, commands or other information entered by the user are in bold, and the following values are assumed:
User enters: | Values |
---|---|
mvsaddr | TC P/IP address of the z/OS system |
tsouid | Your TSO user ID |
tsopw | Your TSO password |
d: | Your drive containing the fix files |
hlq | High-level qualifier that you used for the data set that you allocated in the job above |
C:\>ftp mvsaddr Connected to mvsaddr. 220-FTPD1 IBM FTP CS %version% at mvsaddr, %time% on %date%. 220 Connection will close if idle for more than 60 minutes. User (mvsaddr:(none)): tsouid 331 Send password please. Password: tsopw 230 tsouid is logged on. Working directory is "tsouid.". ftp> cd .. 250 "" is the working directory name prefix. ftp> cd hlq 250 "hlq." is the working directory name prefix. ftp> binary 200 Representation type is Image ftp> put d:\IBM.HHOP900.UI24427 200 Port request OK. 125 Storing data set hlq.IBM.HHOP900.UI24427 250 Transfer completed successfully 2130080 bytes sent in 0.28 seconds ftp> quit 221 Quit command received. Goodbye.
++HOLD(UI24427) SYS FMID(HHOP900) REASON(ACTION) DATE(15015) COMMENT (**************************************************************** * Affected function: CA Endevor SCM(R) interface * **************************************************************** * Description: new option * **************************************************************** * Timing: post-APPLY * **************************************************************** * Part: FEK.#CUST.PARMLIB(CRACFG) * * [FEK.SFEKSAMP(CRACFG)] * **************************************************************** This fix updates configuration file CRACFG, which is used by Edit support for CA Endevor SCM(R). # ALTERNATIVE-ALLOC Uncomment to use an alternative allocation mechanism for those situations where the data sets that are being created for use by the client are locked exclusively by the CARMA server. **************************************************************** * Affected function: CA Endevor SCM(R) interface * **************************************************************** * Description: new option * **************************************************************** * Timing: post-APPLY * **************************************************************** * Part: FEK.#CUST.PARMLIB(CRACFG) * * [FEK.SFEKSAMP(CRACFG)] * **************************************************************** This fix updates configuration file CRACFG, which is used by Package Editor for CA Endevor SCM(R). PACKAGE-EDITING-OPTION = READONLY PACKAGE-EDITING-OPTION = DISABLED Uncomment one of the options if you need to restrict how CA Endevor(R) Packages are processed. Set the PACKAGE-EDITING-OPTION to READONLY to force the Developer for System z Packages Editor to only open a Package in browse mode. Set the PACKAGE-EDITING-OPTION to DISABLED to prevent a Package from being opened in the Developer for System z Packages Editor. SCL-REQUIRED = YES Uncomment to require that an SCL template must be present to edit a CA Endevor(R) Package. SCL-DATASET-TEMPLATE = FEK.#CUST.PARMLIB(CRASCL) Uncomment and specify the name of a template SCL if some actions or some parameters are not allowed when CA Endevor(R) Packages are processed. The template SCL can be a sequential data set or a member. The template SCL must lists the valid actions and options. Other information in the template SCL, like element name or environment, is ignored by the Developer for System z Packages Editor. **************************************************************** * Affected function: CA Endevor SCM(R) interface * **************************************************************** * Description: new option * **************************************************************** * Timing: post-APPLY * **************************************************************** * Part: FEK.#CUST.PARMLIB(CRASCL) * * [FEK.SFEKSAMP(CRASCL)] * **************************************************************** This fix defines a sample SCL template, CRASCL, which is used by Package Editor for CA Endevor SCM(R). When used, this template SCL will limit which actions and options are allowed when CA Endevor(R) Packages are processed. The template SCL must lists the valid actions and options. Actions and options that are not listed will not be allowed to be specified in the Developer for System z Packages Editor. Other information in the template SCL, like environment or element name, is ignored by the Developer for System z Packages Editor. For example, in order to prevent an action from being accessed in the Packages Editor, that action would be removed from the SCL template. In order to prevent an OPTIONS parameter from being used in certain actions, this OPTIONS parameter would be removed from the template SCL for these actions. Other OPTIONS parameters would continue to be allowed, if they are specified in the template SCL. Note for mutually exclusive OPTIONS parameters: For actions that contain OPTIONS parameters that are mutually exclusive (for example, SEARCH and NOSEARCH), the action is specified more than once in the template SCL, once for each of the OPTIONS parameters that can only be specified exclusive of the other. There is no need to specify the non-exclusive OPTIONS parameters more than once for each of the repeated action. For example, if an action accepts SEARCH and NOSEARCH as OPTIONS parameter, the action is once specified with the SEARCH parameter and all other non-exclusive parameters, and once with the NOSEARCH parameter without the non-exclusive parameters.).
SMP/E ACCEPT the prerequisites to facilitate an easy backout of the fix, if required. Note that once accepted, you cannot backout the accepted prerequisites.
This step can be skipped if there are no prerequisites, or if there is a reason to not make a prerequisite permanent.
You can accept the prerequisites by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.
//* //* Change #globalcsi to the data set name of your global CSI. //* Change #dzone to your CSI distribution zone name. //* //ACCEPT EXEC PGM=GIMSMP,REGION=0M //SMPCSI DD DISP=OLD,DSN=#globalcsi //SMPCNTL DD * SET BOUNDARY(#dzone) . ACCEPT SELECT( UI20613 UI14892 UI13095 ) REDO COMPRESS(ALL) BYPASS(HOLDSYS,HOLDERROR). //*
SMP/E RECEIVE and APPLY the fix.
You can do this by submitting the job below. Add a job card and modify the parameters to meet your site's requirements before submitting.
//* //* Change hlq to the high level qualifier used to upload the fix. //* Change (2x) #globalcsi to the data set name of your global CSI. //* Change #tzone to your CSI target zone name. //* //RECEIVE EXEC PGM=GIMSMP,REGION=0M //SMPCSI DD DISP=OLD,DSN=#globalcsi //SMPPTFIN DD DISP=SHR,DSN=hlq.IBM.HHOP900.UI24427 //SMPCNTL DD * SET BOUNDARY(GLOBAL) . RECEIVE SELECT(UI24427) SYSMODS LIST . //* //APPLY EXEC PGM=GIMSMP,REGION=0M //SMPCSI DD DISP=OLD,DSN=#globalcsi //SMPCNTL DD * SET BOUNDARY(#tzone) . APPLY SELECT(UI24427) REDO COMPRESS(ALL) BYPASS(HOLDSYS,HOLDERROR). //*
Restart started tasks to activate changes.