Intelligent Decision Server 1.0.1 and 1.0.0 OS/2 Server and Workstation Fixes NOTE: Fix level "go786" requires a DB2 bind if you are using an OS/2 database gateway. See the instructions in README.TXT one directory up from this file. NOTE: If you have a Unix database gateway, then you must install fix level "gd786" from ...\v101\dbgw after installing "go786". Problems that are fixed by the "go786" fix level: 37761- Having font size larger than 10 pt causes the controls window to display incorrectly. User has to resize window, the scroll up & down button is not present. 37858- Spreadsheet titles not printing correctly when multiple rows and columns are defined. For example, if rows 1-9 & columns A-H are defined, the title set prints 1/2 inch off. So the title starts in the middle of cell A1 instead at the left margin. 37937- DB2/2 DRDA connect to database limited to bind userid. DB2/2 DRDA gateways are not providing a mechanism to arrive into destination database as various userids. 37976- Incorrect region name defined in arrow to Spreadsheet does not fail with an error. 38069- Changing the password to the Database Gateway services console (SA Tool), becomes the only password available for the console. The realm password can no longer be used to obtain the Database Gateway console. 41269- Elevator scroll button in transformer controls window doesn't work if Save Output =NO. 41276- Changing headings to exclude option from Some to None is ignored by Reporter. 41279- Exclude from calculation option will not accept a value when a Constant is used as the second operator of a binary calculation. (Reporter Tool) 41284- In a Reporter, no SQL is generated when the NULL or NOT NULL constraint operators are selected. 41301- ITERATION Spreadsheet does not fail with an error when there are no values defined for the Iteration. (The Query tool does give an error message: Too few row [controls] for ITERATION..correct controls or keyword.) This same error message should be displayed when the Spreadsheet has no values for the Iteration. 41419- Spreadsheet region will not expand beyond blank rows. For example, Any data following a blank row will not transfer to a SS region. 41479- Reporter column width will not accept decimal precisions greater than .00. 41484- Reporter -> Layout combination not flagged as an error. An error should display when trying to connect a Reporter -> Layout in a capsule. 41498- IDS resets when running a capsule that transfers a Spreadsheet to a PC Application tool using DDE. 41523- Data Entry with Post Entry SQL will reset IDS when it is moved out of the capsule and double clicked to open. 41572- Unable to open a Query or Reporter tool when accessing DB2/400. 41579- When a blank row is copied to another blank row in a Spreadsheet, a reset occurs. 41586- Data Format transformer not aligning 1st column of data correctly. 41659- Clear function in Spreadsheet ends with an error: 'Cannot transfer data from capsule'. 41665- Data Entry tool inserting incorrect decimal data. 41691- Reporters with Indented Sub-Row option will transfer only Column and Row heading only. The data will not transfer over. 41692- Data Entry using Post Entry SQL generates error: 'Data type retrieved by colval function is not supported by SQL Tool'. Post Entry SQL does &SET @X=colval (1), subsequent to a select of a date field receives above error message. 41747- In Set Preferences on desktop, no error message is given when both the thousands and decimal separators are the same. 41809- Calculator does not accept comma as a decimal separator. 41916- Footers 64+ characters long in a Spreadsheet resets IDS. 41924- Layout calculated columns transferred incorrectly to Spreadsheet. 41930- TAPELISTING command on PFS issued against the 8mm drive, causes Directory Service to abend with GPF. 41949- ODAS OS/2 C API receiving MET0085 error message using the DisGetMultiObject function. 42037- OCS Service Manager continually exits with RC=4 when running at the same time with Novell Netware. 42049- Graphic for comma separator in Calculator looks to much like a "/". 42107- A Data Entry with a very large Post Entry SQL receives an error: "SQL-198, the PREPARE or EXECUTE IMMEDIATE statement is blank or empty". Problems that are fixed by the "go74L" fix level: 41364- A Spreadsheet with just row headings and no data rows fails when transferring the data into a query in the capsule environment. The error states that the data type is a mismatch in the SS. This is causing capsules that ran to completion in 1.3 to stop in 2.11. If this process is done by manual steps there is no error. 41515- The file server console (fscnsl) may take up the entire CPU on some systems causing a slow down of processes. This problem had been introduced in the 1.0 version because the fscnsl logs on as a super user during initialization to perform a new function. 41564- Empty rows in Spreadsheet creates extra tabs in Text tool. For example, a SS with a region of 1000 rows, but only 350 rows have data in them with 10 columns. The rows with data have 9 tabs and a carriage return, rows without data have 10 tabs then a carriage return. 41571- SA Tool displays debug buttons. 41574- Allowed more than one SA Tool to open. 41615- Realm number in the Show Realm Information window displays garbled. (SA Tool) 41621- A constrained column in the Browser tool does not reset correctly. 41628- Missing files for French 189 keyboard. 41638- Text to Spreadsheet transformer is not retaining format. Numeric data is aligning incorrectly and not rounding when it should be. 41667- Need a new binary keyboard table with French 189 included. Problems that are fixed by the "go701" fix level: 38065- In a Spreadsheet you cannot duplicate a formula across columns. 38067- In Spreadsheet Options window, change "NUMBER PRECISION" from DISPLAYED TO FULL. Column totals do not reflect the new precision selected. 40106- Selecting the Show Size or Update Quota Status button results in an IDS reset. 41155- Disk Statistics not working. 41177- Using a Data Entry that accesses an empty PESQL document will result in an IDS reset. 41256- In the SQL entry, when specifying 'data types' in lower case for the &CONSTRAINT function, results in an IDS reset. 41294- An IDS reset occurs when the source icon for data transfer in a capsule is an embedded capsule which does not execute (an embedded capsule will not execute if the "CLEAR" keyword is arrowed into its control region-refer to the Capsule manual for an explanation of this capability.)