Data Interpretation System (DIS) 2.1.1 OS/2 Server and Workstation fixes Problems fixed in the "6c6" fix level: 37700- A black box prints on a Plot if @variables are used & the title frame text is larger than the frame. 37884- Cannot download a Spreadsheet (WK1) to the 4th level of a directory using PCDir. 37903- The WriteSQL transformer is not transferring character values, instead a user would see ' ' . 37910- Two problems were found: 1) Opening a Reporter icon from customer results in a reset. 2) This same Reporter when sent to a printer, the report looks fine but all the column headings are garbled. 37919- The Data Entry SQL is missing the table name so the Data Entry ends with an error. 37938- The error message "Unable to open Spreadsheet" displays when a SS (Spreadsheet) with a lengthy formula that does not exceed the 400 character limitation, but when "tokenized", would cause the formula strings to exceed that limitation. 37943- Capsule Run Log not displaying the time of a Capsule run when desktop preference is set to display Date Only. A user would be required to change their desktop preference to display Date and Time, which is incorrect. 37950- Print services not able to start on Pentiums. 37959- In a Query the F9 key fails to cancel DB2 host query. The F9 function works in the APPC Gateway, but the cancel request never reaches the host. 37965- A Reference Capsule executed using this particular setup: SS->Out->Capsule->SS, causes a reset. Manually copying data from one SS to another SS also causes a reset. 37970- When using a Query to insert data into a DB, fails when the decimal precision is greater than 15. 37971- Create column function in the Query sends the internal name of a column to the DB server. It should use the sqlname as it is designed to do. 37978- A SS in a capsule transferring no data to another SS with a region name defined in the arrow options, results in a reset. Example: SS1->SS2->SS3->. There are no regions defined in any of the SSs. SS1 connected to SS2 has a region name defined in the connecting arrow. SS2 connected to SS3 has no region names defined (All Data) in the connecting arrow. 37979- Primary File Server (PFS), will not start service after first shutdown from initial installation of 3rd drive volume. The CATRANS.EXE file caused a memory leak prohibiting other service processes of the PFS to continue after initializ completes. The memory leak also slows down the PFS's performance and may eventually disconnect or stop dependent services. 37989- The 'All' default in the controls window of the Replace transformer does not work. 37990- A problem was found where the SQL entry tool fails when the source document name is longer than 30 characters. 37992- WriteSQL transformer missing and truncating column names. It was found that the WriteSQL transformer has a limitation in the Insert field in the transformers main window. Limitation is set to 255 chars. User's are instructed to use the Insert parameter in the Controls of the transformer-this has a 456 char limitation. 37994- SQL entry receives an error message with the &label function. Problem seems to occur when a previously parsed label is encountered again after a goto statement. 38008- The Computed date column within a Query has a Metaphor date resolution set to Month but displays results as MDY(12/1/96), when it should display the results as MY(12/96). 38009- Constraining in the header or column header areas of the reporter on a dimension key does not constrain the fact key as it did in DIS 1.3.X. 38015- A reset occurs when a SS, which contains a formula that results in an error, is transferred to the PC Directory. 38017- Date values not accepted by Data Entry, even though the date value displays as a choice in the browser list. Error message displayed: "DTEN:001-0116 Error'April 24, 1993' is not a valid value. 38023- When a capsule is executed using this particular setup: SS->Out->Capsule->SS, a reset occurs if the first SS has a cell ' =ERROR'. 38024- When an SQL entry tool receives no data, and the user selects on the scroll bar, a reset occurs. 38025- Calculations including a blank cell received incorrect results. i.e. if (A1="",A1+100,"") this gave a result of blank in a SS, which is incorrect. Correct result should be 100. 38034- Copying columns from one SS to another SS causes a reset. 38037- Script command fails when executed from the file server console. 38043- A formula within a SS that results in 'Error' does not copy over to a new cell. 38048- Replicating on copied blank cells in a SS causes a reset. 38053- Some migrated capsules cause a reset to occur when attempting to open. 38079- Text document imported to RTF then to Lotus Notes, looses tab formats. The document changes and the tabs are no longer in the right places. 40137- The Custom Browse feature in the Data Entry (DE) does not work. 40151- When using the &Date() with &Constraint function in the SQL Entry tool, in this order, corrupts the SQL and produces incorrect SQL. 40162- Desktop preferences set for 2 decimal places and the Fact table is constrained for a dollar amount of 99999.99, the sql returned is ############. 41007- An incomplete write to the Asset Manager increases time out and drops packet size. 41048- Updating and copying existing Forms Design tool results in all changes being lost. (Summary: Open, update, close, copy, open, update, close, open. All updates are gone.) 41097- A capsule with a Reporter connected to a Text icon results in a reset. The reset only occurs on Reporter's with added text fields included in it's report. 41177- When opening a Data Entry that accesses an empty PESQL document, results in a reset. 41214- Reporter SQL built does not include constraints on the inlist resulting in an SQLCODE156 error. 41224- An incomplete write to the Asset Management DB will hang the Asset Manager.