Snapshot Level Database Manager |
Logical Data Grouping fcm |
Monitor Switch Basic |
Resettable |
No |
|
Element Name Element Type |
MA_free gauge |
Description: This element indicates the number of message anchors currently free.
Usage: Use the number of message anchors currently free in conjunction with the fcm_num_anchors configuration parameter to determine the current message anchor utilization. You can use this information to tune fcm_num_anchors.