In the "Health indicators summary" topic in the DB2 Information Center for Version 8.2.2 (equivalent to Version 8.1 FixPak 9), the identifier for the Database automatic storage utilization health indicator is incorrectly documented as db.db_auto_storage_util.
The correct identifier for the Database automatic storage utilization health indicator is db.auto_storage_util.
It is possible to see decoupled applications when issuing the list applications command even without connection concentrator enabled.
Progress monitoring of runtime rollback provides progress information of rollback events using application snapshots. Rollback events are of two types:
The information provided is the start time of the rollback event, the total work to be done, and completed work. The work metric is bytes.
Total Work units is the range in the log stream that needs to be rolled back for the transaction or savepoint.
Completed Work units shows the relative position in the log stream that has been rolled back.
Updates to Completed Work are made after every log record is processed. Updates are not performed evenly because log records vary in size.
Application Snapshot Application handle = 6 Application status = Rollback Active Start Time = 02/20/2004 12:49:27.713720 Completed Work = 1024000 bytes Total Work = 4084000 bytes Application Snapshot Application handle = 10 Application status = Rollback to Savepoint Start Time = 02/20/2004 12:49:32.832410 Completed Work = 102400 bytes Total Work = 2048000 bytes