********************************************************************************** * * * Tivoli Software Distribution 3.1.5 for OS/2 * * * * README CSD XR21926 * * * * * ********************************************************************************** This patch is created in order to deliver an enhancement to SAN PAOLO IMI and it is going to solve the memory Activate problem for the OS/2 Systems running on particular machines like Netfinity Server and Digital. The enhancement request has the following description: "The product is requested to be able to perform the activate function in an environment where hardware involved is Netfinity Server 3000 and software is OS/2, SES and Sentry." ********************************************************************************** * * * Prerequisites. * * * ********************************************************************************** The CSD XR21926 must be installed on top of Tivoli Software Distribution 3.1.5 or Tivoli Software Distribution 3.1.3 + CSD XR21925. ********************************************************************************** * * * What is in CSD XR21926? * * * ********************************************************************************** Let us suppose that the CD drive is F. The content of the CSD XR21926 is the following: F:. | | Readme.txt | |________sd4os2 |__________clt | fndcmam.exe | fndcmam.ex_ | |__________srv fndcmam.exe fndcmam.ex_ ********************************************************************************** * * * How to install it on a client. * * * ********************************************************************************** Let us suppose that you have Software Distribution 3.1.5 installed on the drive D and that the CD drive is F. In order to have the level of code updated to the CSD XR21926: 1) stop the product 2) rename the file D:\Softdist\bin\fndcmam.exe in D:\Softdist\bin\fndcmam.bak 3) copy F:\sd4os2\clt\fndcmam.exe in D:\Softdist\bin ********************************************************************************** * * * How to install it on a server. * * * ********************************************************************************** Let us suppose that you have Software Distribution 3.1.5 installed on the drive D and that the CD drive is F. In order to have the level of code updated to the CSD XR21926: 1) stop the product 2) rename the file D:\Softdist\bin\fndcmam.exe in D:\Softdist\bin\fndcmam.bak 3) copy F:\sd4os2\srv\fndcmam.exe in D:\Softdist\bin ********************************************************************************** * * * How to refresh the Code images * * * ********************************************************************************** Let us suppose to have the code images under directory: D:\CID\IMG\SD4OS2\IMAGES In order to refresh the code images you have to do the following: 1) copy F:\SD4OS2\SRV\FNDCMAM.EX_ D:\CID\IMG\SD4OS2\IMAGES\SRV 2) copy F:\SD4OS2\CLT\FNDCMAM.EX_ D:\CID\IMG\SD4OS2\IMAGES\CLT