*********************** * SUBSET HPRF320 * *********************** This subset contains installation information for PSF FOR OS/390 Version 3, Release 2, Modification 0. ************************************************************************ * C H A N G E S U M M A R Y * ************************************************************************ DATE LAST CHANGED SECTION 1. 01/07/17 INSTALLATION INFORMATION 2. YY/MM/DD DOCUMENTATION CHANGES NO ENTRIES 3. 03/02/05 GENERAL INFORMATION 4. 03/11/17 SERVICE RECOMMENDATIONS 5. 02/10/23 CROSS PRODUCT DEPENDENCIES SERVICE RECOMMENDATION SUMMARY DATE APAR PTF VOLID COMMENTS 11 03/11/17 OW57627 UA00648 0301 HIPER LOOP IN PSF IF $PPRTXX IS 10 03/10/03 OA04986 UA05855 0310 HIPER PSF ISSUES DISCONNECT EVEN 9 03/09/22 OA04428 UA05429 0309 HIPER LOST PAGES OF OUTPUT IF 8 03/07/17 OW57132 UA00685 0301 HIPER APSRDEL TIGHT LOOP AFTER 7 02/07/31 OW54617 UW89192 0205 HIPER INCORROUT JOB TERMINATED 6 01/09/27 OW50892 UW82771 0109 HIPER INCORROUT IF USING 5 01/06/22 OW48960 UW79677 0105 HIPER ABEND024 RC08A9 OR 4 00/11/01 OW46544 UW74880 0010 HIPER MSGIOS000I IOE COMMAND = 3 00/11/01 OW46732 UW74867 0010 HIPER ABEND0C4 PIC4 APSPEFSS 2 00/09/20 OW46182 UW73825 0009 HIPER ABENDA00 ABEND0C4 PIC4 IN 1 00/08/25 OW45610 UW73127 0008 HIPER ROLL UP FIXES FROM ************************************************************************ * SECTION 1. I N S T A L L A T I O N I N F O R M A T I O N * ************************************************************************ This section contains changes to the product's Program Directory. 4. 01/07/17 SECTION OF PROG. DIRECTORY REFERENCED: 6.2.1.1, IVP Job for JES Environment, Paragraph (2.) Note: The sample startup procedures specify coded font X060D8 in it's 4 character form 60D8 as the default font for Job Headers, Job Trailers, Dataset Headers, and Dataset Trailers. This font is currently part of Functional Requisite: AFP Font Collection 2. This font must be available to the PSF startup JCL procedure for correct functioning of the APSIVP job at runtime when separator pages are specified. 3. 01/03/19 SECTION OF PROG. DIRECTORY REFERENCED: 5.4.1 Special Considerations WARNING: If you choose to install PSF 3.2.0 into a different CSI than the OS/390 Product set, you may be unable to define Channel Attached printers via HCD. The PSF 3.2.0 Device Support modules MUST reside in SYS1.NUCLEUS. 2. 01/03/12 EXPECTED RETURN CODES and MESSAGEs - RC'04' may be received for APPLY CHECK, APPLY and ACCEPT processing if maintenance is being installed with the base product and the BYPASS option is used. Any warning mesages may be ignored. 1. 01/01/18 PROGRAM DIRECTORY addition: Section 5.4.2.3.1 BUFNO Parameter in Startup Procedures: The ability to specify BUFNO values of 1 thru 4 and above 100 (new with this release of PSF) requires the appropriate ptf for MVS SCHEDULER APAR OW35684 be applied to your DRIVING SYSTEM. ************************************************************************ * SECTION 2. D O C U M E N T A T I O N C H A N G E S * ************************************************************************ This section outlines major errors in the product's published documentation. 1. YY/MM/DD NO ENTRIES ************************************************************************ * SECTION 3. G E N E R A L I N F O R M A T I O N * ************************************************************************ This section contains general information, i.e. SYSGEN hints/tips. 2. 00/11/28 --------------+---------------+----------------+ Feature UPGRADE SUBSET(s) --------------+---------------+----------------+ PSF base PSFMVS320 HPRF320 --------------+---------------+----------------+ Netspool NETSPOOL HPRF226/9704 HPRF226/0044 JPRF228 JPRF229 --------------+---------------+---------------- MVS Download PSFMVS320 JPRF322 --------------+---------------+----------------+ AFPUPLOAD AFPUPLOAD HPRF227/9824 --------------+---------------+----------------+ ACIF ACIF HQN2110/9846 HQN2110/0044 --------------+---------------+----------------+ IP PrintWay PRINTWAY HMOS100/9704 JMOS101 JMOS102 HMOS100/0044 --------------+---------------+----------------+ *** NOTE *** If you have any of the following FMID'S applied to your system _____________________________________________________ Printway HMOS280, JMOS28J, JMOS28S ----------------------------------------------------- Netspool HNET280, HNET28J, HNET28S ----------------------------------------------------- Print Server HOPI280, HOPI28J, HOPI28S ----------------------------------------------------- see the OS/390 Version 2 Release x Program Directory and UPGRADE: OS390Rx SUBSET:INFOPRINT for information regarding the INFOPRINT product and the above FMID's. If you have the following FMID's applied to your system ----------------------------------------------------- PRINTWAY HMOS705, JMOS7J5 ----------------------------------------------------- Netspool HNET705 ----------------------------------------------------- Print Server HOPI705 ----------------------------------------------------- See the Zos Version 1 Release X Program Directory and the UPGRADE:ZOSV1RX SUBSET:INFOPRINT for information regarding the INFOPRINT product and the above FMID's. 1. 00/11/03 ALL PSF/MVS 320 USERS WHO INSTALL WITH TCP/IP 3.4 AND ABOVE MSGAPS935I CONNECTION WITH TCP/IP ATTACHED PRINTER IPADDR(XXX.XXX.XXX.XX) IS BEING RETRIED BECAUSE OF A PREVIOUSLY DETECTED RETRIABLE CONDITION (SOCKET FAILED), TCP/IP ERRNO(156) MAY BE RECEIVED. ********************************************************* ERRNO 156 indicates an OpenEdition process initialization failure. This is usually an indication that a proper OMVS RACF SEGMENT is not defined for the USER-ID associated with the application. The PSF RACF USERID MUST be defined in the OMVS RACF SEGMENT and contain a proper HOME directory and the directory MUST be MOUNTED. * Please review IP PLANNING & MIGRATION manual, SC31-8512, pages 33 thru 38, TOPICS, 'OPEN EDITION SECURITY CONSIDERATIONS' and 'REQUIREMENTS FOR AN OMVS SEGMENT'. The PSF RACF USERID MUST be defined in the OMVS RACF SEGMENT and contain a proper HOME directory. ************************************************************************ * SECTION 4. S E R V I C E R E C O M M E N D A T I O N S * ************************************************************************ 11 03/11/17 PROBLEM: (OW57627) LOOP IN PSF IF $PPRTXX IS ISSUED WHILE PSF IS IN RESTART PROCESSING FOR ANOTHER RESTARTABLE ABEND USERS AFFECTED: All users of PSF version 3 for OS/390 and Download version 3 for for OS/390. RECOMMENDATION: INSTALL UA00648 ON VOLID 0301 (HPRF320) 10 03/10/03 PROBLEM: (OA04986) PSF ISSUES DISCONNECT EVEN THOUGH DISCINTV=0 AFTER OA04428 OR ISSUES NPRO TO CHANNEL PRINTER USERS AFFECTED: All PSF Version 3 for OS/390 users. RECOMMENDATION: INSTALL UA05855 ON VOLID 0310 (HPRF320) 9 03/09/22 PROBLEM: (OA04428) LOST PAGES OF OUTPUT IF PAPER JAM OCCURS AFTER DISCONNECT INTERVAL EXPIRES. USERS AFFECTED: All PSF Version 3 for OS/390 customers. RECOMMENDATION: INSTALL UA05429 ON VOLID 0309 (HPRF320) 8 03/07/17 PROBLEM: (OW57132) APSRDEL TIGHT LOOP AFTER OUT OF STORAGE NACK FROM PRINTER. USERS AFFECTED: All PSF version 3 for OS/390 users. RECOMMENDATION: INSTALL UA00685 ON VOLID 0301 (HPRF320) 7 02/07/31 PROBLEM: (OW54617) INCORROUT JOB TERMINATED AFTER PAPER JAM IF MESSAGE DATASET USES A DUPLEX FORMDEF AND PRINTER IS IN SIMPLEX USERS AFFECTED: PSF version 3 for OS/390 users. RECOMMENDATION: INSTALL UW89192 ON VOLID 0205 (HPRF320) 6 01/09/27 PROBLEM: (OW50892) INCORROUT IF USING RELATIVE POSITIONING WITH FIELD FORMATTING AFTER APPLICATION OF UW75957 OR UW76259 USERS AFFECTED: All PSF 3.1.0 and PSF 3.2.0 for OS/390 users who use FIELD formatting with relative positioning and have applied UW75956 or UW76476 for PSF 3.1.0 or UW75957 or UW76259 for PSF 3.2.0. RECOMMENDATION: INSTALL UW82771 ON VOLID 0109 (HPRF320) 5 01/06/22 PROBLEM: (OW48960) ABEND024 RC08A9 OR UNPREDICTABLE RESULTS WHEN PRINTING A JOB THAT WAS CHECKPOINTED WITH PSF V320 ON A PSF V310 SYSTEM. USERS AFFECTED: PSF 3.1.0 for OS/390 users and PSF 3.2.0 for OS/390 users. RECOMMENDATION: INSTALL UW79677 ON VOLID 0105 (HPRF320) 4 00/11/01 PROBLEM: (OW46544) MSGIOS000I IOE COMMAND = X'3F' WHEN TRYING TO START D/T3800 USING PSF V320. V310 WORKS FINE. USERS AFFECTED: All PSF 3.2.0 for OS/390 users who are using 3800 printers or a DPF or RPM3 intermediate device. RECOMMENDATION: INSTALL UW74880 ON VOLID 0010 (HPRF320) 3 00/11/01 PROBLEM: (OW46732) ABEND0C4 PIC4 APSPEFSS UPON STARTING PSF V320 OR DOWNLOAD V320 AND ABEND IS ACTUALLY IN BPXJCPR OR OTHER OE MODULES. USERS AFFECTED: All PSF 3.2.0 for OS/390 users and all Download 3.2.0 for OS/390 users. RECOMMENDATION: INSTALL UW74867 ON VOLID 0010 (HPRF320) 2 00/09/20 PROBLEM: (OW46182) ABENDA00 ABEND0C4 PIC4 IN APSCPCIA AT X'10C' IF PSF IS IN LPA AND ABEND073 RC08 IF IN LINKLIB AFTER PTF UW71465 USERS AFFECTED: All users of PSF 3.1.0 and 3.2.0 for OS/390. RECOMMENDATION: INSTALL UW73825 ON VOLID 0009 (HPRF320) 1 00/08/25 PROBLEM: (OW45610) ROLL UP FIXES FROM ANNOUNCE TO GA FOR PSF 3.2.0 FOR OS/390 USERS AFFECTED: All PSF 3.2.0 for OS/390 users and all Download 3.2.0 for OS/390 users. RECOMMENDATION: INSTALL UW73127 ON VOLID 0008 (HPRF320) ************************************************************************ * SECTION 5. C R O S S P R O D U C T D E P E N D E N C I E S * ************************************************************************ This section contains information that is dependent upon another product other than this subset ID. It also contains information dealing with migration and product coexistance. 3. 02/10/23 INTERDEPENDENT PRODUCT: JES2 5752SC1BH R707 HJE7707 PROBLEM: Abend024 rc0130 after getrec issued by PSF for jes2 spool. USERS AFFECTED: All running PSF or Printway with JES2. SEE HIPER JES2 APAR OW56657. RECOMMENDATION: INSTALL UW94738 ON VOLID 0210 2. 02/10/23 INTERDEPENDENT PRODUCT: JES2 5752SC1BH R707 HJE7707 PROBLEM: Missing pages if FSS application requests specific record. USERS AFFECTED: All running PSF or Printway with JES2. SEE HIPER JES2 APAR OW56732. RECOMMENDATION: INSTALL UW94733 ON VOLID 0210 1. 00/11/03 INTERDEPENDENT PRODUCT: JES2 5752SC1BH R607 R608 HJE6607 HJE6608 PROBLEM: Lost data if printing LINE MODE type data or possible PSF messages MSGAPS033I, MSGAPS159I, MSGAPS104I and MSGAPS348I indicating records OUT OF SEQUENCE. USERS AFFECTED: All running PSF with JES2 SEE HIPER JES2 APAR OW42126 for details RECOMMENDATION: INSTALL UW67889 ON VOLID F003 (HJE6607) INSTALL UW67890 ON VOLID F003 (HJE6608) ************************************************************************ * I N F O R M A T I O N A L / D O C U M E N T A T I O N * * APARS FOLLOW (IF ANY) * ************************************************************************ --PTF INCLUDE LIST-- --PTF EXCLUDE LIST-- --PE APAR LIST--