*********************** * SUBSET DCF/143 * *********************** THIS SUBSET CONTAINS INSTALLATION INFORMATION FOR DCF/DOUBLE BYTE FEAT VERSION 1, RELEASE 4, MODIFICATION 0. ************************************************************************ * C H A N G E S U M M A R Y * ************************************************************************ DATE LAST CHANGED SECTION 1. YY/MM/DD INSTALLATION INFORMATION NO ENTRIES 2. YY/MM/DD DOCUMENTATION CHANGES NO ENTRIES 3. 94/06/02 GENERAL INFORMATION 4. YY/MM/DD SERVICE RECOMMENDATIONS NO ENTRIES 5. YY/MM/DD CROSS PRODUCT DEPENDENCIES NO ENTRIES SERVICE RECOMMENDATION SUMMARY DATE APAR PTF VOLID COMMENTS 1. YY/MM/DD XXXXXXX XXXXXXX XXXX XXXXXXXXX ************************************************************************ * SECTION 1. I N S T A L L A T I O N I N F O R M A T I O N * ************************************************************************ THIS SECTION CONTAINS CHANGES TO THE PRODUCT'S PROGRAM DIRECTORY. 1. YY/MM/DD NO ENTRIES ************************************************************************ * SECTION 2. D O C U M E N T A T I O N C H A N G E S * ************************************************************************ THIS SECTION OUTLINES MAJOR ERRORS IN THE PRODUCT'S PUBLISHED DOCUMENTATION. 1. YY/MM/DD NO ENTRIES ************************************************************************ * SECTION 3. G E N E R A L I N F O R M A T I O N * ************************************************************************ THIS SECTION CONTAINS GENERAL INFORMATION, I.E. SYSGEN HINTS/TIPS. 4. 94/06/02 Apar PN55930 changes how the AFPDS is produced when formatting for any of the following families of logical devices: AFP, 3820, PG1, PG2, PG3, PG4, and 38PP. Prior to this apar each different section of the page was placed in a separate CTX/PTX structured field. This sections include, but are not limited to: columns, floats, cells in tables, areas, footnotes, running headings, and running footings. PN55930 changes processing to put as much data into a CTX/PTX structured field as possible. This means that fewer CTX/PTX structured fields will be produced, the output files produced by SCRIPT/VS will be smaller, and printer performance should be improved. 3. 92/04/28 Apar PN17455 contains five fixes for double byte, including apar PN11639. As a suggestion, it may be easier for a user to resolve the problem corrected by mandatory apar PN11639 and resolve other double byte problems by installing apar PN17455. 2. 92/04/22 When creating a saved segment for DCF 1.4 with the DEFSEG command the program directory shows a size of x'BF'. This size is large enough for base DCF, maintenance and one language. If you include more than one language or a feature such as SMFF and double byte, you will need to increase the size of your segment accordingly. Failure to do so may result in message msdmsitp141t indicating an operation exception has occurred. If you install base DCF, maintenance, the Double Byte feature, SMFF and the Dutch language (this is the largest language), you will need a segment size of x'CF' instead of x'BF'. 1. 92/04/22 If you are installing the Double Byte feature for VM and VM/SMFF, you must install apars PN11639, PN17455 and PN18084. If PN11639 is not installed, message MSDSMBEG201W 'SOSI Specified With Incompatible Command Option, SOSI Option Ignored' is issued for the IVP because the profiles have not been updated for Double Byte. Also, message MSDSMACT203S 'Invalid Calling Sequence (NO.=4), Imbedding .EQMAC is issued when running the IVP because the profiles have not been updated for Double Byte. If PN17455 is not installed its possible to end up with modules containi only partial Double Byte maintenance installed. If PN18084 is not installed for VM, the saved segment may not be properly updated. ************************************************************************ * SECTION 4. S E R V I C E R E C O M M E N D A T I O N S * ************************************************************************ 1. YY/MM/DD PROBLEM: USERS AFFECTED: RECOMMENDATION: INSTALL XXXXXXX ON VOLID XXXX ************************************************************************ * SECTION 5. C R O S S P R O D U C T D E P E N D E N C I E S * ************************************************************************ THIS SECTION CONTAINS INFORMATION THAT IS DEPENDENT UPON ANOTHER PRODUCT OTHER THAN THIS SUBSET ID. 1. YY/MM/DD INTERDEPENDENT PRODUCT: PROBLEM: USERS AFFECTED: RECOMMENDATION: INSTALL XXXXXXX ON VOLID XXXX ************************************************************************ * I N F O R M A T I O N A L / D O C U M E N T A T I O N * * APARS FOLLOW (IF ANY) * ************************************************************************ --PTF INCLUDE LIST-- --PTF EXCLUDE LIST-- --PE APAR LIST--