FINAL POSTING: November 1999 File: @sc24274/README Member: FIX This document describes the APAR fix for ImagePlus VisualInfo for AS/400 (VI/400) Version 4.1 migration function. This apar ONLY AFFECTS WORKFOLDER APPLICATION FACILITY (WAF) V3R1M0 CUSTOMERS THAT DID NOT MIGRATE THEIR ENVIRONMENT PRIOR TO YEAR 2000. This readme and the associated fix is included in the fix package. The latest copy of this fix package can be obtained from the FTP site: 'ftp.software.ibm.com' under the following directory: 'as400/products/visualinfo/fixes/v410' in the file sc24274sf.bin. Please follow the special instructions for installing this fix before beginning your migration. NOTE: the objects must be restored into EKDIAM29xx as described belowed. SPECIAL INSTRUCTIONS 1. Create a save file in QGPL called: sc24274sf. 2. Download sc24274sf.bin to the save file in QGPL. 3. If EKDIAM2924 library exists on your AS/400 delete it. 4. Using the VisualInfo for AS/400 V4R1M0 installation/migration tapes or CD-ROM, perform the LODRUN as described in the VI/400 Planning and Installation Guide (GC34-4585-00). 5. Once the LODRUN has completed and you are at the EKDIAM menu, perform the following restore command before continuing with the migration. - RSTOBJ OBJ(*ALL) SAVLIB(@SC24274) DEV(*SAVF) SAVF(QGPL/SC24274SF) MBROPT(*ALL) RSTLIB(EKDIAM29xx) where xx is the feature code for your language, i.e., 2924. When the restore has completed you should receive the following message: 58 objects restored from @SC24274 to EKDIAM29xx. 6. Continue your migration as described in the VI/400 Planning and Installation Guide.